FCC ID AZ489FT4866
HAND HELD PORTABLE 2-WAY R4ADIO
by Motorola Solutions, Inc.
Grantee Code: AZ4 Product Code: 89FT4866
Latest application date: 2004-09-13
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 450 MHz | Original Equipment | 2004-09-13 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| USERS MANUAL | Users Manual | 2004-10-28 | PDF 2.9 MB |
| INTERNAL PHOTOS | Internal Photos | 2004-10-28 | PDF 715.3 KB |
| EXTERNAL PHOTOS | External Photos | 2004-10-28 | PDF 1.8 MB |
| ID LABEL SAMPLE | ID Label/Location Info | 2004-09-13 | PDF 106.9 KB |
| TEST REPORT 1 | Test Report | 2004-09-13 | PDF 413.7 KB |
| TEST REPORT 2 | Test Report | 2004-09-13 | PDF 413.7 KB |
| CONFIDENTIALITY LETTER | Cover Letter(s) | 2004-09-13 | PDF 78.8 KB |
| RF EXPOSURE | RF Exposure Info | 2004-09-13 | PDF 210.7 KB |
| SAR REPORT | RF Exposure Info | 2004-09-13 | PDF 452.9 KB |
| SCHEMATICS Metadata only | Schematics | PDF 590.3 KB | |
| OPERATIONAL DESCRIPTION 1 Metadata only | Operational Description | PDF 116.8 KB | |
| OPERATIONAL DESCRIPTION 2 Metadata only | Operational Description | PDF 141.9 KB | |
| PARTS LIST Metadata only | Parts List/Tune Up Info | PDF 114.3 KB |
Application Information
| Application ID | HF6v2PvT1XmW9+VVaN6AiQ== |
|---|---|
| Final Action Date | 2004-09-13 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0003778479 |
| Model | 89FT4866 |
| Frequency Range | 450 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | HAND HELD PORTABLE 2-WAY R4ADIO |
| Responsible Party | Deanna Zakharia, Regulatory Compliance Manager, deanna.zakharia@motorolasolutions.com |
| Test Firm | William Elliott, Motorola, FME001@motorolasolutions.com |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Short-Term Confidentiality Date | 10/28/2004 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. Output at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the three antennas tested for this filing in Push-to-Talk and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 4.54 mW/kg; Body-worn: 6.41 mW/kg accounting for a 50% duty cycle. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| HF6v2PvT1XmW9+VVaN6AiQ== | 2004-09-13 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application HF6v2PvT1XmW9+VVaN6AiQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 09/13/2004 Application Dated: 09/13/2004 |
| Motorola Solutions, Inc. |
| 8000 West Sunrise Blvd |
| Ft Lauderdale, FL 33322 |
| Attention: Deanna Zakharia , Regulatory Compliance Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | AZ489FT4866 |
| Name of Grantee: | Motorola Solutions, Inc. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | HAND HELD PORTABLE 2-WAY R4ADIO |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BE | 80, 90, 90.210 | 450.0 - 520.0 | 6.0 | 2.0 PM | 16K0F3E |
| BE | 80, 90, 90.210 | 450.0 - 450.0 | 6.0 | 2.0 PM | 11K0F3E |
| BE | 80, 90, 90.210 | 450.0 - 520.0 | 6.0 | 2.0 PM | 8K10F1E |
| BE | 80, 90, 90.210 | 450.0 - 520.0 | 6.0 | 2.0 PM | 8K10F1D |
| BE | 80, 90, 90.210 | 450.0 - 520.0 | 6.0 | 2.0 PM | 20K0F1E |
| Power listed is conducted. Output at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the three antennas tested for this filing in Push-to-Talk and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 4.54 mW/kg; Body-worn: 6.41 mW/kg accounting for a 50% duty cycle. |
| BE: | The output power is continuously variable from the value listed in this entry to 15%-20% of the value listed. |
EAS Grant - Application HF6v2PvT1XmW9+VVaN6AiQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Motorola Solutions, Inc. 8000 West Sunrise Blvd Ft Lauderdale, FL 33322 United States |
Date of Grant: 09/13/2004 Application Dated: 09/13/2004 |
| Attention: Deanna Zakharia , Regulatory Compliance Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | AZ489FT4866 |
| Name of Grantee: | Motorola Solutions, Inc. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | HAND HELD PORTABLE 2-WAY R4ADIO |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BE | 80, 90, 90.210 | 450.0 - 520.0 | 6.0 | 2.0 PM | 16K0F3E |
| BE | 80, 90, 90.210 | 450.0 - 450.0 | 6.0 | 2.0 PM | 11K0F3E |
| BE | 80, 90, 90.210 | 450.0 - 520.0 | 6.0 | 2.0 PM | 8K10F1E |
| BE | 80, 90, 90.210 | 450.0 - 520.0 | 6.0 | 2.0 PM | 8K10F1D |
| BE | 80, 90, 90.210 | 450.0 - 520.0 | 6.0 | 2.0 PM | 20K0F1E |
| Power listed is conducted. Output at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the three antennas tested for this filing in Push-to-Talk and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 4.54 mW/kg; Body-worn: 6.41 mW/kg accounting for a 50% duty cycle. |
| BE: | The output power is continuously variable from the value listed in this entry to 15%-20% of the value listed. |
| Mail To: |