FCC ID AZ489FT5818

iDEN i30sx

by Motorola Solutions, Inc.

Grantee Code: AZ4   Product Code: 89FT5818
Latest application date: 2002-03-21

FCC ID Device Details

FCC IDAZ489FT5818
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeAZ4
Product Code89FT5818
Applicant BusinessMotorola Solutions, Inc. 🇺🇸
Related Domains motorolasolutions.com
Equipment ClassiDEN i30sx

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
806-825 MHzOriginal Equipment2002-03-21

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2002-03-21PDF 1.6 MB
Internal PhotosInternal Photos2002-03-21PDF 174.1 KB
External PhotosExternal Photos2002-03-21PDF 86.3 KB
FCC LabelID Label/Location Info2002-03-21PDF 74.1 KB
List of Exhibits IndexID Label/Location Info2002-03-21PDF 12.2 KB
Operational DescriptionOperational Description2002-03-21PDF 20 KB
Resp to corrs 22103Operational Description2002-03-21PDF 12.3 KB
Test Setup ProceduresTest Setup Photos2002-03-21PDF 41.4 KB
Test Report Ex 6aTest Report2002-03-21PDF 663.4 KB
Test Report Ex 6bTest Report2002-03-21PDF 115.4 KB
Test Report Ex 6cTest Report2002-03-21PDF 60.2 KB
Test Report Ex 6dTest Report2002-03-21PDF 276.8 KB
Certification of DataAttestation Statements2002-03-21PDF 7.2 KB
Confidentiality RequestCover Letter(s)2002-03-21PDF 119 KB
Cover LetterCover Letter(s)2002-03-21PDF 13.7 KB
Resp to corres 22299Cover Letter(s)2002-03-21PDF 26 KB
Resp to corrs 22103Cover Letter(s)2002-03-21PDF 14.4 KB
Resp to corrs 22103RF Exposure Info2002-03-21PDF 2.8 MB
SAR ReportRF Exposure Info2002-03-21PDF 1.9 MB
Circuit Descriptions Metadata onlyBlock DiagramPDF 39.2 KB
Schematics Metadata onlySchematicsPDF 190.4 KB
Parts List and Tuneup Info Metadata onlyParts List/Tune Up InfoPDF 52 KB

Application Information

Application IDuN8AL2AYjXI+inmmdLvURA==
Final Action Date2002-03-21
Application PurposeOriginal Equipment
Applicant FRN0003778479
Model89FT5818
Frequency Range806-825 MHz
Equipment ClassTNE - Licensed Non-Broadcast Transmitter Held to Ear
Device DescriptioniDEN i30sx
Responsible PartyDeanna Zakharia, Regulatory Compliance Manager, deanna.zakharia@motorolasolutions.com , 9547234707
Technical ContactMike Ramnath, Motorola Inc, mike.ramnath@motorola.com , 954-723-5793
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsMaximum reported SAR values are (W/kg): Head--1.4, Body-worn--.78, held-to-face--.15.

Applications

Application IDDatePurpose
uN8AL2AYjXI+inmmdLvURA==2002-03-21Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
806-825 MHz0.6711.9ppm18K3D7W9BG
896-901 MHz0.7771.9ppm18K3D7W9BG

Grants

TCB Grant - Application uN8AL2AYjXI+inmmdLvURA==

This application does not exist.

EAS Grant - Application uN8AL2AYjXI+inmmdLvURA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
United States
  Date of Grant: 03/21/2002

Application Dated: 12/19/2001
 
Attention: Deanna Zakharia , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT5818
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Ear
Notes: iDEN i30sx
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BG 90 806.0  -  825.0 0.671 1.9  PM 18K3D7W
BG 90 896.0  -  901.0 0.777 1.9  PM 18K3D7W

Power is ERP using integral antenna.

SAR compliance for body-worn operating configurations is limited to the specific belt-clips/holsters/accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.

Maximum reported SAR values are (W/kg): Head--1.4, Body-worn--.78, held-to-face--.15.


BG: The output power is continuously variable from the value listed in this entry to 25%-30% of the value listed.