FCC ID BEJLSI120R

Cellphone

by LG Electronics USA

Grantee Code: BEJ   Product Code: LSI120R
Latest application date: 2005-11-18

FCC ID Device Details

FCC IDBEJLSI120R
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeBEJ
Product CodeLSI120R
Applicant BusinessLG Electronics USA 🇺🇸
Related Domains lge.com
Equipment ClassCellphone
Test FirmESTECH Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.7-848.31 MHzOriginal Equipment2005-11-18

Exhibits

DocumentTypeAvailableFile
Users Manual RevisedUsers Manual2006-01-02PDF 1.7 MB
Internal PhotosInternal Photos2006-01-02PDF 2 MB
External PhotosExternal Photos2006-01-02PDF 400.3 KB
Label InformationID Label/Location Info2005-11-18PDF 71.1 KB
Test PhotosTest Setup Photos2006-01-02PDF 433.4 KB
Test ReportTest Report2005-11-18PDF 244.5 KB
Additional CDMA DiscussionCover Letter(s)2005-11-18PDF 132.8 KB
CDMA Discussion Part 1ACover Letter(s)2005-11-18PDF 67 KB
CDMA Discussion Part 1BCover Letter(s)2005-11-18PDF 21.8 KB
CDMA Discussion Part 1CCover Letter(s)2005-11-18PDF 38.4 KB
CommentsCover Letter(s)2005-11-18PDF 60.7 KB
Confidentiality LetterCover Letter(s)2005-11-18PDF 52 KB
FCC Inquiry 1 DiscussionCover Letter(s)2005-11-18PDF 70.6 KB
FCC Inquiry 2 DiscussionCover Letter(s)2005-11-18PDF 46 KB
ResponseCover Letter(s)2005-11-18PDF 30.1 KB
Short Term Confidentiality LetterCover Letter(s)2005-11-18PDF 18.3 KB
SAR Report Part 1 RevisedRF Exposure Info2005-11-18PDF 3 MB
SAR Report Part 2 RevisedRF Exposure Info2005-11-18PDF 3.1 MB
Block Diagram Metadata onlyBlock DiagramPDF 78.4 KB
Schematics Metadata onlySchematicsPDF 171.5 KB
Operational and Tune Up Description Metadata onlyOperational DescriptionPDF 144.3 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 66.2 KB

Application Information

Application IDhl7+HCX5yS7XREakISpDKw==
Final Action Date2005-11-18
Application PurposeOriginal Equipment
Applicant FRN0020917688
ModelLSI120R
Frequency Range824.7-848.31 MHz
Equipment ClassTNE - Licensed Non-Broadcast Transmitter Held to Ear
Device DescriptionCellphone
Responsible PartySung Soo Kim, Director, Regulatory and Environmental Affairs, sungsoo.kim@lge.com , 201-266-2215
AgentJay Jay Jay, EStech, jaykim@estech.co.kr , 82-2-867-3201
Technical ContactJay Kim, LG Electronics, jaykim@estech.co.kr , 82-2-867-3201
Test FirmYang Jinmo, ESTECH Co., Ltd., jmyang@estech.co.kr , 82-31-631-8037
TCB Emailhotline@AmericanTCB.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Short-Term Confidentiality Date01/02/2006
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is ERP. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user’s body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.29 W/kg; Body-worn 0.95 W/kg

Applications

Application IDDatePurpose
hl7+HCX5yS7XREakISpDKw==2005-11-18Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.7-848.31 MHz0.23300002.5000000000ppm1M25F9W22H

Grants

TCB Grant - Application hl7+HCX5yS7XREakISpDKw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 11/18/2005

Application Dated: 11/18/2005
LG Electronics USA
111 Sylvan Avenue
North Building
Englewood Cliffs, NJ 07632
 
Attention: Sung Soo Kim , Director, Regulatory and Environmental Affairs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  BEJLSI120R
Name of Grantee:  LG Electronics USA
Equipment Class: Licensed Non-Broadcast Transmitter Held to Ear
Notes: Cellphone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.233 2.5  PM 1M25F9W

Power Output is ERP. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user’s body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.29 W/kg; Body-worn 0.95 W/kg

EAS Grant - Application hl7+HCX5yS7XREakISpDKw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

LG Electronics USA
111 Sylvan Avenue North Building
Englewood Cliffs, NJ 07632
United States
  Date of Grant: 11/18/2005

Application Dated: 11/18/2005
 
Attention: Sung Soo Kim , Director, Regulatory and Environmental Affairs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  BEJLSI120R
Name of Grantee:  LG Electronics USA
Equipment Class: Licensed Non-Broadcast Transmitter Held to Ear
Notes: Cellphone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.233 2.5  PM 1M25F9W

Power Output is ERP. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user’s body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.29 W/kg; Body-worn 0.95 W/kg



Mail To: