FCC ID CKLHGC-310
Dual-Mode Cellular Phone (AMPS/CDMA)
by Hyundai Electronics Industries Co Ltd
Grantee Code: CKL Product Code: HGC310
Latest application date: 2000-12-11
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.04-848.97 MHz | Original Equipment | 2000-12-11 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Revised Users Manual Page | Users Manual | 2000-12-11 | PDF 42.6 KB |
| Users Manual | Users Manual | 2000-12-11 | PDF 2.2 MB |
| Internal Photos | Internal Photos | 2000-12-11 | PDF 1 MB |
| External Photos | External Photos | 2000-12-11 | PDF 1.4 MB |
| FCC ID Label and Location | ID Label/Location Info | 2000-12-11 | PDF 141 KB |
| Antenna Specifications | Operational Description | 2000-12-11 | PDF 1.3 MB |
| SAR Test Setup Photos | RF Exposure Info | 2000-12-11 | PDF 735.4 KB |
| Test Setup Photos | Test Setup Photos | 2000-12-11 | PDF 1,015.2 KB |
| Audio Modulation Plots | Test Report | 2000-12-11 | PDF 26.9 KB |
| SAR Test Report | RF Exposure Info | 2000-12-11 | PDF 612.3 KB |
| Test Plots | Test Report | 2000-12-11 | PDF 1.3 MB |
| Test Report | Test Report | 2000-12-11 | PDF 284.2 KB |
| Attestation Statements | Attestation Statements | 2000-12-11 | PDF 307.8 KB |
| Cover Letter | Cover Letter(s) | 2000-12-11 | PDF 477.7 KB |
| Body SAR Test Data | RF Exposure Info | 2000-12-11 | PDF 969.4 KB |
| Dipole Validation | RF Exposure Info | 2000-12-11 | PDF 175.3 KB |
| Head SAR Test Data | RF Exposure Info | 2000-12-11 | PDF 649.7 KB |
| Probe Calibration | RF Exposure Info | 2000-12-11 | PDF 145.1 KB |
| RF Exposure Warning Statement | RF Exposure Info | 2000-12-11 | PDF 815.9 KB |
| Block Diagram Metadata only | Block Diagram | PDF 111.4 KB | |
| Schematic Diagrams Metadata only | Schematics | PDF 528 KB | |
| Operational Description Metadata only | Operational Description | PDF 252.3 KB | |
| Parts List and Tune Up Procedure Metadata only | Parts List/Tune Up Info | PDF 2.1 MB |
Application Information
| Application ID | 8x4k7S3VJWI1vJx2JLJX9g== |
|---|---|
| Final Action Date | 2000-12-11 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0003758679 |
| Model | HGC-310 |
| Frequency Range | 824.04-848.97 MHz |
| Equipment Class | TNE - Licensed Non-Broadcast Transmitter Held to Ear |
| Device Description | Dual-Mode Cellular Phone (AMPS/CDMA) |
| Responsible Party | Bong Jae Hur, Manager, QA Office, kisookim@hei.co.kr |
| Agent | Randy Randy Randy, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com |
| Technical Contact | Randy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com |
| Non-Technical Contact | Randy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output is ERP. For AMPS mode operations, units produced must not exceed 603 mW conducted output, as tested for this filing, for satisfying RF exposure compliance. SAR compliance for body-worn operating configurations is limited to the specific belt-clip/leather-case tested for the filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 1.47 W/kg; Body-worn: 0.5 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 8x4k7S3VJWI1vJx2JLJX9g== | 2000-12-11 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application 8x4k7S3VJWI1vJx2JLJX9g==
This application does not exist.
EAS Grant - Application 8x4k7S3VJWI1vJx2JLJX9g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hyundai Electronics Industries Co Ltd San 136-1, Ami-Ri Bubal-Eub, Ichon-Si Kyoungki-Do, 467-701 South Korea |
Date of Grant: 12/11/2000 Application Dated: 10/18/2000 |
| Attention: Bong Hur , Manager, QA Office |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | CKLHGC-310 |
| Name of Grantee: | Hyundai Electronics Industries Co Ltd |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Ear |
| Notes: | Dual-Mode Cellular Phone (AMPS/CDMA) |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.04 - 848.97 | 0.6 | 2.5 PM | 40K0F8W | |
| 22H | 824.04 - 848.97 | 0.6 | 2.5 PM | 40K0F1D | |
| 22.901(d) | 824.7 - 848.31 | 0.443 | 2.5 PM | 1M25F9W |
| Output is ERP. For AMPS mode operations, units produced must not exceed 603 mW conducted output, as tested for this filing, for satisfying RF exposure compliance. SAR compliance for body-worn operating configurations is limited to the specific belt-clip/leather-case tested for the filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 1.47 W/kg; Body-worn: 0.5 W/kg. |
| Mail To: |
| Randy Ortanez, President |
| PCTEST Engineering Laboratory, Inc. |
| 6660-B Dobbin Road |
| Columbia, MD 21045 |