FCC ID AZ489FT4861

ASTRO SSE5000

by Motorola Solutions, Inc.

Grantee Code: AZ4   Product Code: 89FT4861
Latest application date: 2004-09-13

FCC ID Device Details

FCC IDAZ489FT4861
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeAZ4
Product Code89FT4861
Applicant BusinessMotorola Solutions, Inc. 🇺🇸
Related Domains motorolasolutions.com
Equipment ClassASTRO SSE5000
Test FirmMotorola

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-488 MHzClass II permissive change or modification of presently authorized equipment2004-09-13
450-488 MHzOriginal Equipment2003-08-01

Exhibits

DocumentTypeAvailableFile
Exhibit D Users Manual per 2 1033 c3Users Manual2003-08-01PDF 209.1 KB
Exhibit C Internal Photographs per 2 1033 c12Internal Photos2003-08-01PDF 203.7 KB
Exhibit C External Photographs per 2 1033 c12External Photos2003-08-01PDF 100.5 KB
Exhibit A ID Label and location per 2 1033 c2 and c11ID Label/Location Info2003-08-01PDF 23.6 KB
TEST REPORTTest Report2004-09-13PDF 340.5 KB
Exhibit E Test Measurement Report per 2 1033 c14Test Report2003-08-01PDF 309.2 KB
Statement of CertificationAttestation Statements2003-08-01PDF 8.2 KB
COVER LETTERCover Letter(s)2004-09-13PDF 17.5 KB
Cover LetterCover Letter(s)2003-08-01PDF 7.8 KB
Cover Letter Requesting ConfidentialityCover Letter(s)2003-08-01PDF 232.2 KB
Misc Tune Up Procedure ExhibitsParts List/Tune Up Info2003-08-01PDF 19.3 KB
RF Exposure Test Measurement ReportRF Exposure Info2003-08-01PDF 2.7 MB
Exhibit B Block Diagram per 2 1033 b5 Metadata onlyBlock DiagramPDF 30.8 KB
Exhibit B Schematics per 2 1033 c10 Metadata onlySchematicsPDF 1.4 MB
Exhibit B Operational Description per 2 1033 c 4 5 6 7 8 9 13 Metadata onlyOperational DescriptionPDF 60.3 KB

Application Information

Application IDsFgHTDV3YHWVbVDhu7KQww==
Final Action Date2004-09-13
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0003778479
Model89FT4861
Frequency Range450-488 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionASTRO SSE5000
Responsible PartyDeanna Zakharia, Regulatory Compliance Manager, deanna.zakharia@motorolasolutions.com , 9547234707
Test FirmWilliam Elliott, Motorola, FME001@motorolasolutions.com , 954-723-5480
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput is at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the antennas tested for this filing in Push-to-Talk and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. Grantee must coordinate with organizations using this device to ensure RF exposure requirements are met. The highest reported SAR values are - Face: 2.05 W/kg; Body-worn: 3.84 W/kg.

Applications

Application IDDatePurpose
sFgHTDV3YHWVbVDhu7KQww==2004-09-13Class II permissive change or modification of presently authorized equipment
+5XwE+7zdHZ4lVw5J5u+SQ==2003-08-01Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
450-488 MHz52ppm16K0F3E80, 9BK
450-488 MHz5216K0F3E80, 90, 90.21BK
450-488 MHz52ppm11K0F3E80, 9BK
450-488 MHz52ppm11K0F3E80, 90, 90.21BK
450-488 MHz52ppm8K10F1E80, 9BK
450-488 MHz52ppm8K10F1E80, 90, 90.21BK
450-488 MHz52ppm8K10F1D80, 9BK
450-488 MHz52ppm8K10F1D80, 90, 90.21BK
450-488 MHz52ppm20K0F1E80, 9BK
450-488 MHz52ppm20K0F1E80, 90, 90.21BK

Grants

TCB Grant - Application sFgHTDV3YHWVbVDhu7KQww==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 09/13/2004

Application Dated: 09/13/2004
Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
 
Attention: Deanna Zakharia , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT4861
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: ASTRO SSE5000
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BK 80, 90, 90.210 450.0  -  488.0 5.0 2.0   16K0F3E
BK 80, 90, 90.210 450.0  -  488.0 5.0 2.0  PM 11K0F3E
BK 80, 90, 90.210 450.0  -  488.0 5.0 2.0  PM 8K10F1E
BK 80, 90, 90.210 450.0  -  488.0 5.0 2.0  PM 8K10F1D
BK 80, 90, 90.210 450.0  -  488.0 5.0 2.0  PM 20K0F1E

Output is at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the antennas tested for this filing in Push-to-Talk and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. Grantee must coordinate with organizations using this device to ensure RF exposure requirements are met. The highest reported SAR values are - Face: 2.05 W/kg; Body-worn: 3.84 W/kg.

BK: The output power is continuously variable from the value listed in this entry to 40%-45% of the value listed.

EAS Grant - Application sFgHTDV3YHWVbVDhu7KQww==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
United States
  Date of Grant: 09/13/2004

Application Dated: 09/13/2004
 
Attention: Deanna Zakharia , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT4861
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: ASTRO SSE5000
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BK 80, 90, 90.210 450.0  -  488.0 5.0 2.0   16K0F3E
BK 80, 90, 90.210 450.0  -  488.0 5.0 2.0  PM 11K0F3E
BK 80, 90, 90.210 450.0  -  488.0 5.0 2.0  PM 8K10F1E
BK 80, 90, 90.210 450.0  -  488.0 5.0 2.0  PM 8K10F1D
BK 80, 90, 90.210 450.0  -  488.0 5.0 2.0  PM 20K0F1E

Output is at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the antennas tested for this filing in Push-to-Talk and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. Grantee must coordinate with organizations using this device to ensure RF exposure requirements are met. The highest reported SAR values are - Face: 2.05 W/kg; Body-worn: 3.84 W/kg.


BK: The output power is continuously variable from the value listed in this entry to 40%-45% of the value listed.

TCB Grant - Application +5XwE+7zdHZ4lVw5J5u+SQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Elite Electronic Engineering, Inc.
1516 Centre Circle
Downers Grove, IL 60515
Date of Grant: 08/01/2003

Application Dated: 08/01/2003
Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
 
Attention: Deanna Zakharia , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT4861
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: SSE 5000 Protable Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BK 80, 90 450.0  -  488.0 5.0 2.0  PM 16K0F3E
BK 80, 90 450.0  -  488.0 5.0 2.0  PM 11K0F3E
BK 80, 90 450.0  -  488.0 5.0 2.0  PM 8K10F1E
BK 80, 90 450.0  -  488.0 5.0 2.0  PM 8K10F1D
BK 80, 90 450.0  -  488.0 5.0 2.0  PM 20K0F1E

Output is at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the antennas tested for this filing in Push-to-Talk and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. Grantee must coordinate with organizations using this device to ensure RF exposure requirements are met. The highest reported SAR values are - Face: 2.05 W/kg; Body-worn: 3.84 W/kg.

BK: The output power is continuously variable from the value listed in this entry to 40%-45% of the value listed.

EAS Grant - Application +5XwE+7zdHZ4lVw5J5u+SQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
United States
  Date of Grant: 08/01/2003

Application Dated: 08/01/2003
 
Attention: Deanna Zakharia , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT4861
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: SSE 5000 Protable Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BK 80, 90 450.0  -  488.0 5.0 2.0  PM 16K0F3E
BK 80, 90 450.0  -  488.0 5.0 2.0  PM 11K0F3E
BK 80, 90 450.0  -  488.0 5.0 2.0  PM 8K10F1E
BK 80, 90 450.0  -  488.0 5.0 2.0  PM 8K10F1D
BK 80, 90 450.0  -  488.0 5.0 2.0  PM 20K0F1E

Output is at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the antennas tested for this filing in Push-to-Talk and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. Grantee must coordinate with organizations using this device to ensure RF exposure requirements are met. The highest reported SAR values are - Face: 2.05 W/kg; Body-worn: 3.84 W/kg.


BK: The output power is continuously variable from the value listed in this entry to 40%-45% of the value listed.

Mail To: