FCC ID AZ489FT7019

ic602 CDMA/iDEN Dual Mode

by Motorola Solutions, Inc.

Grantee Code: AZ4   Product Code: 89FT7019
Latest application date: 2007-07-12

FCC ID Device Details

FCC IDAZ489FT7019
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeAZ4
Product Code89FT7019
Applicant BusinessMotorola Solutions, Inc. 🇺🇸
Related Domains motorolasolutions.com
Equipment Classic602 CDMA/iDEN Dual Mode
Test FirmMotorola Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
806-825 MHzClass II permissive change or modification of presently authorized equipment2007-07-12
806-825 MHzClass II permissive change or modification of presently authorized equipment2006-09-18
806-825 MHzOriginal Equipment2006-08-24
806-825 MHzOriginal Equipment2006-07-07
902.525-927.475 MHzOriginal Equipment2006-06-30

Exhibits

DocumentTypeAvailableFile
users manualUsers Manual2007-07-12PDF 2.4 MB
USERS MANUAL 1Users Manual2006-09-18PDF 2.7 MB
USERS MANUAL 2Users Manual2006-09-18PDF 45.3 KB
USERS MANUALUsers Manual2006-07-07PDF 2.7 MB
INTERNAL PHOTOSInternal Photos2006-08-21PDF 192.7 KB
EXTERNAL PHOTOSExternal Photos2006-08-21PDF 249.7 KB
hac stickerID Label/Location Info2007-07-12PDF 674.9 KB
LABELID Label/Location Info2006-07-07PDF 16.8 KB
LABEL LOCATIONID Label/Location Info2006-07-07PDF 43.5 KB
LABEL LOCATIONTest Report2006-06-30PDF 43.5 KB
TEST SETUP PHOTOSTest Setup Photos2006-06-30PDF 251.4 KB
hac test report for tcoilTest Report2007-07-12PDF 1.6 MB
HAC REPORTTest Report2006-09-18PDF 1.7 MB
FREQUENCY STABILTYTest Report2006-07-07PDF 21 KB
MEASUREMENT PROCEDURESTest Report2006-07-07PDF 160.5 KB
TEST REPORTTest Report2006-07-07PDF 1.1 MB
part 90 line spurious voltageTest Report2006-07-07PDF 143.8 KB
part 90 transmitter dataTest Report2006-07-07PDF 167.7 KB
MT DATATest Report2006-06-30PDF 127.6 KB
MT LINE SPURIOUSTest Report2006-06-30PDF 100.5 KB
MT RADIATED EMISSIONSTest Report2006-06-30PDF 113.7 KB
LINE SPURIOUS VOLTAGE Metadata onlyTest ReportPDF 143.8 KB
MEASURED DATA Metadata onlyTest ReportPDF 167.7 KB
cover letterCover Letter(s)2007-07-12PDF 119.5 KB
COVER LETTERCover Letter(s)2006-09-18PDF 30.7 KB
CUSTOMER RESPONSE LETTERCover Letter(s)2006-09-18PDF 81.9 KB
CONFIDENTIALITY LETTERCover Letter(s)2006-07-07PDF 31.8 KB
CORRESPONDENCE SUMMARYCover Letter(s)2006-07-07PDF 69.2 KB
COVER LETTERCover Letter(s)2006-07-07PDF 37.9 KB
CORRESPONDANCE SUMMARYCover Letter(s)2006-06-30PDF 69.2 KB
CORRESPONDENCE SUMMARYCover Letter(s)PDF 69.2 KB
response to RT 30889 Applicant request for dismissalCover Letter(s)PDF 30.5 KB
RF EXPOSURE 1RF Exposure Info2006-07-07PDF 3.5 MB
RF EXPOSURE 2RF Exposure Info2006-07-07PDF 977.5 KB
BLOCK DIAGRAM Metadata onlyBlock DiagramPDF 48.3 KB
SCHEMATICS Metadata onlySchematicsPDF 72 KB
OPERATIONAL DESCRIPTION Metadata onlyOperational DescriptionPDF 343.3 KB
PARTS LIST Metadata onlyParts List/Tune Up InfoPDF 28.2 KB

Application Information

Application IDLT9FsGel+PjmVJ21yM2w/g==
Final Action Date2007-07-12
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0003778479
Model89FT7019
Frequency Range806-825 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device Descriptionic602 CDMA/iDEN Dual Mode
Responsible PartyKim Uong, Regulatory Compliance Engineer, EKU001@motorolasolutions.com , 9547235422
Test FirmAlbert Patapack, Motorola Inc., albert.patapack@motorola.com , 847-523-3670
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is EIRP for part 24 and conducted for part 90. SAR compliance for body-worn operations is restricted to belt-clips, holsters, and accessories supplied or designated for this product and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 2.5 cm separation between the device, including its antenna, whether extended or retracted, and the users body. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. SAR for Part 90 was evaluated for held-to-ear and held-to-face operating modes. The highest reported SAR values are: Part 24: Body: 1.24 W/kg, Head: 1.17 W/kg; Part 90: Body: 0.14 W/kg, Head: 0.37 W/kg. Power output for the band 806-825 MHz is continuously variable from the value listed to 0.88 mW. HAC ratings: M4 T4

Applications

Application IDDatePurpose
LT9FsGel+PjmVJ21yM2w/g==2007-07-12Class II permissive change or modification of presently authorized equipment
IHOgsttPItugT0fTWQCqiA==2006-09-18Class II permissive change or modification of presently authorized equipment
lu7sC8uxklPq59C2plxqhw==2006-08-24Original Equipment
NkWDeDGGSRs2g746oGEr/Q==2006-07-07Original Equipment
Ox8/1l5o+CXYXqO3PhpsTw==2006-06-30Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
806-825 MHz0.641.9ppm18K3D7W9HC
806-825 MHz0.64000001.9000000000ppm18K3D7W90
806-825 MHz0.641.9ppm18K3D7W9
902.525-927.475 MHz0.891000015C
1851.25-1908.75 MHz0.6282ppm1M25F9W24E
1851.25-1908.75 MHz0.6282ppm1M25F9W24EHC

Grants

TCB Grant - Application Ox8/1l5o+CXYXqO3PhpsTw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 06/30/2006

Application Dated: 06/30/2006
Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
 
Attention: Deanna Zakharia , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT7019
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: Digital Transmission System
Notes: iDEN ic502 WITH CDMA 2000
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.525  -  927.475 0.891  

Power listed is conducted. SAR compliance for body-worn operations is restricted to belt-clips, holsters, and accessories supplied or designated for this product and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 2.5 cm separation between the device, including its antenna, whether extended or retracted, and the users body. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. SAR was evaluated for held-to-face and body-worn operating modes. The highest reported SAR values are: Body: 1.14 W/kg, Head: 1.24 W/kg

EAS Grant - Application Ox8/1l5o+CXYXqO3PhpsTw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
United States
  Date of Grant: 06/30/2006

Application Dated: 06/30/2006
 
Attention: Deanna Zakharia , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT7019
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: Digital Transmission System
Notes: iDEN ic502 WITH CDMA 2000
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.525  -  927.475 0.891  

Power listed is conducted. SAR compliance for body-worn operations is restricted to belt-clips, holsters, and accessories supplied or designated for this product and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 2.5 cm separation between the device, including its antenna, whether extended or retracted, and the users body. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. SAR was evaluated for held-to-face and body-worn operating modes. The highest reported SAR values are: Body: 1.14 W/kg, Head: 1.24 W/kg



TCB Grant - Application NkWDeDGGSRs2g746oGEr/Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 07/07/2006

Application Dated: 06/30/2006
Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
 
Attention: Deanna Zakharia , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT7019
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: iDEN ic502 WITH CDMA 2000
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1851.25  -  1908.75 0.628 2.0  PM 1M25F9W
90 806.0  -  825.0 0.64 1.9  PM 18K3D7W

Power listed is EIRP for part 24 and conducted for part 90. SAR compliance for body-worn operations is restricted to belt-clips, holsters, and accessories supplied or designated for this product and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 2.5 cm separation between the device, including its antenna, whether extended or retracted, and the users body. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. SAR for Part 90 was evaluated for held-to-ear and held-to-face operating modes. The highest reported SAR values are: Part 24: Body: 1.24 W/kg, Head: 1.17 W/kg; Part 90: Body: 0.14 W/kg, Head: 0.37 W/kg.

Power output for the band 806-825 MHz is continuously variable from the value listed to 0.88 mW.


EAS Grant - Application NkWDeDGGSRs2g746oGEr/Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
United States
  Date of Grant: 07/07/2006

Application Dated: 06/30/2006
 
Attention: Deanna Zakharia , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT7019
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: iDEN ic502 WITH CDMA 2000
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1851.25  -  1908.75 0.628 2.0  PM 1M25F9W
90 806.0  -  825.0 0.64 1.9  PM 18K3D7W

Power listed is EIRP for part 24 and conducted for part 90. SAR compliance for body-worn operations is restricted to belt-clips, holsters, and accessories supplied or designated for this product and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 2.5 cm separation between the device, including its antenna, whether extended or retracted, and the users body. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. SAR for Part 90 was evaluated for held-to-ear and held-to-face operating modes. The highest reported SAR values are: Part 24: Body: 1.24 W/kg, Head: 1.17 W/kg; Part 90: Body: 0.14 W/kg, Head: 0.37 W/kg.

Power output for the band 806-825 MHz is continuously variable from the value listed to 0.88 mW.



TCB Grant - Application lu7sC8uxklPq59C2plxqhw==

This application does not exist.

EAS Grant - Application lu7sC8uxklPq59C2plxqhw==

This application currently is not in final status.

TCB Grant - Application LT9FsGel+PjmVJ21yM2w/g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 07/12/2007

Application Dated: 07/11/2007
Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
 
Attention: Kim Uong , Regulatory Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT7019
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: ic602 CDMA/iDEN Dual Mode
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
HC 24E 1851.25  -  1908.75 0.628 2.0  PM 1M25F9W
HC 90 806.0  -  825.0 0.64 1.9  PM 18K3D7W

Power listed is EIRP for part 24 and conducted for part 90. SAR compliance for body-worn operations is restricted to belt-clips, holsters, and accessories supplied or designated for this product and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 2.5 cm separation between the device, including its antenna, whether extended or retracted, and the users body. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. SAR for Part 90 was evaluated for held-to-ear and held-to-face operating modes. The highest reported SAR values are: Part 24: Body: 1.24 W/kg, Head: 1.17 W/kg; Part 90: Body: 0.14 W/kg, Head: 0.37 W/kg.

Power output for the band 806-825 MHz is continuously variable from the value listed to 0.88 mW.

HAC ratings: M4 T4


HC: This equipment complies with the hearing aid compatibility technical requirements of Section 20.19 of the rules.

EAS Grant - Application LT9FsGel+PjmVJ21yM2w/g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
United States
  Date of Grant: 07/12/2007

Application Dated: 07/11/2007
 
Attention: Kim Uong , Regulatory Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT7019
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: ic602 CDMA/iDEN Dual Mode
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
HC 24E 1851.25  -  1908.75 0.628 2.0  PM 1M25F9W
HC 90 806.0  -  825.0 0.64 1.9  PM 18K3D7W

Power listed is EIRP for part 24 and conducted for part 90. SAR compliance for body-worn operations is restricted to belt-clips, holsters, and accessories supplied or designated for this product and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 2.5 cm separation between the device, including its antenna, whether extended or retracted, and the users body. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. SAR for Part 90 was evaluated for held-to-ear and held-to-face operating modes. The highest reported SAR values are: Part 24: Body: 1.24 W/kg, Head: 1.17 W/kg; Part 90: Body: 0.14 W/kg, Head: 0.37 W/kg.

Power output for the band 806-825 MHz is continuously variable from the value listed to 0.88 mW.

HAC ratings: M4 T4


HC: This equipment complies with the hearing aid compatibility technical requirements of Section 20.19 of the rules.

Mail To:


EA421936

TCB Grant - Application IHOgsttPItugT0fTWQCqiA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 09/18/2006

Application Dated: 09/18/2006
Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
 
Attention: Deanna Zakharia , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT7019
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: iDEN ic502 WITH CDMA 2000
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
HC 90 806.0  -  825.0 0.64 1.9  PM 18K3D7W
HC 24E 1851.25  -  1908.75 0.628 2.0  PM 1M25F9W

Power listed is EIRP for part 24 and conducted for part 90. SAR compliance for body-worn operations is restricted to belt-clips, holsters, and accessories supplied or designated for this product and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 2.5 cm separation between the device, including its antenna, whether extended or retracted, and the users body. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. SAR for Part 90 was evaluated for held-to-ear and held-to-face operating modes. The highest reported SAR values are: Part 24: Body: 1.24 W/kg, Head: 1.17 W/kg; Part 90: Body: 0.14 W/kg, Head: 0.37 W/kg.

Power output for the band 806-825 MHz is continuously variable from the value listed to 0.88 mW.

HAC rating: M4


HC: This equipment complies with the hearing aid compatibility technical requirements of Section 20.19 of the rules.

EAS Grant - Application IHOgsttPItugT0fTWQCqiA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Motorola Solutions, Inc.
8000 West Sunrise Blvd
Ft Lauderdale, FL 33322
United States
  Date of Grant: 09/18/2006

Application Dated: 09/18/2006
 
Attention: Deanna Zakharia , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AZ489FT7019
Name of Grantee:  Motorola Solutions, Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: iDEN ic502 WITH CDMA 2000
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
HC 90 806.0  -  825.0 0.64 1.9  PM 18K3D7W
HC 24E 1851.25  -  1908.75 0.628 2.0  PM 1M25F9W

Power listed is EIRP for part 24 and conducted for part 90. SAR compliance for body-worn operations is restricted to belt-clips, holsters, and accessories supplied or designated for this product and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 2.5 cm separation between the device, including its antenna, whether extended or retracted, and the users body. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. SAR for Part 90 was evaluated for held-to-ear and held-to-face operating modes. The highest reported SAR values are: Part 24: Body: 1.24 W/kg, Head: 1.17 W/kg; Part 90: Body: 0.14 W/kg, Head: 0.37 W/kg.

Power output for the band 806-825 MHz is continuously variable from the value listed to 0.88 mW.

HAC rating: M4


HC: This equipment complies with the hearing aid compatibility technical requirements of Section 20.19 of the rules.

Mail To: