A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.

Apple Inc. Tablet Device

Page 1 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 2 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 3 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 4 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 5 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 6 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 7 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 8 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 9 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 10 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 11 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 12 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 13 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 14 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 15 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 16 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 17 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 18 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 19 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 20 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 21 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 22 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 23 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Page 24 of A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.

Test Laboratory: UL Verification Services Inc. SAR Lab C
Date/Time: 8/4/2015 11:43:15 AM
20150804_SystemPerformanceCheck-D5GHzV2 SN 1003
Frequency: 5800 MHz; Duty Cycle: 1:1;
Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 5800 MHz; σ = 6.137 S/m; εr = 46.994; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Probe: EX3DV4 - SN3885; ConvF(4.13, 4.13, 4.13); Calibrated: 9/15/2014;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1117
Body/5.8 GHz, Pin=100mW/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 20.3 W/kg
Body/5.8 GHz, Pin=100mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm
Reference Value = 51.116 V/m; Power Drift = -0.15 dB
Peak SAR (extrapolated) = 35.7 W/kg
SAR(1 g) = 7.74 W/kg; SAR(10 g) = 2.15 W/kg
Maximum value of SAR (measured) = 19.0 W/kg
0 dB = 19.0 W/kg = 12.79 dBW/kg
Plot No. 1
Test Laboratory: UL Verification Services Inc. SAR Lab C
Date/Time: 8/4/2015 12:09:00 PM
20150804_SystemPerformanceCheck-D5GHzV2 SN 1003
Frequency: 5800 MHz; Duty Cycle: 1:1
Body/5.8 GHz, Pin=100mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 13.8 W/kg
Plot No. 2
Test Laboratory: UL Verification Services Inc. SAR Lab E
Date/Time: 7/27/2015 8:59:29 AM
20150727_SystemPerformanceCheck-D750V3 SN 1019
Frequency: 750 MHz; Duty Cycle: 1:1;
Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 750 MHz; σ = 0.97 S/m; εr = 53.323; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1257; Calibrated: 9/29/2014
- Probe: EX3DV4 - SN3772; ConvF(8.82, 8.82, 8.82); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1180
Body/Pin=100 mW 2/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.09 W/kg
Body/Pin=100 mW 2/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 33.838 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 1.34 W/kg
SAR(1 g) = 0.906 W/kg; SAR(10 g) = 0.602 W/kg
Maximum value of SAR (measured) = 1.10 W/kg
0 dB = 1.10 W/kg = 0.41 dBW/kg
Plot No. 3
Test Laboratory: UL Verification Services Inc. SAR Lab E
Date/Time: 7/27/2015 9:19:31 AM
20150727_SystemPerformanceCheck-D750V3 SN 1019
Frequency: 750 MHz; Duty Cycle: 1:1
Body/Pin=100 mW 2/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 1.09 W/kg
Plot No. 4
Test Laboratory: UL Verification Services Inc. SAR Lab E
Date/Time: 7/28/2015 11:35:39 AM
20150728_SystemPerformanceCheck-D2600V2 SN 1006
Frequency: 2600 MHz; Duty Cycle: 1:1;
Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 2600 MHz; σ = 2.121 S/m; εr = 51.153; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1257; Calibrated: 9/29/2014
- Probe: EX3DV4 - SN3772; ConvF(6.35, 6.35, 6.35); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 A; Type: QDOVA002AA; Serial: 1258
Body/Pin=100 mW 2/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 5.76 W/kg
Body/Pin=100 mW 2/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 61.035 V/m; Power Drift = -0.06 dB
Peak SAR (extrapolated) = 11.9 W/kg
SAR(1 g) = 5.46 W/kg; SAR(10 g) = 2.41 W/kg
Maximum value of SAR (measured) = 7.93 W/kg
0 dB = 7.93 W/kg = 8.99 dBW/kg
Plot No. 5
Test Laboratory: UL Verification Services Inc. SAR Lab E
Date/Time: 7/28/2015 11:56:14 AM
20150728_SystemPerformanceCheck-D2600V2 SN 1006
Frequency: 2600 MHz; Duty Cycle: 1:1
Body/Pin=100 mW 2/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 7.81 W/kg
Plot No. 6
Test Laboratory: UL Verification Services Inc. SAR Lab E
Date/Time: 8/3/2015 10:30:04 AM
20150803_SystemPerformanceCheck-D2450V2 SN 899
Frequency: 2450 MHz; Duty Cycle: 1:1;
Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 2450 MHz; σ = 1.918 S/m; εr = 54.212; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1257; Calibrated: 9/29/2014
- Probe: EX3DV4 - SN3772; ConvF(6.58, 6.58, 6.58); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 A; Type: QDOVA002AA; Serial: 1258
Body/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 5.30 W/kg
Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 62.740 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 10.9 W/kg
SAR(1 g) = 5.29 W/kg; SAR(10 g) = 2.46 W/kg
Maximum value of SAR (measured) = 7.51 W/kg
0 dB = 7.51 W/kg = 8.76 dBW/kg
Plot No. 7
Test Laboratory: UL Verification Services Inc. SAR Lab E
Date/Time: 8/3/2015 10:50:40 AM
20150803_SystemPerformanceCheck-D2450V2 SN 899
Frequency: 2450 MHz; Duty Cycle: 1:1
Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 7.50 W/kg
Plot No. 8
Test Laboratory: UL Verification Services Inc. SAR Lab F
Date/Time: 7/23/2015 8:55:57 AM
20150723_SystemPerformanceCheck-D835V2 SN 4d002
Frequency: 835 MHz; Duty Cycle: 1:1;
Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 835 MHz; σ = 1.013 S/m; εr = 53.589; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1359; Calibrated: 2/18/2015
- Probe: EX3DV4 - SN3929; ConvF(8.57, 8.57, 8.57); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 (B); Type: QDOVA001BB; Serial: 1118
Body/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.16 W/kg
Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 34.715 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 1.41 W/kg
SAR(1 g) = 0.970 W/kg; SAR(10 g) = 0.641 W/kg
Maximum value of SAR (measured) = 1.17 W/kg
0 dB = 1.17 W/kg = 0.68 dBW/kg
Plot No. 9
Test Laboratory: UL Verification Services Inc. SAR Lab F
Date/Time: 7/23/2015 9:16:25 AM
20150723_SystemPerformanceCheck-D835V2 SN 4d002
Frequency: 835 MHz; Duty Cycle: 1:1
Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 1.17 W/kg
Plot No. 10
Test Laboratory: UL Verification Services Inc. SAR Lab F
Date/Time: 8/6/2015 8:33:54 AM
20150806_SystemPerformanceCheck-D5GHzV2 SN 1168
Frequency: 5200 MHz; Duty Cycle: 1:1;
Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 5200 MHz; σ = 5.318 S/m; εr = 49.266; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1359; Calibrated: 2/18/2015
- Probe: EX3DV4 - SN3929; ConvF(4.41, 4.41, 4.41); Calibrated: 4/22/2015;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1117
Body/5.2 GHz, Pin=100mW/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 19.4 W/kg
Body/5.2 GHz, Pin=100mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm
Reference Value = 53.425 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 34.0 W/kg
SAR(1 g) = 7.97 W/kg; SAR(10 g) = 2.27 W/kg
Maximum value of SAR (measured) = 19.3 W/kg
0 dB = 19.3 W/kg = 12.86 dBW/kg
Plot No. 11
Test Laboratory: UL Verification Services Inc. SAR Lab F
Date/Time: 8/6/2015 8:58:16 AM
20150806_SystemPerformanceCheck-D5GHzV2 SN 1168
Frequency: 5200 MHz; Duty Cycle: 1:1
Body/5.2 GHz, Pin=100mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 13.3 W/kg
Plot No. 12
Test Laboratory: UL Verification Services Inc. SAR Lab G
Date/Time: 7/23/2015 10:39:15 AM
20150723_SystemPerformanceCheck-D1750V2 SN 1077
Frequency: 1750 MHz; Duty Cycle: 1:1;
Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 1750 MHz; σ = 1.451 S/m; εr = 52.58; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1433; Calibrated: 3/12/2015
- Probe: EX3DV4 - SN3686; ConvF(7.28, 7.28, 7.28); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 A; Type: QDOVA002AA; Serial: 1258
Body/Pin=100 mW 2/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 4.93 W/kg
Body/Pin=100 mW 2/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 58.750 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 6.49 W/kg
SAR(1 g) = 3.7 W/kg; SAR(10 g) = 1.99 W/kg
Maximum value of SAR (measured) = 4.91 W/kg
0 dB = 4.91 W/kg = 6.91 dBW/kg
Plot No. 13
Test Laboratory: UL Verification Services Inc. SAR Lab G
Date/Time: 7/23/2015 10:57:48 AM
20150723_SystemPerformanceCheck-D1750V2 SN 1077
Frequency: 1750 MHz; Duty Cycle: 1:1
Body/Pin=100 mW 2/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 4.94 W/kg
Plot No. 14
Test Laboratory: UL Verification Services Inc. SAR Lab G
Date/Time: 7/27/2015 10:17:23 AM
20150727_SystemPerformanceCheck-D1750V2 SN 1050
Frequency: 1750 MHz; Duty Cycle: 1:1;
Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 1750 MHz; σ = 1.468 S/m; εr = 52.337; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1433; Calibrated: 3/12/2015
- Probe: EX3DV4 - SN3991; ConvF(8.01, 8.01, 8.01); Calibrated: 5/19/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 A; Type: QDOVA002AA; Serial: 1258
Body/Pin=100 mW 2/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 5.06 W/kg
Body/Pin=100 mW 2/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 59.362 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 6.73 W/kg
SAR(1 g) = 3.83 W/kg; SAR(10 g) = 2.05 W/kg
Maximum value of SAR (measured) = 5.12 W/kg
0 dB = 5.12 W/kg = 7.09 dBW/kg
Plot No. 15
Test Laboratory: UL Verification Services Inc. SAR Lab G
Date/Time: 7/27/2015 10:35:55 AM
20150727_SystemPerformanceCheck-D1750V2 SN 1050
Frequency: 1750 MHz; Duty Cycle: 1:1
Body/Pin=100 mW 2/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 5.07 W/kg
Plot No. 16
Test Laboratory: UL Verification Services Inc. SAR Lab G
Date/Time: 8/3/2015 9:51:58 AM
20150803_SystemPerformanceCheck-D5GHzV2 SN 1003
Frequency: 5600 MHz; Duty Cycle: 1:1;
Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 5600 MHz; σ = 5.911 S/m; εr = 48.098; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1433; Calibrated: 3/12/2015
- Probe: EX3DV4 - SN3991; ConvF(4.12, 4.12, 4.12); Calibrated: 5/19/2015;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1248
Body/5.6 GHz, Pin=100mW/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 21.1 W/kg
Body/5.6 GHz, Pin=100mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm
Reference Value = 52.538 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 38.3 W/kg
SAR(1 g) = 8.43 W/kg; SAR(10 g) = 2.34 W/kg
Maximum value of SAR (measured) = 21.2 W/kg
0 dB = 21.2 W/kg = 13.26 dBW/kg
Plot No. 17
Test Laboratory: UL Verification Services Inc. SAR Lab G
Date/Time: 8/3/2015 10:14:32 AM
20150803_SystemPerformanceCheck-D5GHzV2 SN 1003
Frequency: 5600 MHz; Duty Cycle: 1:1
Body/5.6 GHz, Pin=100mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 14.2 W/kg
Plot No. 18
Test Laboratory: UL Verification Services Inc. SAR Lab H
Date/Time: 7/27/2015 8:33:18 AM
20150727_SystemPerformanceCheck-D1900V2 SN 5d043
Frequency: 1900 MHz; Duty Cycle: 1:1;
Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 1900 MHz; σ = 1.523 S/m; εr = 52.222; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1472; Calibrated: 3/5/2015
- Probe: EX3DV4 - SN7335; ConvF(7.9, 7.9, 7.9); Calibrated: 3/13/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 A; Type: SM 000 T01 DA; Serial: TP:1247
Body/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 5.17 W/kg
Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 58.942 V/m; Power Drift = -0.00 dB
Peak SAR (extrapolated) = 7.00 W/kg
SAR(1 g) = 3.89 W/kg; SAR(10 g) = 2.04 W/kg
Maximum value of SAR (measured) = 5.21 W/kg
0 dB = 5.21 W/kg = 7.17 dBW/kg
Plot No. 19
Test Laboratory: UL Verification Services Inc. SAR Lab H
Date/Time: 7/27/2015 8:51:55 AM
20150727_SystemPerformanceCheck-D1900V2 SN 5d043
Frequency: 1900 MHz; Duty Cycle: 1:1
Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 5.16 W/kg
Plot No. 20
Test Laboratory: UL Verification Services Inc. SAR Lab H
Date/Time: 7/31/2015 2:57:01 PM
20150731_SystemPerformanceCheck-D5GHzV2 SN 1168
Frequency: 5800 MHz; Duty Cycle: 1:1;
Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 5800 MHz; σ = 5.914 S/m; εr = 46.426; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1472; Calibrated: 3/5/2015
- Probe: EX3DV4 - SN7335; ConvF(4.07, 4.07, 4.07); Calibrated: 3/13/2015;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1248
Body/5.8 GHz, Pin=100mW/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 18.9 W/kg
Body/5.8 GHz, Pin=100mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm
Reference Value = 49.911 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 32.9 W/kg
SAR(1 g) = 7.24 W/kg; SAR(10 g) = 2.06 W/kg
Maximum value of SAR (measured) = 17.9 W/kg
0 dB = 17.9 W/kg = 12.53 dBW/kg
Plot No. 21
Test Laboratory: UL Verification Services Inc. SAR Lab H
Date/Time: 7/31/2015 3:19:44 PM
20150731_SystemPerformanceCheck-D5GHzV2 SN 1168
Frequency: 5800 MHz; Duty Cycle: 1:1
Body/5.8 GHz, Pin=100mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 12.7 W/kg
Plot No. 22
Test Laboratory: UL Verification Services Inc. SAR Lab E
Date/Time: 9/14/2015 5:14:37 PM
20150914_SystemPerformanceCheck-D2450V2 SN 748
Frequency: 2450 MHz; Duty Cycle: 1:1;
Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 2450 MHz; σ = 1.987 S/m; εr = 51.856; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1439; Calibrated: 7/30/2015
- Probe: EX3DV4 - SN3772; ConvF(6.58, 6.58, 6.58); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 A; Type: QDOVA002AA; Serial: 1258
Body/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 5.46 W/kg
Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 59.926 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 10.4 W/kg
SAR(1 g) = 5.04 W/kg; SAR(10 g) = 2.34 W/kg
Maximum value of SAR (measured) = 7.17 W/kg
0 dB = 7.17 W/kg = 8.56 dBW/kg
Plot No. 23
Test Laboratory: UL Verification Services Inc. SAR Lab E
Date/Time: 9/14/2015 5:35:05 PM
20150914_SystemPerformanceCheck-D2450V2 SN 748
Frequency: 2450 MHz; Duty Cycle: 1:1
Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 7.09 W/kg
Plot No. 24
Download: A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Mirror Download [FCC.gov]A1652 Tablet Device RF Exposure Info SAR Appendix B Apple Inc.
Document ID2754552
Application IDy9IrhRcTJMHuReL1NjtYHA==
Document DescriptionSAR Appendix B
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize57.39kB (717317 bits)
Date Submitted2015-09-19 00:00:00
Date Available2015-10-15 00:00:00
Creation Date2015-09-15 13:55:37
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2015-09-15 13:55:37
Document TitleSAR Appendix B
Document CreatorMicrosoft® Word 2010
Document Author: John

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 24
Language                        : en-US
Tagged PDF                      : Yes
Title                           : Date/Time: 1/13/2011 12:26:38 AM, Date/Time: 1/13/2011 12:35:24 AM
Author                          : John
Creator                         : Microsoft® Word 2010
Create Date                     : 2015:09:15 13:55:37-07:00
Modify Date                     : 2015:09:15 13:55:37-07:00
Producer                        : Microsoft® Word 2010