FCC ID ATH2425131
5100 Series 380-470 MHz
by E F Johnson Company
Grantee Code: ATH Product Code: 2425131
Latest application date: 2006-10-31
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 380-470 MHz | Class II permissive change or modification of presently authorized equipment | 2006-10-31 |
| 380-470 MHz | Original Equipment | 2004-11-12 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Manual | Users Manual | 2004-11-12 | PDF 648.4 KB |
| Internal photos | Internal Photos | 2004-11-12 | PDF 3.7 MB |
| External photos | External Photos | 2004-11-12 | PDF 900.2 KB |
| FCC IDlabel info | ID Label/Location Info | 2004-11-12 | PDF 651.2 KB |
| Test report | Test Report | 2004-11-12 | PDF 545.7 KB |
| Frequency attestation | Attestation Statements | 2004-11-12 | PDF 150.6 KB |
| Agency | Cover Letter(s) | 2006-10-31 | PDF 83.3 KB |
| Description of Change Letter | Cover Letter(s) | 2006-10-31 | PDF 156.8 KB |
| Permissive Change Letter | Cover Letter(s) | 2006-10-31 | PDF 54.1 KB |
| POA | Cover Letter(s) | 2004-11-12 | PDF 151.5 KB |
| Request for confidentiality | Cover Letter(s) | 2004-11-12 | PDF 149.8 KB |
| RF Exposure SAR | RF Exposure Info | 2006-10-31 | PDF 2.2 MB |
| SAR | RF Exposure Info | 2004-11-12 | PDF 2.5 MB |
| SAR photos | RF Exposure Info | 2004-11-12 | PDF 1.6 MB |
| Schematics Metadata only | Schematics | PDF 571 KB | |
| Operational description Metadata only | Operational Description | PDF 128.4 KB | |
| Tune up Metadata only | Parts List/Tune Up Info | PDF 237.2 KB | |
| parts list Metadata only | Parts List/Tune Up Info | PDF 122 KB |
Application Information
| Application ID | e9wc0ic5sxy6r6LjP/jafA== |
|---|---|
| Final Action Date | 2006-10-31 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0004201521 |
| Model | 2425131 |
| Frequency Range | 380-470 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | 5100 Series 380-470 MHz |
| Responsible Party | Karthik Rangarajan, SR VP Engineering, krangarajan@efji.com |
| Technical Contact | Desmond Fraser, Rhein Tech, atcbinfo@rheintech.com |
| Test Firm | Rick McMurray, Rhein Tech Laboratories, Inc., FCCINFO@rheintech.com |
| TCB Email | hotline@americantcb.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is at the antenna connector. This transmitter operates with the antennas listed in the filing. This transmitter is restricted to the occupational/controlled environment and must operate at no more that a 50% duty cycle. SAR was evaluated for body worn and held-to-face operating modes. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories as tested in this filing or that contain no metallic component in the assembly and which provide at least 1.3 cm separation between the device and the users body. An rf exposure warning statement should be placed on the transmitter asshown in this filing. End-users of this device must have the knowledge to control their exposureconditions and/or duration to comply with Occupational /Controlled rf exposure limits and requirements. The highest reported SAR values are: body: 5.73W/kg at 50% duty cycle. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| e9wc0ic5sxy6r6LjP/jafA== | 2006-10-31 | Class II permissive change or modification of presently authorized equipment |
| MaYOgkETspEvnp4rzsyOBQ== | 2004-11-12 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application MaYOgkETspEvnp4rzsyOBQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 11/12/2004 Application Dated: 11/12/2004 |
| E F Johnson Company |
| 1440 Corporate Drive |
| Irving, TX 56093 |
| Attention: Karthik Rangarajan , SR VP Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ATH2425131 |
| Name of Grantee: | E F Johnson Company |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | 5100 Series 380-470 MHz |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 11K0F3E | |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 16K0F3E | |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 11K8F1E | |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 11K8F1D |
| Power output listed is at the antenna connector. This transmitter operates with the antennas listed in the filing. This transmitter is restricted to the occupational/controlled environment and must operate at no more that a 50% duty cycle. SAR was evaluated for body worn and held-to-face operating modes. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories as tested in this filing or that contain no metallic component in the assembly and which provide at least 1.3 cm separation between the device and the users body. An rf exposure warning statement should be placed on the transmitter as shown in this filing. End-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled rf exposure limits and requirements. The highest reported SAR values are: body: 5.73W/kg at 50% duty cycle. |
EAS Grant - Application MaYOgkETspEvnp4rzsyOBQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
E F Johnson Company 1440 Corporate Drive Irving, TX 56093 United States |
Date of Grant: 11/12/2004 Application Dated: 11/12/2004 |
| Attention: Karthik Rangarajan , SR VP Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ATH2425131 |
| Name of Grantee: | E F Johnson Company |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | 5100 Series 380-470 MHz |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 11K0F3E | |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 16K0F3E | |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 11K8F1E | |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 11K8F1D |
| Power output listed is at the antenna connector. This transmitter operates with the antennas listed in the filing. This transmitter is restricted to the occupational/controlled environment and must operate at no more that a 50% duty cycle. SAR was evaluated for body worn and held-to-face operating modes. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories as tested in this filing or that contain no metallic component in the assembly and which provide at least 1.3 cm separation between the device and the users body. An rf exposure warning statement should be placed on the transmitter as shown in this filing. End-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled rf exposure limits and requirements. The highest reported SAR values are: body: 5.73W/kg at 50% duty cycle. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 10/31/2006 Application Dated: 10/31/2006 |
| E F Johnson Company |
| 1440 Corporate Drive |
| Irving, TX 56093 |
| Attention: Karthik Rangarajan , SR VP Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ATH2425131 |
| Name of Grantee: | E F Johnson Company |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | 5100 Series 380-470 MHz |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 11K0F3E | |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 16K0F3E | |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 11K8F1E | |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 11K8F1D |
| Power output listed is at the antenna connector. This transmitter operates with the antennas listed in the filing. This transmitter is restricted to the occupational/controlled environment and must operate at no more that a 50% duty cycle. SAR was evaluated for body worn and held-to-face operating modes. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories as tested in this filing or that contain no metallic component in the assembly and which provide at least 1.3 cm separation between the device and the users body. An rf exposure warning statement should be placed on the transmitter asshown in this filing. End-users of this device must have the knowledge to control their exposureconditions and/or duration to comply with Occupational /Controlled rf exposure limits and requirements. The highest reported SAR values are: body: 5.73W/kg at 50% duty cycle. |
EAS Grant - Application e9wc0ic5sxy6r6LjP/jafA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
E F Johnson Company 1440 Corporate Drive Irving, TX 56093 United States |
Date of Grant: 10/31/2006 Application Dated: 10/31/2006 |
| Attention: Karthik Rangarajan , SR VP Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ATH2425131 |
| Name of Grantee: | E F Johnson Company |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | 5100 Series 380-470 MHz |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 11K0F3E | |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 16K0F3E | |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 11K8F1E | |
| 90 | 380.0 - 470.0 | 5.2 | 0.9 PM | 11K8F1D |
| Power output listed is at the antenna connector. This transmitter operates with the antennas listed in the filing. This transmitter is restricted to the occupational/controlled environment and must operate at no more that a 50% duty cycle. SAR was evaluated for body worn and held-to-face operating modes. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories as tested in this filing or that contain no metallic component in the assembly and which provide at least 1.3 cm separation between the device and the users body. An rf exposure warning statement should be placed on the transmitter asshown in this filing. End-users of this device must have the knowledge to control their exposureconditions and/or duration to comply with Occupational /Controlled rf exposure limits and requirements. The highest reported SAR values are: body: 5.73W/kg at 50% duty cycle. |
| Mail To: |