GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden

Nihon Kohden SDIO Wireless Module

Page 1 of GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden
Page 2 of GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden
Page 3 of GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden
Page 4 of GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden
Page 5 of GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden
Page 6 of GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden
Page 7 of GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden
Page 8 of GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden
Page 9 of GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden
Page 10 of GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden

Test report No.
Page
Issued date
FCC ID
: 12551127S
: 1 of 11
: December 14, 2018
: B6BGZ-1XXP
RADIO TEST REPORT
Test Report No. : 12551127S
Applicant
NIHON KOHDEN CORPORATION
Type of Equipment
SDIO Wireless Module
Model No.
SX-SDMAN
FCC ID
B6BGZ-1XXP
Test regulation
FCC Part 15 Subpart E: 2018
For Permissive Change
Test item
Maximum Conducted Output Power
* U-NII-2C only
Test Result
1.
2.
3.
4.
5.
6.
7.
8.
9.
Complied
This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
The results in this report apply only to the sample tested.
This sample tested is in compliance with the limits of the above regulation.
The test results in this test report are traceable to the national or international standards.
This test report must not be used by the customer to claim product certification, approval, or endorsement by any
agency of the Federal Government.
This test report covers Radio technical requirements.
It does not cover administrative issues such as Manual or non-Radio test related Requirements. (if applicable)
The all test items in this test report are conducted by UL Japan, Inc. Shonan EMC Lab.
The opinions and the interpretations to the result of the description in this report are outside scopes where
UL Japan has been accredited.
The module has been certified. (FCC ID: N6C-SDMAN, Test report for FCC part 15 subpart E: 12548845H-A-R1)
Date of test:
November 8, 2018
Representative test engineer:
Yosuke Ishikawa
Engineer
Consumer Technology Division
Approved by:
Toyokazu Imamura
Leader
Consumer Technology Division
The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
RTL02610
There is no testing item of "Non-accreditation".
UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone : +81 463 50 6400
Facsimile : +81 463 50 6401
13-EM-F0429
Test report No.
Page
Issued date
FCC ID
REVISION HISTORY
Original Test Report No.: 12551127S
Revision
- (Original)
Test report No.
12551127S
Date
December 14, 2018
Page revised
UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone : +81 463 50 6400
Facsimile : +81 463 50 6401
Contents
: 12551127S
: 2 of 11
: December 14, 2018
: B6BGZ-1XXP
Test report No.
Page
Issued date
FCC ID
CONTENTS
: 12551127S
: 3 of 11
: December 14, 2018
: B6BGZ-1XXP
PAGE
SECTION 1: Customer information.......................................................................................................4
SECTION 2: Equipment under test (E.U.T.) .........................................................................................4
SECTION 3: Test results .........................................................................................................................5
SECTION 4: Operation of E.U.T. during testing ..................................................................................6
SECTION 5: Antenna Terminal Conducted Tests ................................................................................7
APPENDIX 1: Test data ..........................................................................................................................8
Maximum Conducted Output Power ..................................................................................................8
APPENDIX 2: Test instruments ...........................................................................................................10
APPENDIX 3: Photographs of test setup .............................................................................................11
Antenna Terminal testing .................................................................................................................. 11
UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone : +81 463 50 6400
Facsimile : +81 463 50 6401
Test report No.
Page
Issued date
FCC ID
SECTION 1:
Customer information
Company Name
Address
Telephone Number
Facsimile Number
Contact Person
SECTION 2:
2.1
NIHON KOHDEN CORPORATION
1-31-4, Nishiochiai, Shinjuku-ku, Tokyo, 161-8560, Japan
+81-3-5996-8354
+81-3-5996-8374
Soichi Maeno
Equipment under test (E.U.T.)
Identification of E.U.T.
Type of Equipment
Model No.
Serial No.
Rating
Receipt Date of Sample
Country of Mass-production
Condition of EUT
Modification of EUT
2.2
: 12551127S
: 4 of 11
: December 14, 2018
: B6BGZ-1XXP
SDIO Wireless Module
SX-SDMAN
Refer to Section 4, Clause 4.2
DC 3.3 V
November 5, 2018
Japan
Production model
No Modification by the test lab.
Product Description
Model: SX-SDMAN (referred to as the EUT in this report) is a SDIO Wireless Module.
General specification
Clock frequency(ies) in the system
26 MHz
Radio specification
Radio Type
Method of Frequency Generation
Power Supply (inner)
Transceiver
Synthesizer
DC1.2V
Specification of Wireless LAN (IEEE 802.11b/g/a/n-20)
Type of radio
IEEE802.11b
IEEE802.11g
Frequency
2412 MHz
2412 MHz - 2462 MHz
of operation
- 2462 MHz
Type of
modulation
Channel spacing
Antenna type
Antenna Gain
Antenna
Connector type
DSSS
(CCK, DQPSK,
DBPSK)
5 MHz
OFDM-CCK
(64QAM, 16QAM,
QPSK, BPSK)
IEEE802.11a
5180 MHz - 5320 MHz
5500 MHz - 5700 MHz
5745 MHz - 5825 MHz
OFDM
(64QAM, 16QAM, QPSK, BPSK)
20 MHz
Mini-Nanoblade antenna: Laird Technologies
Stand Alone antenna: Molex
Mini-Nanoblade antenna: 2.5 dBi (2.4 GHz), 4.8 dBi (5 GHz)
Stand Alone antenna: 3.0 dBi (2.4 GHz), 4.6 dBi (5 GHz)
U.FL connector
UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone : +81 463 50 6400
Facsimile : +81 463 50 6401
IEEE802.11n (20 M band)
2412 MHz - 2462 MHz
5180 MHz - 5320 MHz
5500 MHz - 5700 MHz
5745 MHz - 5825 MHz
2.4 GHz band: 5 MHz
5 GHz band: 20 MHz
Test report No.
Page
Issued date
FCC ID
: 12551127S
: 5 of 11
: December 14, 2018
: B6BGZ-1XXP
SECTION 3: Test results
3.1
Test result
KDB 447498D01 (v06) has the following exclusion for portable devices:
This device f = 5.7 GHz, distance = 5mm (minimum separation distance: 5 mm was used in the calculation)
and the measured maximum average output power was 1 mW
So for this device:
1 mW [measured maximum average output power] / 5 mm [minimum separation distance] * ( √ 5.7) = 0.5
This is less than 3.0, so no SAR is required.
Note: UL Japan’s Work Procedures No. 13-EM-W0422.
3.2
Uncertainty
The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k=2.
Uncertainty (+/-)
Antenna terminal test
Power Measurement above 1 GHz (Average Detector)_SPM-06
0.48 dB
Power Measurement above 1 GHz (Peak Detector)_SPM-06
0.66 dB
Power Measurement above 1 GHz (Average Detector)_SPM-07
0.47 dB
Power Measurement above 1 GHz (Peak Detector)_SPM-07
0.64 dB
Power Measurement above 1 GHz (Average Detector)_SPM-13
0.90 dB
Power Measurement above 1 GHz (Peak Detector)_SPM-13
1.04 dB
3.3
Test Location
UL Japan, Inc. Shonan EM C Lab.
1-22-3, M egumigaoka, Hiratsuka-shi, Kanagawa-ken 259-1220 JAPAN
Telephone: +81 463 50 6400, Facsimile: +81 463 50 6401
JAB Accreditation No. RTL02610
FCC Test Firm Registration Number: 839876
Test site
No.1 Semi-anechoic
chamber
No.2 Semi-anechoic
chamber
No.3 Semi-anechoic
chamber
No.4 Semi-anechoic
chamber
No.1 Shielded room
No.2 Shielded room
No.3 Shielded room
No.4 Shielded room
No.5 Shielded room
No.6 Shielded room
No.8 shielded room
No.1 M easurement
room
3.4
IC Registration
Number
Width x Depth x
Height (m)
Size of reference ground plane (m) /
horizontal conducting plane
M aximum
measurement
distance
2973D-1
20.6 x 11.3 x 7.65
20.6 x 11.3
10 m
2973D-2
20.6 x 11.3 x 7.65
20.6 x 11.3
10 m
2973D-3
12.7 x 7.7 x 5.35
12.7 x 7.7
5m
8.1 x 5.1 x 3.55
8.1 x 5.1
6.8 x 4.1 x 2.7
6.8 x 4.1 x 2.7
6.3 x 4.7 x 2.7
4.4 x 4.7 x 2.7
7.8 x 6.4 x 2.7
7.8 x 6.4 x 2.7
3.45 x 5.5 x 2.4
6.8 x 4.1
6.8 x 4.1
6.3 x 4.7
4.4 x 4.7
7.8 x 6.4
7.8 x 6.4
3.45 x 5.5
2.55 x 4.1 x 2.5
Test data, Test instruments, and Test set up
Refer to APPENDIX.
UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone : +81 463 50 6400
Facsimile : +81 463 50 6401
Test report No.
Page
Issued date
FCC ID
SECTION 4:
4.1
: 12551127S
: 6 of 11
: December 14, 2018
: B6BGZ-1XXP
Operation of E.U.T. during testing
Operating Mode(s)
Mode
Tested frequency
Worst data
mode *1)
6 Mbps
MCS 0
Tested antenna
port *2)
Transmitting IEEE 802.11a
5500 MHz, 5580 MHz, 5700 MHz
5500 MHz, 5580 MHz, 5700 MHz
Transmitting IEEE 802.11n-20HT
Test condition: Worst
The EUT transmits vital signs to 4 monitors. The lowest rate was selected since ON time of transmitting is
longest.
Power setting:
IEEE 802.11a: 14.0 dBm, IEEE 802.11n-20HT: 14.0 dBm
*1) Software (Firmware): ver.02-10A (Worst data mode based on ver.02-10)
*2) After the comparison between Antenna port 1 and Antenna port 2, test was performed with the antenna that
had higher power as a representative. (See the report of 10393347S-D)
4.2
Configuration and peripherals
100 V/ 50 Hz
100 V/ 50 Hz
100 V/ 50 Hz
100 V/ 50 Hz
100 V/ 50 Hz
100 V/ 50 Hz
100 V/ 50 Hz
100 V/ 50 Hz
UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone : +81 463 50 6400
Facsimile : +81 463 50 6401
Test report No.
Page
Issued date
FCC ID
Description of EUT and Support equipment
No.
Item
Model number
SDIO Wireless
SX-SDMAN
Module
Vital sign telemeter
GZ-130P OPNo.30A
Shield tent
Wireless LAN access
AIR-CAP3702E-A-K9
point
AC adaptor
AA25480L
Power injector
AIR-PWRINJ5
HUB
CO-BSW16TX
LCD display unit
AC adaptor
Central monitor
Central monitor
Central monitor
Central monitor
VL-611R
HEMP100G-S120650
-7L
CNS-6201
CNS-6201
CNS-6201
CNS-6201
List of cables used
Name
No.
10
11
12
13
14
15
16
17
DC
AC
AC
AC
DC
AC
DVI
AC
AC
AC
AC
LAN
LAN
LAN
LAN
LAN
LAN
Serial number
84253F 269BA8
Manufacturer
silex technology, Inc.
Remarks
EUT
01204
FTX18227609
Nihon Kohden
Sondecx
Cisco Systems
ALD02510FEW
DCA171317VV
12129601403007
22 Rev.A3
00617
3316007801F0H-1246-002E
01871
00590
00589
01121
Cisco Systems
Cisco Systems
Corega
Nihon Kohden
HiTRON
Nihon Kohden
Nihon Kohden
Nihon Kohden
Nihon Kohden
Length (m)
1.8
0.8
1.5
1.5
1.0
2.0
1.5
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
Shield
Cable
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Shielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
SECTION 5: Antenna Terminal Conducted Tests
Test Procedure
The tests were made with below setting connected to the antenna port.
Test data
Test result
: 12551127S
: 7 of 11
: December 14, 2018
: B6BGZ-1XXP
: APPENDIX
: Pass
UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone : +81 463 50 6400
Facsimile : +81 463 50 6401
Connector
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Shielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Unshielded
Remarks
Test report No.
Page
Issued date
FCC ID
APPENDIX 1: Test data
Maximum Conducted Output Power
Report No.
Test place
Date
Temperature / Humidity
Engineer
Mode
12551127S
Shonan EMC Lab. No.6 Shielded Room
November 8, 2018
28 deg. C / 37 % RH
Yosuke Ishikawa
Tx
6 M bps antenna port: 2
(Time averaging power)
11a
e.i.r.p.
Tested
Power Cable Atten. Antenna Conducted Power
Result
Result
Frequency M eter
Loss
Loss
Gain
Reading
[M Hz]
[dBm]
[dB]
[dB]
[dBi]
[dBm]
[mW]
[dBm]
[mW]
5500 -16.31
5.07
9.59
4.80
-1.65
0.68
3.15
2.07
5580 -16.40
5.09
9.62
4.80
-1.69
0.68
3.11
2.05
5700 -16.20
4.94
9.67
4.80
-1.59
0.69
3.21
2.09
Sample Calculation:
Conducted Power Result = Reading + Cable Loss (including the Directional Coupler) + Atten. Loss
e.i.r.p. Result = Conducted Power Result + Antenna Gain
M CS0 antenna port: 2
(Time averaging power)
11n-20
e.i.r.p.
Tested
Power Cable Atten. Antenna Conducted Power
Result
Result
Frequency M eter
Loss
Loss
Gain
Reading
[M Hz]
[dBm]
[dB]
[dB]
[dBi]
[dBm]
[mW]
[dBm]
[mW]
5500 -15.47
5.07
9.59
4.80
-0.81
0.83
3.99
2.51
5580 -15.26
5.09
9.62
4.80
-0.55
0.88
4.25
2.66
5700 -14.85
4.94
9.67
4.80
-0.24
0.95
4.56
2.86
Sample Calculation:
Conducted Power Result = Reading + Cable Loss (including the Directional Coupler) + Atten. Loss
e.i.r.p. Result = Conducted Power Result + Antenna Gain
UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone : +81 463 50 6400
Facsimile : +81 463 50 6401
: 12551127S
: 8 of 11
: December 14, 2018
: B6BGZ-1XXP
Test report No.
Page
Issued date
FCC ID
: 12551127S
: 9 of 11
: December 14, 2018
: B6BGZ-1XXP
Duty Cycle
Report No.
Test place
Date
Temperature / Humidity
Engineer
Mode
12551127S
Shonan EMC Lab. No.6 Shielded Room
November 8, 2018
28 deg. C / 37 % RH
Yosuke Ishikawa
Tx
Tx 11a 6Mbps with antenna port 2
1 cycle = 256.8 ms
On Time = 6.932 ms
Tx 11n-20 MCS0 with antenna port 2
1 cycle = 255.3 ms
On Time = 6.488 ms
UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone : +81 463 50 6400
Facsimile : +81 463 50 6401
Test report No.
Page
Issued date
FCC ID
: 12551127S
: 10 of 11
: December 14, 2018
: B6BGZ-1XXP
APPENDIX 2: Test instruments
Test Instruments
Test Item
LIMS ID
Description
Manufacturer
Model
AT
145089
AGILENT
E4446A
AT
146319
A&D
AD-5681
AT
AT
AT
AT
146310
145166
145175
145042
Spectrum
Analyzer
Humidity
Indicator
Power sensor
Coaxial Cable
Coaxial Cable
Coaxial Cable
AGILENT
Suhner
Suhner
Junkosha
AT
145183
Coaxial Cable
Junkosha
AT
144995
RS Pro
AT
144996
AT
AT
AT
171616
145132
167151
Microwave
cable
Microwave
cable
Terminator
Attenuator
Step Attenuator
AT
167152
Step Attenuator KEYSIGHT
AT
145439
Mini-Circuits
AT
146247
Directional
Coupler
Power Meter
N1923A
MY5326009
SUCOFLEX 102 31599/2
SUCOFLEX 102 31600/2
MWX241-01000K OCT-08-13MSKMS
046
MWX241-02000K OCT-09-13MSKMS
005
R-132G7210
100CO
R-132G7210
100CO
M1459A
89025
54A-10
W5692
8494B
MY4215763
8496B
MY4215119
ZGDC35-93HP+ 210
AGILENT
8990B
RS Pro
WEINSCHEL
Weinschel Corp.
KEYSIGHT
Serial
Last
Calibration Cal Int
Calibration Due Date
Date
MY4618052 2018/10/7 2019/10/31 12
4064561
2018/10/25 2019/10/31 12
2018/7/13
2018/3/19
2018/3/19
2018/4/20
2019/7/31
2019/3/31
2019/3/31
2019/4/30
12
12
12
12
2017/11/22 2018/11/30 12
2018/4/4
2019/4/30
12
2018/4/4
2019/4/30
12
2018/7/10 2019/7/31 12
2017/11/22 2018/11/30 12
2018/2/7
2019/2/28 12
2018/2/7
2019/2/28
12
2018/7/30
2019/7/31
12
MY5100272 2018/7/13
2019/7/31
12
*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int (month) are instruments that
Calibration is not required (e.g. software), or instruments checked in advance before use.
The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.
As for some calibrations performed after the tested dates, those test equipment have been controlled by means
of an unbroken chains of calibrations.
Test item:
AT: Antenna Terminal Conducted test
UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone : +81 463 50 6400
Facsimile : +81 463 50 6401
Download: GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden
Mirror Download [FCC.gov]GZ-1XXP SDIO Wireless Module Test Report 03 FCC _NII_12551127S Nihon Kohden
Document ID4181814
Application IDUQ/r/dINRqL1MIA07BXTaA==
Document Description03 FCC Test Report_NII_12551127S
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize34.65kB (433146 bits)
Date Submitted2019-02-26 00:00:00
Date Available2019-02-27 00:00:00
Creation Date2018-12-14 14:42:50
Producing SoftwareAcrobat Distiller 15.0 (Windows)
Document Lastmod2019-01-25 13:17:50
Document Title03 FCC Test Report_NII_12551127S
Document CreatorPScript5.dll Version 5.2.2

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : 
Create Date                     : 2018:12:14 14:42:50+09:00
Modify Date                     : 2019:01:25 13:17:50+09:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2019:01:25 13:17:50+09:00
Producer                        : Acrobat Distiller 15.0 (Windows)
Format                          : application/pdf
Creator                         : 
Title                           : 
Document ID                     : uuid:1d73703c-5f6f-427c-b121-8fa1498579a5
Instance ID                     : uuid:54a357d7-99b9-4e1b-aea0-b16e0e58db4b
Page Count                      : 10