FCC ID CGDRELAY

Communication repeater for Sensit sensors

by Nedap N. V.

Grantee Code: CGD   Product Code: RELAY
Latest application date: 2014-08-12

FCC ID Device Details

FCC IDCGDRELAY
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeCGD
Product CodeRELAY
Applicant BusinessNedap N. V. 🇳🇱
Related Domains nedap.com
Equipment ClassCommunication repeater for Sensit sensors
Test FirmTUV Rheinland Nederland B.V.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.4-927.6 MHzOriginal Equipment2014-08-12

Exhibits

DocumentTypeAvailableFile
14r01_SENSIT Install Guide v1 4 2_2 Mb CGDRELAYUsers Manual2014-08-12PDF 2.4 MB
17_Statement 15.19_3 in manual CGDRELAYCover Letter(s)2014-08-12PDF 548.7 KB
08_Photo Interior CGDRELAYInternal Photos2014-08-12PDF 439.5 KB
09_Photo Exterior CGDRELAYExternal Photos2014-08-12PDF 237.5 KB
10r01_Label_position CGDRELAYID Label/Location Info2014-08-12PDF 184.5 KB
13r01_14013102_Rev01_Photo Testsetup CGDRELAYTest Setup Photos2014-08-12PDF 794.4 KB
12r02_14013102.fcc01_Rev01 CGDRELAYTest Report2014-08-12PDF 1,005.1 KB
01_Cover letter CGDRELAYCover Letter(s)2014-08-12PDF 543.9 KB
02-Request of Confidentiality CGDRELAYCover Letter(s)2014-08-12PDF 544.4 KB
18_Tracking number 966041 CGDRELAYCover Letter(s)2014-08-12PDF 55.2 KB
16r01_RF Exposure CGDRELAYRF Exposure Info2014-08-12PDF 554.3 KB
Confidential_07r02_Block diagram CGDRELAY Metadata onlyBlock DiagramPDF 592.1 KB
Confidential_06_SchematicT5076013 CGDRELAY Metadata onlySchematicsPDF 937.6 KB
04r01_Antenna CGDRELAY Metadata onlyOperational DescriptionPDF 1,024 KB
15_Data sheetnRF905 Sensit CGDRELAY Metadata onlyOperational DescriptionPDF 501.4 KB
Confidential_11r01_Operational Description CGDRELAY Metadata onlyOperational DescriptionPDF 100.4 KB
Confidential_05_BoM T5076013 CGDRELAY Metadata onlyParts List/Tune Up InfoPDF 75.7 KB

Application Information

Application IDw1m/8RA6yFkw5/VVWMAqaA==
Final Action Date2014-08-12
Application PurposeOriginal Equipment
Applicant FRN0007696149
ModelRELAY
Frequency Range902.4-927.6 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionCommunication repeater for Sensit sensors
Responsible PartyReinold Hubers, Approbation Officer, reinold.hubers@nedap.com , 0031544471111
Technical ContactJacques Hulshof, N.V. Nederlandsche Apparatenfabriek Nedap, Jacques.Hulshof@nedap.com , 0113154471111
Non-Technical ContactJacques Hulshof, N.V. Nederlandsche Apparatenfabriek Nedap, Jacques.Hulshof@nedap.com , 0113154471111
Test FirmRichard van der Meer, TUV Rheinland Nederland B.V., richard.vandermeer@nl.tuv.com , 31-088-888-7888
TCB Emailhotline@acbcert.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsPower Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any other antenna(s) or transmitter(s). End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
w1m/8RA6yFkw5/VVWMAqaA==2014-08-12Original Equipment

Equipment Authorization

FrequencyOutputRules
902.4-927.6 MHz0.010700015C

Grants

TCB Grant - Application w1m/8RA6yFkw5/VVWMAqaA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 08/12/2014

Application Dated: 08/12/2014
Nedap N. V.
Parallelweg 2
Groenlo, 7141 DC
Netherlands
 
Attention: Reinold Hubers , Approbation Officer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CGDRELAY
Name of Grantee:  Nedap N. V.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Communication repeater for Sensit sensors
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.4  -  927.6 0.0107  

Power Output listed is conducted.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any other antenna(s) or transmitter(s).

End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


EAS Grant - Application w1m/8RA6yFkw5/VVWMAqaA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Nedap N. V.
Parallelweg 2
Groenlo, 7141 DC
Netherlands
  Date of Grant: 08/12/2014

Application Dated: 08/12/2014
 
Attention: Reinold Hubers , Approbation Officer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CGDRELAY
Name of Grantee:  Nedap N. V.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Communication repeater for Sensit sensors
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.4  -  927.6 0.0107  

Power Output listed is conducted.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any other antenna(s) or transmitter(s).

End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: