FCC ID APYHRO00029
1900MHz GSM/GPRS Cellular Phone
by Sharp Corporation
Grantee Code: APY Product Code: HRO00029
Latest application date: 2003-03-24
FCC ID Device Details
| FCC ID | APYHRO00029 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | APY |
| Product Code | HRO00029 |
| Applicant Business | Sharp Corporation 🇯🇵 |
| Related Domains | |
| Equipment Class | 1900MHz GSM/GPRS Cellular Phone |
| Test Firm | Japan Quality Assurance Org. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1850.2-1909.8 MHz | Original Equipment | 2003-03-24 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2003-03-24 | PDF 1.8 MB |
| Internal Photos | Internal Photos | 2003-03-24 | PDF 107.6 KB |
| External Photos | External Photos | 2003-03-24 | PDF 94.8 KB |
| FCC ID labe format and location | ID Label/Location Info | 2003-03-24 | PDF 101.5 KB |
| CRN 7827 Technical specification sheet | Operational Description | 2003-03-24 | PDF 8.1 KB |
| Product specification | Operational Description | 2003-03-24 | PDF 8.1 KB |
| Thoery of operation | Operational Description | 2003-03-24 | PDF 5.4 KB |
| Part 24 Test setup photo | Test Setup Photos | 2003-03-24 | PDF 15.8 KB |
| Part 24 Test report | Test Report | 2003-03-24 | PDF 790.6 KB |
| Part 24 additional test report | Test Report | 2003-03-24 | PDF 222.8 KB |
| SAR Main Test report | RF Exposure Info | 2003-03-24 | PDF 537.7 KB |
| Requst for confidentiality letter | Cover Letter(s) | 2003-03-24 | PDF 24.9 KB |
| CRN 7827 System validation plots | RF Exposure Info | 2003-03-24 | PDF 65.6 KB |
| CRN 7827 additinal SAR test to show second peak | RF Exposure Info | 2003-03-24 | PDF 116 KB |
| CRN 7827 attenuator and connector | RF Exposure Info | 2003-03-24 | PDF 87.5 KB |
| CRN 7872 additional SAR plots | RF Exposure Info | 2003-03-24 | PDF 1 MB |
| SAR Data plots | RF Exposure Info | 2003-03-24 | PDF 1.2 MB |
| SAR Dipole calibration data | RF Exposure Info | 2003-03-24 | PDF 1,011.7 KB |
| SAR Probe calibration data | RF Exposure Info | 2003-03-24 | PDF 1.1 MB |
| SAR System Validation plots | RF Exposure Info | 2003-03-24 | PDF 94.2 KB |
| Block Diagram B B Metadata only | Block Diagram | PDF 42.8 KB | |
| Block Diagram RF Metadata only | Block Diagram | PDF 122.6 KB | |
| Main Schematic Diagram Metadata only | Schematics | PDF 667.8 KB | |
| RF Key schematic Diagram Metadata only | Schematics | PDF 383.2 KB | |
| Alignment procedures Metadata only | Parts List/Tune Up Info | PDF 14 KB | |
| Parts list 1 of 4 Metadata only | Parts List/Tune Up Info | PDF 13.4 KB | |
| Parts list 2 of 4 Metadata only | Parts List/Tune Up Info | PDF 14.1 KB | |
| Parts list 3 of 4 Metadata only | Parts List/Tune Up Info | PDF 13.3 KB | |
| Parts list 4 of 4 Metadata only | Parts List/Tune Up Info | PDF 15.7 KB | |
| Tune up procedures Metadata only | Parts List/Tune Up Info | PDF 5.9 KB |
Application Information
| Application ID | V9bvo8bN9egFB5un9Ev0zg== |
|---|---|
| Final Action Date | 2003-03-24 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0005810866 |
| Model | HRO00029 |
| Frequency Range | 1850.2-1909.8 MHz |
| Equipment Class | PCE - PCS Licensed Transmitter held to ear |
| Device Description | 1900MHz GSM/GPRS Cellular Phone |
| Responsible Party | Taihei Ohtsuka, Division Manager, Head of Quality promotion div., fcc-contact@sharp.co.jp |
| Test Firm | Takaharu Hada, Japan Quality Assurance Org., hada-takaharu@jqa.jp |
| TCB Email | mkuo@ccsemc.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power is EIRP. This device contains 900 MHz and 1800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. This device was tested with a 1.5 cm device-to-body spacing gap and was not tested with any body-worn accessories made by Sharp or any other manufacturer. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 0.518 W/kg; Body-worn: 0.434 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| V9bvo8bN9egFB5un9Ev0zg== | 2003-03-24 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application V9bvo8bN9egFB5un9Ev0zg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 03/24/2003 Application Dated: 03/24/2003 |
| Sharp Corporation |
| 1 Takumi-cho, Sakai-ku, Sakai City |
| Osaka, 590-8522 Japan |
| Attention: Taihei Ohtsuka , Division Manager, Head of Quality promotion div. |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | APYHRO00029 |
| Name of Grantee: | Sharp Corporation |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | 1900MHz GSM/GPRS Cellular Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 1.514 | 2.5 PM | 313KGXW |
| Power is EIRP. This device contains 900 MHz and 1800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. This device was tested with a 1.5 cm device-to-body spacing gap and was not tested with any body-worn accessories made by Sharp or any other manufacturer. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 0.518 W/kg; Body-worn: 0.434 W/kg. |
EAS Grant - Application V9bvo8bN9egFB5un9Ev0zg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Sharp Corporation 1 Takumi-cho, Sakai-ku, Sakai City Osaka, 590-8522 Japan |
Date of Grant: 03/24/2003 Application Dated: 03/24/2003 |
| Attention: Taihei Ohtsuka , Division Manager, Head of Quality promotion div. |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | APYHRO00029 |
| Name of Grantee: | Sharp Corporation |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | 1900MHz GSM/GPRS Cellular Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 1.514 | 2.5 PM | 313KGXW |
| Power is EIRP. This device contains 900 MHz and 1800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. This device was tested with a 1.5 cm device-to-body spacing gap and was not tested with any body-worn accessories made by Sharp or any other manufacturer. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 0.518 W/kg; Body-worn: 0.434 W/kg. |
| Mail To: |