FCC ID ALH413800

Push-to-talk handheld radio for occupational use.

by Kenwood USA Corporation

Grantee Code: ALH   Product Code: 413800
Latest application date: 2014-04-23

FCC ID Device Details

FCC IDALH413800
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeALH
Product Code413800
Applicant BusinessKenwood USA Corporation 🇺🇸
Related Domains us.jvckenwood.com
Equipment ClassPush-to-talk handheld radio for occupational use.
Test FirmCompliance Testing, LLC

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-456 MHzClass II permissive change or modification of presently authorized equipment2014-04-23
450-456 MHzOriginal Equipment2010-12-02

Exhibits

DocumentTypeAvailableFile
TK-3312-1,TK-3317-1 Instruction ManualUsers Manual2010-12-02PDF 1.8 MB
TK-3312-1,TK-3317-1 Internal PhotosInternal Photos2010-12-02PDF 207.6 KB
TK-3312-1,TK-3317-1 External PhotosExternal Photos2010-12-02PDF 68.3 KB
TK-3312-1,TK-3317-1 Label and LocationID Label/Location Info2010-12-02PDF 129.7 KB
Test Setup PhotosTest Setup Photos2014-04-23PDF 123.3 KB
TK-3312-1,TK-3317-1 Test Setup PhotosTest Setup Photos2010-12-02PDF 430 KB
Test ReportTest Report2014-04-23PDF 224.8 KB
FCC Certification Part 90Test Report2010-12-02PDF 335.5 KB
Agent AuthCover Letter(s)2014-04-23PDF 45.9 KB
CIIPC LetterCover Letter(s)2014-04-23PDF 46.9 KB
CorrespondenceCover Letter(s)2014-04-23PDF 21.2 KB
FCC Agent AuthorizationCover Letter(s)2010-12-02PDF 42.5 KB
TK-3312-1,TK-3317-1 FCC ConfidentialityCover Letter(s)2010-12-02PDF 42.7 KB
TK-3312-1,TK-3317-1 FCC Justify LetterCover Letter(s)2010-12-02PDF 28.8 KB
RF Exposure infoRF Exposure Info2014-04-23PDF 2.5 MB
SAR PhotosRF Exposure Info2010-12-02PDF 2.8 MB
SAR Plots 1 of 2RF Exposure Info2010-12-02PDF 2.4 MB
SAR Plots 2 of 2RF Exposure Info2010-12-02PDF 2.5 MB
SAR ReportRF Exposure Info2010-12-02PDF 2.4 MB

Application Information

Application IDcanDoxj+YGSZCKaEic0xLQ==
Final Action Date2014-04-23
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0004356960
Model413800
Frequency Range450-456 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionPush-to-talk handheld radio for occupational use.
Responsible PartyAngelina Seay, Regulatory Support Engineer, aseay@us.jvckenwood.com , 6784744701
Test FirmSteve Schafer, Compliance Testing, LLC, steves@ComplianceTesting.com , 4809263100
TCB Emailamandar@compliancetesting.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsClass II Permissive Change to antennas and battery. Output Power Continuously Variable to 1W. Power output listed is at the antenna terminal on the device. This transmitter has been tested for SAR compliance in Push-to-Talk and Body-Worn operating configurations with specific antennas, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to the specific belt-clips for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported head and body-worn accessory SAR values at 50% duty factor across all filings under this FCC ID are 4.68 W/kg and: 7.62 W/kg., respectively. The highest reported SAR values at 50% duty factor for head and body-worn accessory in this C2PC filing are 3.26 W/kg and 5.24 W/kg, respectively.

Applications

Application IDDatePurpose
canDoxj+YGSZCKaEic0xLQ==2014-04-23Class II permissive change or modification of presently authorized equipment
rzyX7+LHhSha0c/tieQIdA==2010-12-02Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
450-520 MHz52.5ppm16K0F3E9EF
450-456 MHz52.5ppm11K0F3E74EF
450-456 MHz52.5ppm16K0F3E74EF
450-520 MHz52.5ppm11K0F3E9EF
454-460 MHz52.5ppm16K0F3E22EF
454-460 MHz52.5ppm11K0F3E22EF
470-512 MHz52.5ppm11K0F3E22
470-512 MHz52.5ppm16K0F3E22
470-520 MHz52.5ppm16K0F3E74
470-520 MHz52.5ppm11K0F3E74

Grants

TCB Grant - Application rzyX7+LHhSha0c/tieQIdA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Compliance Testing, LLC
1724 S. Nevada Way
Mesa, AZ 85204
Date of Grant: 12/02/2010

Application Dated: 11/29/2010
Kenwood USA Corporation
3970 Johns Creek Court
Suite 100
Suwanee, GA 30024
 
Attention: Joel Berger , Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ALH413800
Name of Grantee:  Kenwood USA Corporation
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: UHF FM Transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 22 454.0  -  460.0 5.0 2.5  PM 11K0F3E
EF 22 454.0  -  460.0 5.0 2.5  PM 16K0F3E
22 470.0  -  512.0 5.0 2.5  PM 11K0F3E
22 470.0  -  512.0 5.0 2.5  PM 16K0F3E
EF 74 450.0  -  456.0 5.0 2.5  PM 11K0F3E
EF 74 450.0  -  456.0 5.0 2.5  PM 16K0F3E
74 470.0  -  520.0 5.0 2.5  PM 11K0F3E
74 470.0  -  520.0 5.0 2.5  PM 16K0F3E
EF 90 450.0  -  520.0 5.0 2.5  PM 11K0F3E
EF 90 450.0  -  520.0 5.0 2.5  PM 16K0F3E

Output Power Continuously Variable to 1W. Power output listed is at the antenna terminal on the device. This transmitter has been tested for SAR compliance in Push-to-Talk and Body-Worn operating configurations with specific antennas, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to the specific belt-clips for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 50% duty factor are - Head: 4.68 W/kg; Body-worn: 7.62 W/kg.

EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

EAS Grant - Application rzyX7+LHhSha0c/tieQIdA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Kenwood USA Corporation
3970 Johns Creek Court Suite 100
Suwanee, GA 30024
United States
  Date of Grant: 12/02/2010

Application Dated: 11/29/2010
 
Attention: Joel Berger , Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ALH413800
Name of Grantee:  Kenwood USA Corporation
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: UHF FM Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 22 454.0  -  460.0 5.0 2.5  PM 11K0F3E
EF 22 454.0  -  460.0 5.0 2.5  PM 16K0F3E
22 470.0  -  512.0 5.0 2.5  PM 11K0F3E
22 470.0  -  512.0 5.0 2.5  PM 16K0F3E
EF 74 450.0  -  456.0 5.0 2.5  PM 11K0F3E
EF 74 450.0  -  456.0 5.0 2.5  PM 16K0F3E
74 470.0  -  520.0 5.0 2.5  PM 11K0F3E
74 470.0  -  520.0 5.0 2.5  PM 16K0F3E
EF 90 450.0  -  520.0 5.0 2.5  PM 11K0F3E
EF 90 450.0  -  520.0 5.0 2.5  PM 16K0F3E

Output Power Continuously Variable to 1W. Power output listed is at the antenna terminal on the device. This transmitter has been tested for SAR compliance in Push-to-Talk and Body-Worn operating configurations with specific antennas, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to the specific belt-clips for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 50% duty factor are - Head: 4.68 W/kg; Body-worn: 7.62 W/kg.


EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

TCB Grant - Application canDoxj+YGSZCKaEic0xLQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Compliance Testing, LLC
1724 S. Nevada Way
Mesa, AZ 85204
Date of Grant: 04/23/2014

Application Dated: 04/22/2014
Kenwood USA Corporation
5000 Research Ct
Suite 700
Suwanee, GA 30024
 
Attention: Angelina Seay , Regulatory Support Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ALH413800
Name of Grantee:  Kenwood USA Corporation
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Push-to-talk handheld radio for occupational use.
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22 470.0  -  512.0 5.0 2.5  PM 11K0F3E
22 470.0  -  512.0 5.0 2.5  PM 16K0F3E
EF 74 450.0  -  456.0 5.0 2.5  PM 11K0F3E
EF 74 450.0  -  456.0 5.0 2.5  PM 16K0F3E
74 470.0  -  520.0 5.0 2.5  PM 16K0F3E
EF 90 450.0  -  520.0 5.0 2.5  PM 11K0F3E
74 470.0  -  520.0 5.0 2.5  PM 11K0F3E
EF 22 454.0  -  460.0 5.0 2.5  PM 11K0F3E
EF 22 454.0  -  460.0 5.0 2.5  PM 16K0F3E

Class II Permissive Change to antennas and battery. Output Power Continuously Variable to 1W. Power output listed is at the antenna terminal on the device. This transmitter has been tested for SAR compliance in Push-to-Talk and Body-Worn operating configurations with specific antennas, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to the specific belt-clips for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information.

The highest reported head and body-worn accessory SAR values at 50% duty factor across all filings under this FCC ID are 4.68 W/kg and: 7.62 W/kg., respectively. The highest reported SAR values at 50% duty factor for head and body-worn accessory in this C2PC filing are 3.26 W/kg and 5.24 W/kg, respectively.


EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

EAS Grant - Application canDoxj+YGSZCKaEic0xLQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Kenwood USA Corporation
5000 Research Ct Suite 700
Suwanee, GA 30024
United States
  Date of Grant: 04/23/2014

Application Dated: 04/22/2014
 
Attention: Angelina Seay , Regulatory Support Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ALH413800
Name of Grantee:  Kenwood USA Corporation
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Push-to-talk handheld radio for occupational use.
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22 470.0  -  512.0 5.0 2.5  PM 11K0F3E
22 470.0  -  512.0 5.0 2.5  PM 16K0F3E
EF 74 450.0  -  456.0 5.0 2.5  PM 11K0F3E
EF 74 450.0  -  456.0 5.0 2.5  PM 16K0F3E
74 470.0  -  520.0 5.0 2.5  PM 16K0F3E
EF 90 450.0  -  520.0 5.0 2.5  PM 11K0F3E
74 470.0  -  520.0 5.0 2.5  PM 11K0F3E
EF 22 454.0  -  460.0 5.0 2.5  PM 11K0F3E
EF 22 454.0  -  460.0 5.0 2.5  PM 16K0F3E

Class II Permissive Change to antennas and battery. Output Power Continuously Variable to 1W. Power output listed is at the antenna terminal on the device. This transmitter has been tested for SAR compliance in Push-to-Talk and Body-Worn operating configurations with specific antennas, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to the specific belt-clips for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information.

The highest reported head and body-worn accessory SAR values at 50% duty factor across all filings under this FCC ID are 4.68 W/kg and: 7.62 W/kg., respectively. The highest reported SAR values at 50% duty factor for head and body-worn accessory in this C2PC filing are 3.26 W/kg and 5.24 W/kg, respectively.


EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

Mail To: