FCC ID BDZ7250MHB
GoSafe 2 - Mobile Help Button (model 7250MHB) for a Personal Emergency System (PERS)
by Lifeline Systems Inc
Grantee Code: BDZ Product Code: 7250MHB
Latest application date: 2021-09-22
FCC ID Device Details
| FCC ID | BDZ7250MHB |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | BDZ |
| Product Code | 7250MHB |
| Applicant Business | Lifeline Systems Inc 🇺🇸 |
| Related Domains | |
| Equipment Class | GoSafe 2 - Mobile Help Button (model 7250MHB) for a Personal Emergency System (PERS) |
| Test Firm | Intertek Testing Services NA |
Linked Records
Barcode records decoded from published FCC label exhibits or linked by an explicit FCC ID reference on a product page.
| UPC / GTIN | Linked product |
|---|---|
| 884838093638 UPC-A · GTIN-14 00884838093638 | GoSafe 2 - Mobile Help Button (model 7250MHB) for a Personal Emergency System (PERS) Brand: Lifeline Systems Inc · Model: 7250MHB Source: FCC label |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Original Equipment | 2021-09-22 |
| 2402-2480 MHz | Original Equipment | 2021-09-22 |
| 2402-2480 MHz | Original Equipment | 2021-09-22 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| MANUAL | Users Manual | 2021-09-22 | PDF 2.5 MB |
| INTERNAL PHOTOS | Internal Photos | 2022-03-21 | PDF 640 KB |
| EXTERNAL PHOTOS | External Photos | 2021-09-22 | PDF 410.4 KB |
| LABEL AND LOCATION | ID Label/Location Info | 2021-09-22 | PDF 197.3 KB |
| TEST SETUP PHOTOS | Test Setup Photos | 2021-09-22 | PDF 1.2 MB |
| TEST REPORT | Test Report | 2021-09-22 | PDF 3.4 MB |
| TEST REPORT | Test Report | 2021-09-22 | PDF 3.3 MB |
| CONFIDENTIALITY REQUEST | Cover Letter(s) | 2021-09-22 | PDF 263.6 KB |
| RF EXHIBIT | RF Exposure Info | 2021-09-22 | PDF 4.6 MB |
| RF Exhibit | RF Exposure Info | 2021-09-22 | PDF 4.6 MB |
| BLOCK DIAGRAM Metadata only | Block Diagram | PDF 132.9 KB | |
| SCHEMATICS Metadata only | Schematics | PDF 376.4 KB | |
| OPERATIONAL DESCRIPTION Metadata only | Operational Description | PDF 445.7 KB | |
| OPERATIONAL DESCRIPTION Metadata only | Operational Description | PDF 222.1 KB | |
| SOFTWARE SECURITY REQUIREMENTS Metadata only | SDR Software/Security Inf | PDF 238.1 KB |
Application Information
| Application ID | z10rpoPfyFWxgsW0dOtAQA== |
|---|---|
| Final Action Date | 2021-09-22 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0014134019 |
| Model | 7250MHB |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | GoSafe 2 - Mobile Help Button (model 7250MHB) for a Personal Emergency System (PERS) |
| Responsible Party | Roberto Ballester, Principal Design Quality Engineer, Roberto.ballester@philips.com |
| Test Firm | James Sudduth, Intertek Testing Services NA, james.sudduth@intertek.com |
| TCB Email | tcb_admin@intertek.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 03/21/2022 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is Average conducted. This device is a portable device with respect to RF exposure compliance. DFS operation is slave without radar detection. This device supports 20 and 40 MHz bandwidth modes. The highest reported SAR for face, body, and extremity use conditions is 1.36 W/kg (10 mm), 1.40 W/kg (0 mm), and 1.98 W/kg (0 mm), respectively. This device contains FCC ID: XPY1DIQN3NN. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| z10rpoPfyFWxgsW0dOtAQA== | 2021-09-22 | Original Equipment |
| viZW0cbsgFdOE0X2L8gLag== | 2021-09-22 | Original Equipment |
| IqUs887l0Q+mdPy7tWRcJg== | 2021-09-22 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules | Grant Notes |
|---|---|---|---|
| 2402-2480 MHz | 0.0010000 | 15C | CC |
| 2402-2480 MHz | 0.001 | 15C | CC |
| 2412-2462 MHz | 0.012 | 15C | CC |
| 5180-5240 MHz | 0.0116 | 15E | CC, ND |
| 5180-5240 MHz | 0.0114 | 15E | CC, ND |
| 5190-5230 MHz | 0.0147 | 15E | CC, ND |
| 5260-5320 MHz | 0.0147 | 15E | CC, ND |
| 5260-5320 MHz | 0.0148 | 15E | CC, ND |
| 5270-5310 MHz | 0.0175 | 15E | CC, ND |
| 5745-5825 MHz | 0.0096 | 15E | CC, ND |
| 5745-5825 MHz | 0.0084 | 15E | CC, ND |
| 5755-5795 MHz | 0.0104 | 15E | CC, ND |
Grants
TCB Grant - Application z10rpoPfyFWxgsW0dOtAQA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Intertek Testing Services NA, Inc. 70 Codman Hill Road Boxborough, MA 01719 |
Date of Grant: 09/22/2021 Application Dated: 09/22/2021 |
| Lifeline Systems Inc |
| 111 Lawrence Street |
| Framingham, MA 01702 |
| Attention: Roberto Ballester , Principal Design Quality Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | BDZ7250MHB |
| Name of Grantee: | Lifeline Systems Inc |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | GoSafe 2 - Mobile Help Button (model 7250MHB) for a Personal Emergency System (PERS) |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC ND | 15E | 5180.0 - 5240.0 | 0.0116 | ||
| CC ND | 15E | 5180.0 - 5240.0 | 0.0114 | ||
| CC ND | 15E | 5190.0 - 5230.0 | 0.0147 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.0147 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.0148 | ||
| CC ND | 15E | 5270.0 - 5310.0 | 0.0175 | ||
| CC ND | 15E | 5745.0 - 5825.0 | 0.0096 | ||
| CC ND | 15E | 5745.0 - 5825.0 | 0.0084 | ||
| CC ND | 15E | 5755.0 - 5795.0 | 0.0104 |
| Output power listed is Average conducted. This device is a portable device with respect to RF exposure compliance. DFS operation is slave without radar detection. This device supports 20 and 40 MHz bandwidth modes. The highest reported SAR for face, body, and extremity use conditions is 1.36 W/kg (10 mm), 1.40 W/kg (0 mm), and 1.98 W/kg (0 mm), respectively. This device contains FCC ID: XPY1DIQN3NN. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application z10rpoPfyFWxgsW0dOtAQA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Lifeline Systems Inc 111 Lawrence Street Framingham, MA 01702 United States |
Date of Grant: 09/22/2021 Application Dated: 09/22/2021 |
| Attention: Roberto Ballester , Principal Design Quality Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | BDZ7250MHB |
| Name of Grantee: | Lifeline Systems Inc |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | GoSafe 2 - Mobile Help Button (model 7250MHB) for a Personal Emergency System (PERS) |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC ND | 15E | 5180.0 - 5240.0 | 0.0116 | ||
| CC ND | 15E | 5180.0 - 5240.0 | 0.0114 | ||
| CC ND | 15E | 5190.0 - 5230.0 | 0.0147 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.0147 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.0148 | ||
| CC ND | 15E | 5270.0 - 5310.0 | 0.0175 | ||
| CC ND | 15E | 5745.0 - 5825.0 | 0.0096 | ||
| CC ND | 15E | 5745.0 - 5825.0 | 0.0084 | ||
| CC ND | 15E | 5755.0 - 5795.0 | 0.0104 |
| Output power listed is Average conducted. This device is a portable device with respect to RF exposure compliance. DFS operation is slave without radar detection. This device supports 20 and 40 MHz bandwidth modes. The highest reported SAR for face, body, and extremity use conditions is 1.36 W/kg (10 mm), 1.40 W/kg (0 mm), and 1.98 W/kg (0 mm), respectively. This device contains FCC ID: XPY1DIQN3NN. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Intertek Testing Services NA, Inc. 70 Codman Hill Road Boxborough, MA 01719 |
Date of Grant: 09/22/2021 Application Dated: 09/22/2021 |
| Lifeline Systems Inc |
| 111 Lawrence Street |
| Framingham, MA 01702 |
| Attention: Roberto Ballester , Principal Design Quality Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | BDZ7250MHB |
| Name of Grantee: | Lifeline Systems Inc |
| Equipment Class: | Digital Transmission System |
| Notes: | GoSafe 2 - Mobile Help Button (model 7250MHB) for a Personal Emergency System (PERS) |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.012 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.001 |
| Output power listed is Peak conducted. This device is a portable device with respect to RF exposure compliance. The highest reported SAR for face, body, and extremity use conditions is 1.36 W/kg (10 mm), 1.40 W/kg (0 mm), and 1.98 W/kg (0 mm), respectively. This device contains FCC ID: XPY1DIQN3NN. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application viZW0cbsgFdOE0X2L8gLag==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Lifeline Systems Inc 111 Lawrence Street Framingham, MA 01702 United States |
Date of Grant: 09/22/2021 Application Dated: 09/22/2021 |
| Attention: Roberto Ballester , Principal Design Quality Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | BDZ7250MHB |
| Name of Grantee: | Lifeline Systems Inc |
| Equipment Class: | Digital Transmission System |
| Notes: | GoSafe 2 - Mobile Help Button (model 7250MHB) for a Personal Emergency System (PERS) |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.012 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.001 |
| Output power listed is Peak conducted. This device is a portable device with respect to RF exposure compliance. The highest reported SAR for face, body, and extremity use conditions is 1.36 W/kg (10 mm), 1.40 W/kg (0 mm), and 1.98 W/kg (0 mm), respectively. This device contains FCC ID: XPY1DIQN3NN. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Intertek Testing Services NA, Inc. 70 Codman Hill Road Boxborough, MA 01719 |
Date of Grant: 09/22/2021 Application Dated: 09/02/2021 |
| Lifeline Systems Inc |
| 111 Lawrence Street |
| Framingham, MA 01702 |
| Attention: Roberto Ballester , Principal Design Quality Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | BDZ7250MHB |
| Name of Grantee: | Lifeline Systems Inc |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | GoSafe 2 - Mobile Help Button (model 7250MHB) for a Personal Emergency System (PERS) |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.001 |
| Output power listed is Peak conducted. This device is a portable device with respect to RF exposure compliance. The highest reported SAR for face, body, and extremity use conditions is 1.36 W/kg (10 mm), 1.40 W/kg (0 mm), and 1.98 W/kg (0 mm), respectively. This device contains FCC ID: XPY1DIQN3N. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application IqUs887l0Q+mdPy7tWRcJg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Lifeline Systems Inc 111 Lawrence Street Framingham, MA 01702 United States |
Date of Grant: 09/22/2021 Application Dated: 09/02/2021 |
| Attention: Roberto Ballester , Principal Design Quality Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | BDZ7250MHB |
| Name of Grantee: | Lifeline Systems Inc |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | GoSafe 2 - Mobile Help Button (model 7250MHB) for a Personal Emergency System (PERS) |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.001 |
| Output power listed is Peak conducted. This device is a portable device with respect to RF exposure compliance. The highest reported SAR for face, body, and extremity use conditions is 1.36 W/kg (10 mm), 1.40 W/kg (0 mm), and 1.98 W/kg (0 mm), respectively. This device contains FCC ID: XPY1DIQN3N. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |