FCC ID ALH460300
Licensed Non-Broadcast Transmitter Held to Face
by Kenwood USA Corporation
Grantee Code: ALH Product Code: 460300
Latest application date: 2013-09-24
FCC ID Device Details
| FCC ID | ALH460300 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | ALH |
| Product Code | 460300 |
| Applicant Business | Kenwood USA Corporation 🇺🇸 |
| Related Domains | |
| Equipment Class | Licensed Non-Broadcast Transmitter Held to Face |
| Test Firm | Compliance Testing, LLC |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 440-480 MHz | Original Equipment | 2013-09-24 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Instruction Manual | Users Manual | 2013-09-24 | PDF 3.9 MB |
| Operating Instructions | Users Manual | 2013-09-24 | PDF 531.5 KB |
| RF Exposure Information | Users Manual | 2013-09-24 | PDF 16.2 KB |
| Internal Photos | Internal Photos | 2013-09-24 | PDF 502 KB |
| External Photos | External Photos | 2013-09-24 | PDF 342.8 KB |
| Label and Location | ID Label/Location Info | 2013-09-24 | PDF 248.2 KB |
| Test Photos | Test Setup Photos | 2013-09-24 | PDF 298.6 KB |
| Part 90 Test Report | Test Report | 2013-09-24 | PDF 518 KB |
| SAR Test Report | Test Report | 2013-09-24 | PDF 2 MB |
| Agent Auth | Cover Letter(s) | 2013-09-24 | PDF 45.9 KB |
| Confidentiality Request | Cover Letter(s) | 2013-09-24 | PDF 38.3 KB |
| Correspondence | Cover Letter(s) | 2013-09-24 | PDF 90.2 KB |
| Justify Letter | Cover Letter(s) | 2013-09-24 | PDF 94.6 KB |
Application Information
| Application ID | 72UUrZIPk8yRAwRycGd2Mg== |
|---|---|
| Final Action Date | 2013-09-24 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0004356960 |
| Model | 460300 |
| Frequency Range | 440-480 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | Licensed Non-Broadcast Transmitter Held to Face |
| Responsible Party | Joel E. Berger, Staff Engineer, jberger@kenwoodusa.com |
| Test Firm | Steve Schafer, Compliance Testing, LLC, steves@ComplianceTesting.com |
| TCB Email | amandar@compliancetesting.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is at the antenna terminal on the device. Output Power is continuously variable 1.5W to 0.5W. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations with a specific antenna(s), and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50%. Body-worn operations are restricted belt-clips, holsters or similar accessories that have no metallic component in the assembly. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 50% duty factor are - Head: 0.31 W/kg; Body-worn: 0.94 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 72UUrZIPk8yRAwRycGd2Mg== | 2013-09-24 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application 72UUrZIPk8yRAwRycGd2Mg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Compliance Testing, LLC 1724 S. Nevada Way Mesa, AZ 85204 |
Date of Grant: 09/24/2013 Application Dated: 09/24/2013 |
| Kenwood USA Corporation |
| 3970 Johns Creek Court |
| Suite 100 |
| Suwanee, GA 30024 |
| Attention: Joel Berger , Staff Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ALH460300 |
| Name of Grantee: | Kenwood USA Corporation |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Licensed Non-Broadcast Transmitter Held to Face |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF | 90 | 440.0 - 480.0 | 1.5 | 2.5 PM | 11K0F3E |
| Power output listed is at the antenna terminal on the device. Output Power is continuously variable 1.5W to 0.5W. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations with a specific antenna(s), and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50%. Body-worn operations are restricted belt-clips, holsters or similar accessories that have no metallic component in the assembly. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 50% duty factor are - Head: 0.31 W/kg; Body-worn: 0.94 W/kg. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
EAS Grant - Application 72UUrZIPk8yRAwRycGd2Mg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Kenwood USA Corporation 3970 Johns Creek Court Suite 100 Suwanee, GA 30024 United States |
Date of Grant: 09/24/2013 Application Dated: 09/24/2013 |
| Attention: Joel Berger , Staff Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ALH460300 |
| Name of Grantee: | Kenwood USA Corporation |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Licensed Non-Broadcast Transmitter Held to Face |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF | 90 | 440.0 - 480.0 | 1.5 | 2.5 PM | 11K0F3E |
| Power output listed is at the antenna terminal on the device. Output Power is continuously variable 1.5W to 0.5W. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations with a specific antenna(s), and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50%. Body-worn operations are restricted belt-clips, holsters or similar accessories that have no metallic component in the assembly. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 50% duty factor are - Head: 0.31 W/kg; Body-worn: 0.94 W/kg. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
| Mail To: |