FCC ID APYHRO00060

Cellular Transceiver

by Sharp Corporation

Grantee Code: APY   Product Code: HRO00060
Latest application date: 2007-08-01

FCC ID Device Details

FCC IDAPYHRO00060
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeAPY
Product CodeHRO00060
Applicant BusinessSharp Corporation 🇯🇵
Related Domains sharp.co.jp
Equipment ClassCellular Transceiver
Test FirmJapan Quality Assurance Org.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.2-1909.8 MHzOriginal Equipment2007-08-01
2402-2480 MHzOriginal Equipment2007-08-01

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2007-09-15PDF 1.7 MB
User Manual logoUsers Manual2007-09-15PDF 75.5 KB
Internal PhotosInternal Photos2007-09-15PDF 282.2 KB
External PhotosExternal Photos2007-09-15PDF 205.4 KB
LabelID Label/Location Info2007-08-01PDF 88 KB
SAR Setup PhotosTest Setup Photos2007-09-15PDF 253.5 KB
Setup PhotosTest Setup Photos2007-09-15PDF 197.6 KB
Setup PhotosTest Setup Photos2007-09-15PDF 378.8 KB
ReportTest Report2007-08-01PDF 768.5 KB
ReportTest Report2007-08-01PDF 1.1 MB
FCC ID Visibility DeclarationCover Letter(s)2007-08-01PDF 16 KB
Model DescriptionCover Letter(s)2007-08-01PDF 13 KB
Request for ConfidentialityCover Letter(s)2007-08-01PDF 43.4 KB
AntennaParts List/Tune Up Info2007-08-01PDF 661.4 KB
AntennaParts List/Tune Up Info2007-08-01PDF 69.6 KB
SAR ReportRF Exposure Info2007-08-01PDF 327.6 KB
SAR attachment 1RF Exposure Info2007-08-01PDF 82.6 KB
SAR attachment 2RF Exposure Info2007-08-01PDF 518 KB
SAR attachment 3RF Exposure Info2007-08-01PDF 1.3 MB
SAR attachment 4RF Exposure Info2007-08-01PDF 1.3 MB

Application Information

Application IDwSnXXHAbuThchASqm6K8cQ==
Final Action Date2007-08-01
Application PurposeOriginal Equipment
Applicant FRN0005810866
ModelHRO00060
Frequency Range1850.2-1909.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionCellular Transceiver
Responsible PartyMasaaki Nishikawa, Vice President, Head of Quality Promotion Unit, nishikawa-masaaki@sharp.co.jp , 81 6 6625 1197
Test FirmKatsumi Nishii, Japan Quality Assurance Org., nishii-katsumi@jqa.jp , 81-727-29-2243
TCB Emailmkuo@ccsemc.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Short-Term Confidentiality Date09/15/2007
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput listed is EIRP. This device was tested with a 1.5 cm device-to-body spacing gap and was not tested with any body-worn accessories made by Sharp or any other manufacturer. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for single- and co-transmit configurations for this FCC ID are: Head: 0.417 W/kg; Body: 0.462 W/kg. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.

Applications

Application IDDatePurpose
wSnXXHAbuThchASqm6K8cQ==2007-08-01Original Equipment
sCxwEB6Q5RXZ0ungHtJGSg==2007-08-01Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
1850.2-1909.8 MHz0.7762.5ppm247KGXW24EBC
1850.2-1909.8 MHz0.6522.5ppm245KG7W24EBC
2402-2480 MHz0.001180015C

Grants

TCB Grant - Application wSnXXHAbuThchASqm6K8cQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 08/01/2007

Application Dated: 08/01/2007
Sharp Corporation
22-22 Nagaike-cho, Abeno-ku
Quality Promotion Unit
Osaka, 545-8522
Japan
 
Attention: Masaaki Nishikawa , Vice President, Head of Quality Promotion Unit

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  APYHRO00060
Name of Grantee:  Sharp Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Cellular Transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 24E 1850.2  -  1909.8 0.776 2.5  PM 247KGXW
BC 24E 1850.2  -  1909.8 0.652 2.5  PM 245KG7W

Output listed is EIRP. This device was tested with a 1.5 cm device-to-body spacing gap and was not tested with any body-worn accessories made by Sharp or any other manufacturer. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for single- and co-transmit configurations for this FCC ID are: Head: 0.417 W/kg; Body: 0.462 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application wSnXXHAbuThchASqm6K8cQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sharp Corporation
22-22 Nagaike-cho, Abeno-ku Quality Promotion Unit
Osaka, 545-8522
Japan
  Date of Grant: 08/01/2007

Application Dated: 08/01/2007
 
Attention: Masaaki Nishikawa , Vice President, Head of Quality Promotion Unit

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  APYHRO00060
Name of Grantee:  Sharp Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Cellular Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 24E 1850.2  -  1909.8 0.776 2.5  PM 247KGXW
BC 24E 1850.2  -  1909.8 0.652 2.5  PM 245KG7W

Output listed is EIRP. This device was tested with a 1.5 cm device-to-body spacing gap and was not tested with any body-worn accessories made by Sharp or any other manufacturer. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for single- and co-transmit configurations for this FCC ID are: Head: 0.417 W/kg; Body: 0.462 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To:


EA821512

TCB Grant - Application sCxwEB6Q5RXZ0ungHtJGSg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 08/01/2007

Application Dated: 08/01/2007
Sharp Corporation
22-22 Nagaike-cho, Abeno-ku
Quality Promotion Unit
Osaka, 545-8522
Japan
 
Attention: Masaaki Nishikawa , Vice President, Head of Quality Promotion Unit

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  APYHRO00060
Name of Grantee:  Sharp Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Cellular Transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00118  

Output power listed is conducted. This device is co-located in a PCS handset. End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements.

EAS Grant - Application sCxwEB6Q5RXZ0ungHtJGSg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sharp Corporation
22-22 Nagaike-cho, Abeno-ku Quality Promotion Unit
Osaka, 545-8522
Japan
  Date of Grant: 08/01/2007

Application Dated: 08/01/2007
 
Attention: Masaaki Nishikawa , Vice President, Head of Quality Promotion Unit

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  APYHRO00060
Name of Grantee:  Sharp Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Cellular Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00118  

Output power listed is conducted. This device is co-located in a PCS handset. End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements.



Mail To:


EA199642