FCC ID APYHRO00027
GSM/GPRS Cellular Phone Transceiver
by Sharp Corporation
Grantee Code: APY Product Code: HRO00027
Latest application date: 2003-01-17
FCC ID Device Details
| FCC ID | APYHRO00027 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | APY |
| Product Code | HRO00027 |
| Applicant Business | Sharp Corporation 🇯🇵 |
| Related Domains | |
| Equipment Class | GSM/GPRS Cellular Phone Transceiver |
| Test Firm | Japan Quality Assurance Org. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1850.2-1909.8 MHz | Original Equipment | 2003-01-17 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual 1 of 2 | Users Manual | 2003-01-17 | PDF 2.1 MB |
| User Manual 2 of 2 | Users Manual | 2003-01-17 | PDF 1,003.2 KB |
| Internal Photos | Internal Photos | 2003-01-17 | PDF 393.9 KB |
| External Photos | External Photos | 2003-01-17 | PDF 208.2 KB |
| FCC ID label format and location | ID Label/Location Info | 2003-01-17 | PDF 845.4 KB |
| CRN 6942 Product specification | Operational Description | 2003-01-17 | PDF 56 KB |
| Part 24 Test setup photos | Test Setup Photos | 2003-01-17 | PDF 18.8 KB |
| Additional RF conducted Harmonics emission | Test Report | 2003-01-17 | PDF 477.2 KB |
| Additional RF conducted Spurious emission | Test Report | 2003-01-17 | PDF 201 KB |
| Part 24 Test report Metadata only | Test Report | 2003-01-17 | PDF 893.6 KB |
| Revised Part 24 test report | Test Report | 2003-01-17 | PDF 890.5 KB |
| SAR Test Report | RF Exposure Info | 2003-01-17 | PDF 1 MB |
| Request for confidentiality letter | Cover Letter(s) | 2003-01-17 | PDF 50.3 KB |
| Revised TCB Q and A | Cover Letter(s) | 2003-01-17 | PDF 45.6 KB |
| TCB Q and A Metadata only | Cover Letter(s) | 2003-01-17 | PDF 41.3 KB |
| CRN 6942 Duty Cycle verification plots | RF Exposure Info | 2003-01-17 | PDF 124.8 KB |
| Duty cycle spectrum plots | RF Exposure Info | 2003-01-17 | PDF 124.8 KB |
| SAR Data Plots | RF Exposure Info | 2003-01-17 | PDF 1 MB |
| SAR Diple calibration file | RF Exposure Info | 2003-01-17 | PDF 1,011.7 KB |
| SAR System Validation Plots | RF Exposure Info | 2003-01-17 | PDF 62.8 KB |
| SAR probe calibration file | RF Exposure Info | 2003-01-17 | PDF 1.6 MB |
| Block Diagram Metadata only | Block Diagram | PDF 53.2 KB | |
| Schematic Diagram Metadata only | Schematics | PDF 642 KB | |
| Operational Description Metadata only | Operational Description | PDF 41.3 KB | |
| Tune up Procedure Metadata only | Parts List/Tune Up Info | PDF 18.6 KB | |
| Tune up procedures Metadata only | Parts List/Tune Up Info | PDF 18.6 KB |
Application Information
| Application ID | uLU4xVMGX8U4zlXmgg7Y3A== |
|---|---|
| Final Action Date | 2003-01-17 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0005810866 |
| Model | HRO00027 |
| Frequency Range | 1850.2-1909.8 MHz |
| Equipment Class | PCE - PCS Licensed Transmitter held to ear |
| Device Description | GSM/GPRS Cellular Phone Transceiver |
| Responsible Party | Taihei Ohtsuka, Division Manager, Head of Quality promotion div., fcc-contact@sharp.co.jp |
| Test Firm | Katsumi Nishii, Japan Quality Assurance Org., nishii-katsumi@jqa.jp |
| TCB Email | mkuo@ccsemc.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power is EIRP. This device contains 900 MHz and 1800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. This device was tested with a 1.5 cm device-to-body spacing gap and was not tested with any body-worn accessories made by Sharp or any other manufacturer. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 0.931 W/kg; Body-worn: 0.251 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| uLU4xVMGX8U4zlXmgg7Y3A== | 2003-01-17 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application uLU4xVMGX8U4zlXmgg7Y3A==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 01/17/2003 Application Dated: 01/17/2003 |
| Sharp Corporation |
| 1 Takumi-cho, Sakai-ku, Sakai City |
| Osaka, 590-8522 Japan |
| Attention: Taihei Ohtsuka , Division Manager, Head of Quality promotion div. |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | APYHRO00027 |
| Name of Grantee: | Sharp Corporation |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | GSM/GPRS Cellular Phone Transceiver |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 1.102 | 2.5 PM | 300KGXW |
| Power is EIRP. This device contains 900 MHz and 1800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. This device was tested with a 1.5 cm device-to-body spacing gap and was not tested with any body-worn accessories made by Sharp or any other manufacturer. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 0.931 W/kg; Body-worn: 0.251 W/kg. |
EAS Grant - Application uLU4xVMGX8U4zlXmgg7Y3A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Sharp Corporation 1 Takumi-cho, Sakai-ku, Sakai City Osaka, 590-8522 Japan |
Date of Grant: 01/17/2003 Application Dated: 01/17/2003 |
| Attention: Taihei Ohtsuka , Division Manager, Head of Quality promotion div. |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | APYHRO00027 |
| Name of Grantee: | Sharp Corporation |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | GSM/GPRS Cellular Phone Transceiver |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 1.102 | 2.5 PM | 300KGXW |
| Power is EIRP. This device contains 900 MHz and 1800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. This device was tested with a 1.5 cm device-to-body spacing gap and was not tested with any body-worn accessories made by Sharp or any other manufacturer. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 0.931 W/kg; Body-worn: 0.251 W/kg. |
| Mail To: |