FCC ID AMW4960

4960

by Uniden America Corporation

Grantee Code: AMW   Product Code: 4960
Latest application date: 2002-02-26

FCC ID Device Details

FCC IDAMW4960
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeAMW
Product Code4960
Applicant BusinessUniden America Corporation 🇺🇸
Related Domains uniden.com ms29.hinet.net
Equipment Class4960
Test FirmElectronics Testing Center, Taiwan

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2002-02-26
2402.88-2479.75 MHzOriginal Equipment2001-11-29

Exhibits

DocumentTypeAvailableFile
USER MANUALUsers Manual2002-02-26PDF 301 KB
Users ManualUsers Manual2001-11-29PDF 301 KB
INTERNAL PHOTOSInternal Photos2002-02-26PDF 1.3 MB
EUT Internal PhotosInternal Photos2001-11-29PDF 1.3 MB
EXTERNAL PHOTOSExternal Photos2002-02-26PDF 417.5 KB
EUT External PhotosExternal Photos2001-11-29PDF 417.5 KB
ID LABELID Label/Location Info2002-02-26PDF 77.5 KB
FCC ID Label Metadata onlyID Label/Location Info2001-11-29PDF 77.5 KB
FCC ID Label and InformationID Label/Location Info2001-11-29PDF 77.5 KB
Block DiagramBlock Diagram2001-11-29PDF 12.1 KB
SchematicsSchematics2001-11-29PDF 87 KB
OPERATION DESCRIPTIONOperational Description2002-02-26PDF 9.3 KB
Operational DescriptionOperational Description2001-11-29PDF 218.3 KB
SETUP PHOTOSTest Setup Photos2002-02-26PDF 509.6 KB
Test Setup PhotosTest Setup Photos2001-11-29PDF 509.6 KB
TEST REPORTTest Report2002-02-26PDF 4 MB
Test Report Metadata onlyTest Report2001-11-29PDF 4 MB
Test Report Part 1Test Report2001-11-29PDF 689.7 KB
Test Report Part 2Test Report2001-11-29PDF 3.3 MB
Test Report Part 3 of Duty CycleTest Report2001-11-29PDF 1.7 MB
AUTHORIZATION LETTERCover Letter(s)2002-02-26PDF 56.1 KB
Authorization LetterCover Letter(s)2002-02-26PDF 22.5 KB
Confidential LetterCover Letter(s)2002-02-26PDF 213.9 KB
Authorization LetterCover Letter(s)2001-11-29PDF 43.4 KB
CRN 21841 Body Worn SAR at Middle ChannelRF Exposure Info2002-02-26PDF 63.2 KB
CRN 21841 Left head SAR at Middle ChannelRF Exposure Info2002-02-26PDF 113.3 KB
CRN 21841 Liquid ValidationRF Exposure Info2002-02-26PDF 8.8 KB
CRN 21841 Probe Cal reportRF Exposure Info2002-02-26PDF 995.3 KB
CRN 21841 Right Head SAR at Middle channelRF Exposure Info2002-02-26PDF 107.1 KB
CRN 21841 SAR System ValidationRF Exposure Info2002-02-26PDF 103.6 KB
MPE REPOERTRF Exposure Info2002-02-26PDF 521.5 KB
SAR REPORTRF Exposure Info2002-02-26PDF 2.5 MB
RF Exposure InformationRF Exposure Info2001-11-29PDF 41.9 KB
BLOCK DIAGRAM Metadata onlyBlock DiagramPDF 12.1 KB
CIRCUIT DIAGRAM Metadata onlySchematicsPDF 87 KB

Application Information

Application ID2JqtXAiL/HTETKOWKH/Z0w==
Final Action Date2002-02-26
Application PurposeOriginal Equipment
Applicant FRN0001657303
Model4960
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Responsible PartyPaul Roby, sroby@uniden.com , 817-858-3624
AgentJEFF JEFF JEFF, ELECTRONICS TESTING CENTER, TAIWAN, etcemi@ms29.hinet.net , 886-2-26023052
Technical ContactK. C. CHEN, ELECTRONICS TESTING CENTER, TAIWAN, etcemi@ms29.hinet.net , 886-2-26023052
Non-Technical ContactK. C. CHEN, ELECTRONICS TESTING CENTER, TAIWAN, etcemi@ms29.hinet.net , 886-2-26023052
Test FirmWill Yauo, Electronics Testing Center, Taiwan, willyauo@etc.org.tw , 886-3-3280026
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput is Conducted. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and positions the handset a minimum of 1.5 cm from the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Head: 0.06 W/kg; Body-worn: 0.02 W/kg

Applications

Application IDDatePurpose
2JqtXAiL/HTETKOWKH/Z0w==2002-02-26Original Equipment
2wCRdrZxfSHRpxbneBK4fg==2001-11-29Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.070790015C
2402.88-2479.75 MHz0.01115C
2404.62-2479.45 MHz0.0070815C68

Grants

TCB Grant - Application 2wCRdrZxfSHRpxbneBK4fg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 11/29/2001

Application Dated: 11/29/2001
Uniden America Corporation
6225 N. State Highway 161
Suite 300
Irving, TX 75038
 
Attention: Paul Roby

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AMW-4960
Name of Grantee:  Uniden America Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Cordless Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
68 15C 2404.62  -  2479.45 0.00708  
15C 2402.88  -  2479.75 0.011  

This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. This device must transmit with a source-based time-averaging duty factor not exceeding -- 10%. End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements.

68: This grant does not pertain to equipment approval requirements under Part 68.

EAS Grant - Application 2wCRdrZxfSHRpxbneBK4fg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Uniden America Corporation
6225 N. State Highway 161 Suite 300
Irving, TX 75038
United States
  Date of Grant: 11/29/2001

Application Dated: 11/29/2001
 
Attention: Paul Roby

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AMW-4960
Name of Grantee:  Uniden America Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Cordless Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
68 15C 2404.62  -  2479.45 0.00708  
15C 2402.88  -  2479.75 0.011  

This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. This device must transmit with a source-based time-averaging duty factor not exceeding -- 10%. End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements.


68: This grant does not pertain to equipment approval requirements under Part 68.

TCB Grant - Application 2JqtXAiL/HTETKOWKH/Z0w==

This application does not exist.

EAS Grant - Application 2JqtXAiL/HTETKOWKH/Z0w==

Mail To:
COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Uniden America Corporation
6225 N. State Highway 161 Suite 300
Irving, TX 75038
United States
  Date of Grant: 02/26/2002

Application Dated: 11/18/2001
 
Attention: Paul Roby

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AMW4960
Name of Grantee:  Uniden America Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes:
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.07079  

Output is Conducted. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and positions the handset a minimum of 1.5 cm from the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Head: 0.06 W/kg; Body-worn: 0.02 W/kg



Mail To:
WILL YAUO, MANAGER
ELECTRONICS TESTING CENTER, TAIWAN
NO. 34, LIN 5, DING FU TSUN, LINKOU HSIANG
TAIPEI HSIEN, 244
Taiwan