FCC ID CKLHGC-310E
Dual Mode Cellular Phone (AMPS/CDMA)
by Hyundai Electronics Industries Co Ltd
Grantee Code: CKL Product Code: HGC310E
Latest application date: 2000-08-17
FCC ID Device Details
| FCC ID | CKLHGC-310E |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | CKL |
| Product Code | HGC310E |
| Applicant Business | Hyundai Electronics Industries Co Ltd 🇰🇷 |
| Related Domains | |
| Equipment Class | Dual Mode Cellular Phone (AMPS/CDMA) |
| Test Firm | PCTEST Engineering Laboratory, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.04-848.97 MHz | Original Equipment | 2000-08-17 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| RF exposure manual warning page | RF Exposure Info | 2000-08-17 | PDF 11.1 KB |
| Users Manual | Users Manual | 2000-08-17 | PDF 5.1 MB |
| Internal Photos | Internal Photos | 2000-08-17 | PDF 1,008.6 KB |
| External Photos | External Photos | 2000-08-17 | PDF 1.1 MB |
| Sample Label and Location | ID Label/Location Info | 2000-08-17 | PDF 171.7 KB |
| Antenna Specifications | Operational Description | 2000-08-17 | PDF 3.2 MB |
| test setup photos | Test Setup Photos | 2000-08-17 | PDF 548.8 KB |
| test report test plots and modulation plots | Test Report | 2000-08-17 | PDF 4.2 MB |
| Authorization Confidentiality E911 and ESN Letters | Attestation Statements | 2000-08-17 | PDF 621.2 KB |
| Cover Letter | Cover Letter(s) | 2000-08-17 | PDF 32.8 KB |
| Dipole Validation | RF Exposure Info | 2000-08-17 | PDF 173.5 KB |
| Probe Calibration | RF Exposure Info | 2000-08-17 | PDF 143.7 KB |
| RF Exposure Warning Statement | RF Exposure Info | 2000-08-17 | PDF 16.7 KB |
| SAR Head Body and Holster Photos | RF Exposure Info | 2000-08-17 | PDF 1.8 MB |
| SAR Report Head Body SAR Data | RF Exposure Info | 2000-08-17 | PDF 613.4 KB |
| SAR Test Plots | RF Exposure Info | 2000-08-17 | PDF 2.5 MB |
| Block Diagram Metadata only | Block Diagram | PDF 219.9 KB | |
| Schematics Metadata only | Schematics | PDF 1.4 MB | |
| Operational Description Metadata only | Operational Description | PDF 636.5 KB | |
| Part Lists and Tune Up Procedures Metadata only | Parts List/Tune Up Info | PDF 4.8 MB |
Application Information
| Application ID | S1gWY4KeKU0ZWP8huDsjQg== |
|---|---|
| Final Action Date | 2000-08-17 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0003758679 |
| Model | HGC-310E |
| Frequency Range | 824.04-848.97 MHz |
| Equipment Class | TNE - Licensed Non-Broadcast Transmitter Held to Ear |
| Device Description | Dual Mode Cellular Phone (AMPS/CDMA) |
| Responsible Party | Bong Jae Hur, Manager, QA Office, kisookim@hei.co.kr |
| Agent | Randy Randy Randy, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com |
| Technical Contact | Randy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com |
| Non-Technical Contact | Randy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com |
| Test Firm | Randy Ortanez, PCTEST Engineering Laboratory, Inc., ro@pctestlab.com |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output is ERP. For AMPS mode operation, units produced must not exceed 600 mW conducted output, as tested for this filing, for satisfying RF exposure requirement. SAR compliance for body-worn operating configurations is limited to the specific configurations, including a specific leather-case, tested for this filing. Other belt-clips, holsters or similar accessories used with this device for body-worn operations must not contain any metallic component in the assembly and must provide at least 2.0 cm separation between the device, including its antenna whether extended or retracted, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 1.09 W/kg, Body-worn: 0.66 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| S1gWY4KeKU0ZWP8huDsjQg== | 2000-08-17 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application S1gWY4KeKU0ZWP8huDsjQg==
This application does not exist.
EAS Grant - Application S1gWY4KeKU0ZWP8huDsjQg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hyundai Electronics Industries Co Ltd San 136-1, Ami-Ri Bubal-Eub, Ichon-Si Kyoungki-Do, 467-701 South Korea |
Date of Grant: 08/17/2000 Application Dated: 06/19/2000 |
| Attention: Bong Hur , Manager, QA Office |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | CKLHGC-310E |
| Name of Grantee: | Hyundai Electronics Industries Co Ltd |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Ear |
| Notes: | Dual Mode Cellular Phone (AMPS/CDMA) |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.04 - 848.97 | 0.6 | 2.5 PM | 40K0F8W |
| BC | 22H | 824.04 - 848.97 | 0.6 | 2.5 PM | 40K0F1D |
| 22.901(d) | 824.7 - 848.31 | 0.322 | 2.5 PM | 1M25F9W |
| Output is ERP. For AMPS mode operation, units produced must not exceed 600 mW conducted output, as tested for this filing, for satisfying RF exposure requirement. SAR compliance for body-worn operating configurations is limited to the specific configurations, including a specific leather-case, tested for this filing. Other belt-clips, holsters or similar accessories used with this device for body-worn operations must not contain any metallic component in the assembly and must provide at least 2.0 cm separation between the device, including its antenna whether extended or retracted, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are - Head: 1.09 W/kg, Body-worn: 0.66 W/kg. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
| Mail To: |
| Randy Ortanez, President |
| PCTEST Engineering Laboratory, Inc. |
| 6660-B Dobbin Road |
| Columbia, MD 21045 |