FCC ID ALH409000

800MHz Digital Transceiver

by Kenwood USA Corporation

Grantee Code: ALH   Product Code: 409000
Latest application date: 2010-11-24

FCC ID Device Details

FCC IDALH409000
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeALH
Product Code409000
Applicant BusinessKenwood USA Corporation 🇺🇸
Related Domains kenwoodusa.com
Equipment Class800MHz Digital Transceiver

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
806-824 MHzOriginal Equipment2010-11-24

Exhibits

DocumentTypeAvailableFile
NX-410-K2 Users ManualUsers Manual2010-11-24PDF 528.6 KB
NX-410-K2 Internal PhotosInternal Photos2010-11-24PDF 560.6 KB
NX-410-K2 External PhotosExternal Photos2010-11-24PDF 214.4 KB
NX-410-K2 Label and LocationID Label/Location Info2010-11-24PDF 355.4 KB
NX-410-K2 Testo Setup PhotosTest Setup Photos2010-11-24PDF 143.9 KB
FCC Certification Part 90Test Report2010-11-24PDF 408.1 KB
FCC Agent AuthorizationCover Letter(s)2010-11-24PDF 42.5 KB
FCC ConfidentialityCover Letter(s)2010-11-24PDF 39.6 KB
NX-410-K SAR ReportRF Exposure Info2010-11-24PDF 4.3 MB
NX-410-K2 RF Safety InfoRF Exposure Info2010-11-24PDF 491.5 KB

Application Information

Application IDph3zlbX9z2QWrs0wHAZxOA==
Final Action Date2010-11-24
Application PurposeOriginal Equipment
Applicant FRN0004356960
Model409000
Frequency Range806-824 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device Description800MHz Digital Transceiver
Responsible PartyJoel E. Berger, Staff Engineer, jberger@kenwoodusa.com , 678 474-4700
TCB Emailkarens@compliancetesting.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsPower output listed is at the antenna terminal on the device. Output Power Continuously Variable to 1 W. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations with a specific antenna(s), and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to the specific belt-clip for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 50% duty factor are - Part 90: Head: 1.52 W/kg; Body-worn: 3.91 W/kg.

Applications

Application IDDatePurpose
ph3zlbX9z2QWrs0wHAZxOA==2010-11-24Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
806-824 MHz31ppm4K00F2D9
806-824 MHz31ppm11K0F3E9
806-824 MHz31ppm8K30F1E9
806-824 MHz31ppm8K30F1D9
806-824 MHz31ppm8K30F7W9
806-824 MHz31ppm4K00F1E9
806-824 MHz31ppm4K00F1D9
806-824 MHz31ppm4K00F7W9
851-869 MHz31ppm16K0F3E9
851-869 MHz31ppm14K0F3E9
851-869 MHz31ppm11K0F3E9
851-869 MHz31ppm8K30F1E9
851-869 MHz31ppm8K30F1D9
851-869 MHz31ppm8K30F7W9
851-869 MHz31ppm4K00F1E9
851-869 MHz31ppm4K00F1D9
851-869 MHz31ppm4K00F7W9
851-869 MHz31ppm4K00F2D9

Grants

TCB Grant - Application ph3zlbX9z2QWrs0wHAZxOA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Compliance Testing, LLC
1724 S. Nevada Way
Mesa, AZ 85204
Date of Grant: 11/24/2010

Application Dated: 11/22/2010
Kenwood USA Corporation
3970 Johns Creek Court
Suite 100
Suwanee, GA 30024
 
Attention: Joel Berger , Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ALH409000
Name of Grantee:  Kenwood USA Corporation
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: 800MHz Digital Transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 806.0  -  824.0 3.0 1.0  PM 16K0F3E
90 806.0  -  824.0 3.0 1.0  PM 14K0F3E
90 806.0  -  824.0 3.0 1.0  PM 11K0F3E
90 806.0  -  824.0 3.0 1.0  PM 8K30F1E
90 806.0  -  824.0 3.0 1.0  PM 8K30F1D
90 806.0  -  824.0 3.0 1.0  PM 8K30F7W
90 806.0  -  824.0 3.0 1.0  PM 4K00F1E
90 806.0  -  824.0 3.0 1.0  PM 4K00F1D
90 806.0  -  824.0 3.0 1.0  PM 4K00F7W
90 806.0  -  824.0 3.0 1.0  PM 4K00F2D
90 851.0  -  869.0 3.0 1.0  PM 16K0F3E
90 851.0  -  869.0 3.0 1.0  PM 14K0F3E
90 851.0  -  869.0 3.0 1.0  PM 11K0F3E
90 851.0  -  869.0 3.0 1.0  PM 8K30F1E
90 851.0  -  869.0 3.0 1.0  PM 8K30F1D
90 851.0  -  869.0 3.0 1.0  PM 8K30F7W
90 851.0  -  869.0 3.0 1.0  PM 4K00F1E
90 851.0  -  869.0 3.0 1.0  PM 4K00F1D
90 851.0  -  869.0 3.0 1.0  PM 4K00F7W
90 851.0  -  869.0 3.0 1.0  PM 4K00F2D

Power output listed is at the antenna terminal on the device. Output Power Continuously Variable to 1 W. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations with a specific antenna(s), and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to the specific belt-clip for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 50% duty factor are - Part 90: Head: 1.52 W/kg; Body-worn: 3.91 W/kg.

EAS Grant - Application ph3zlbX9z2QWrs0wHAZxOA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Kenwood USA Corporation
3970 Johns Creek Court Suite 100
Suwanee, GA 30024
United States
  Date of Grant: 11/24/2010

Application Dated: 11/22/2010
 
Attention: Joel Berger , Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ALH409000
Name of Grantee:  Kenwood USA Corporation
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: 800MHz Digital Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 806.0  -  824.0 3.0 1.0  PM 16K0F3E
90 806.0  -  824.0 3.0 1.0  PM 14K0F3E
90 806.0  -  824.0 3.0 1.0  PM 11K0F3E
90 806.0  -  824.0 3.0 1.0  PM 8K30F1E
90 806.0  -  824.0 3.0 1.0  PM 8K30F1D
90 806.0  -  824.0 3.0 1.0  PM 8K30F7W
90 806.0  -  824.0 3.0 1.0  PM 4K00F1E
90 806.0  -  824.0 3.0 1.0  PM 4K00F1D
90 806.0  -  824.0 3.0 1.0  PM 4K00F7W
90 806.0  -  824.0 3.0 1.0  PM 4K00F2D
90 851.0  -  869.0 3.0 1.0  PM 16K0F3E
90 851.0  -  869.0 3.0 1.0  PM 14K0F3E
90 851.0  -  869.0 3.0 1.0  PM 11K0F3E
90 851.0  -  869.0 3.0 1.0  PM 8K30F1E
90 851.0  -  869.0 3.0 1.0  PM 8K30F1D
90 851.0  -  869.0 3.0 1.0  PM 8K30F7W
90 851.0  -  869.0 3.0 1.0  PM 4K00F1E
90 851.0  -  869.0 3.0 1.0  PM 4K00F1D
90 851.0  -  869.0 3.0 1.0  PM 4K00F7W
90 851.0  -  869.0 3.0 1.0  PM 4K00F2D

Power output listed is at the antenna terminal on the device. Output Power Continuously Variable to 1 W. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations with a specific antenna(s), and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to the specific belt-clip for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 50% duty factor are - Part 90: Head: 1.52 W/kg; Body-worn: 3.91 W/kg.



Mail To: