FCC ID AMWUP855
5.8GHz Digital CT with caller ID
by Uniden America Corporation
Grantee Code: AMW Product Code: UP855
Latest application date: 2007-06-26
FCC ID Device Details
| FCC ID | AMWUP855 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | AMW |
| Product Code | UP855 |
| Applicant Business | Uniden America Corporation 🇺🇸 |
| Related Domains | |
| Equipment Class | 5.8GHz Digital CT with caller ID |
| Test Firm | Timco Engineering, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5725.8-5848.9 MHz | Original Equipment | 2007-06-26 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users manual | Users Manual | 2007-06-26 | PDF 1.1 MB |
| Internal photos | Internal Photos | 2007-06-26 | PDF 583.9 KB |
| External photos | External Photos | 2007-06-26 | PDF 138.2 KB |
| Label sample and location | ID Label/Location Info | 2007-06-26 | PDF 416.5 KB |
| Base Powerline conducted test set up photo | Test Setup Photos | 2007-06-26 | PDF 396.9 KB |
| Base radiated emissions test set up photo | Test Setup Photos | 2007-06-26 | PDF 209.6 KB |
| Handset Powerline conducted test set up photo | Test Setup Photos | 2007-06-26 | PDF 259 KB |
| Handset Radiated emissions test set up photo | Test Setup Photos | 2007-06-26 | PDF 216.1 KB |
| Test report | Test Report | 2007-06-26 | PDF 253.7 KB |
| Request for confidentiality letter | Cover Letter(s) | 2007-06-26 | PDF 50.7 KB |
| SAR report | RF Exposure Info | 2007-06-26 | PDF 2.9 MB |
Application Information
| Application ID | R4qoyT+zW+jCfcClnL9omg== |
|---|---|
| Final Action Date | 2007-06-26 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0001657303 |
| Model | UP855 |
| Frequency Range | 5725.8-5848.9 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | 5.8GHz Digital CT with caller ID |
| Responsible Party | Renji Inuzuka, rinuzuka@uniden.com |
| Test Firm | Sid Sanders, Timco Engineering, Inc., tei@timcoengr.com |
| TCB Email | tei@timcoengr.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | EIRP output power is 0.117 W for the base-unit and 0.117 W for the handset. The antenna(s) used for the base-unit must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. This device must transmit with a source-based time-averaging duty factor of 25% as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. SAR compliance for body-worn operating configurations is limited to the specific belt-clips/holsters/accessories tested for this filing. The highest reported SAR values are: head 0.01 W/kg; body 0.25 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| R4qoyT+zW+jCfcClnL9omg== | 2007-06-26 | Original Equipment |
Grants
TCB Grant - Application R4qoyT+zW+jCfcClnL9omg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION | TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
| Timco Engineering, Inc. 849 NW State Road 45 <BR>P.O. Box 370, Newberry, FL 32669 | Date of Grant: 06/26/2007 Application Dated: 06/26/2007 |
| Uniden America Corporation |
| 3001 Gateway Drive |
| Suite 130 |
| Irving, TX 75063 |
| Attention: Renji Inuzuka |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | AMWUP855 |
| Name of Grantee: | Uniden America Corporation |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | 5.8GHz Digital CT with caller ID |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 68 | 15C | 5725.8 - 5848.9 | 0.117 |
| EIRP output power is 0.117 W for the base-unit and 0.117 W for the handset. The antenna(s) used for the base-unit must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. This device must transmit with a source-based time-averaging duty factor of 25% as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. SAR compliance for body-worn operating configurations is limited to the specific belt-clips/holsters/accessories tested for this filing. The highest reported SAR values are: head 0.01 W/kg; body 0.25 W/kg. |
| 68: | This grant does not pertain to equipment approval requirements under Part 68. |
EAS Grant - Application R4qoyT+zW+jCfcClnL9omg==
| COPY | FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION | COPY |
| Certification |
| Uniden America Corporation 3001 Gateway Drive Suite 130 Irving, TX 75063 United States | Date of Grant: 06/26/2007 Application Dated: 06/26/2007 |
| Attention: Renji Inuzuka |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | AMWUP855 |
| Name of Grantee: | Uniden America Corporation |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | 5.8GHz Digital CT with caller ID |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 68 | 15C | 5725.8 - 5848.9 | 0.117 |
| EIRP output power is 0.117 W for the base-unit and 0.117 W for the handset. The antenna(s) used for the base-unit must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. This device must transmit with a source-based time-averaging duty factor of 25% as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. SAR compliance for body-worn operating configurations is limited to the specific belt-clips/holsters/accessories tested for this filing. The highest reported SAR values are: head 0.01 W/kg; body 0.25 W/kg.
|
| 68: | This grant does not pertain to equipment approval requirements under Part 68. |
| Mail To: |
| EA465610 |