FCC ID CLNM4WILINK1

M4 WiLink1

by MFOURTEL MEXICO S.A. DE C.V.

Grantee Code: CLN   Product Code: M4WILINK1
Latest application date: 2018-07-31

FCC ID Device Details

FCC IDCLNM4WILINK1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeCLN
Product CodeM4WILINK1
Applicant BusinessMFOURTEL MEXICO S.A. DE C.V. 🇲🇽
Related Domains m4tel.com
Equipment ClassM4 WiLink1
Test FirmBay Area Compliance Laboratories Corp. (Shenzhen)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2018-07-31
824.2-848.8 MHzOriginal Equipment2018-07-31

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2018-07-31PDF 649.7 KB
Int PhotosInternal Photos2018-07-31PDF 4 MB
Ext PhotosExternal Photos2018-07-31PDF 630.3 KB
FCC ID LabelID Label/Location Info2018-07-31PDF 173.3 KB
Setup PhotosTest Setup Photos2018-07-31PDF 313.6 KB
Setup PhotosTest Setup Photos2018-07-31PDF 209.1 KB
Test ReportTest Report2018-07-31PDF 1.2 MB
Test ReportTest Report2018-07-31PDF 441.4 KB
Test ReportTest Report2018-07-31PDF 2.2 MB
Attestation LetterAttestation Statements2018-07-31PDF 13.4 KB
Confidentiality LetterCover Letter(s)2018-07-31PDF 18.1 KB
POACover Letter(s)2018-07-31PDF 13.9 KB
RF ExposureRF Exposure Info2018-07-31PDF 59.4 KB
RF ExposureRF Exposure Info2018-07-31PDF 100.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 342.1 KB
Schematics Metadata onlySchematicsPDF 250.3 KB
Operation Description Metadata onlyOperational DescriptionPDF 166.7 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 60.4 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 421.8 KB

Application Information

Application IDlGAzaxjR4DcuYq3Obh+gRA==
Final Action Date2018-07-31
Application PurposeOriginal Equipment
Applicant FRN0021559117
ModelM4WILINK1
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionM4 WiLink1
Responsible PartyXin Li, Xin.Li@m4tel.com , 00886075526739633
Test FirmWell Wang, Bay Area Compliance Laboratories Corp. (Shenzhen), qa.sz@baclcorp.com , +86 (0) 755 33320018
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. The device supports 20 MHz and 40 MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
lGAzaxjR4DcuYq3Obh+gRA==2018-07-31Original Equipment
S4iw28JBnNS5Vmi6NTfMWg==2018-07-31Original Equipment
O7WQBEw1OVlCaLoPb+kP1Q==2018-07-31Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
15BCC
824.7-848.3 MHz0.1912.5ppm1M10G7D22H
824.7-848.3 MHz0.1822.5ppm1M11D7W22H
826.4-846.6 MHz0.1822.5ppm4M12F9W22H
829-844 MHz0.1612.5ppm8M91D7W22H
829-844 MHz0.1672.5ppm8M97G7D22H
1711.5-1753.5 MHz0.1932.5ppm2M70G7D27
1711.5-1753.5 MHz0.22.5ppm2M69D7W27
1712.5-1752.5 MHz0.2032.5ppm4M49G7D27
1712.5-1752.5 MHz0.192.5ppm4M49D7W27
1720-1745 MHz0.1612.5ppm17M9G7D27
1720-1745 MHz0.1592.5ppm17M9D7W27
1850.2-1909.8 MHz1.0352.5ppm248KGXW24E
1850.2-1909.8 MHz0.3242.5ppm244KG7W24E
1852.4-1907.6 MHz0.1582.5ppm4M12F9W24E
2412-2462 MHz0.107000015CCC, MO
2505-2565 MHz0.1972.5ppm8M97G7D27
2505-2565 MHz0.1912.5ppm8M97D7W27
2510-2560 MHz0.1742.5ppm17M9G7D27
2510-2560 MHz0.1642.5ppm17M9D7W27

Grants

TCB Grant - Application S4iw28JBnNS5Vmi6NTfMWg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 07/31/2018

Application Dated: 07/31/2018
MFOURTEL MEXICO S.A. DE C.V.
Av. Ejercito Nacional 436 Piso 3 Chapultepec
Morales Miguel Hidalgo D.F 11570
Mexico,
Mexico
 
Attention: Xin Li

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CLNM4WILINK1
Name of Grantee:  MFOURTEL MEXICO S.A. DE C.V.
Equipment Class: PCS Licensed Transmitter
Notes: M4 WiLink1
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.875 2.5  PM 244KGXW
22H 824.2  -  848.8 0.512 2.5  PM 244KG7W
22H 826.4  -  846.6 0.182 2.5  PM 4M12F9W
24E 1850.2  -  1909.8 1.035 2.5  PM 248KGXW
24E 1850.2  -  1909.8 0.324 2.5  PM 244KG7W
24E 1852.4  -  1907.6 0.158 2.5  PM 4M12F9W
22H 824.7  -  848.3 0.191 2.5  PM 1M10G7D
22H 824.7  -  848.3 0.182 2.5  PM 1M11D7W
22H 829.0  -  844.0 0.167 2.5  PM 8M97G7D
22H 829.0  -  844.0 0.161 2.5  PM 8M91D7W
27 2505.0  -  2565.0 0.197 2.5  PM 8M97G7D
27 2505.0  -  2565.0 0.191 2.5  PM 8M97D7W
27 2510.0  -  2560.0 0.174 2.5  PM 17M9G7D
27 2510.0  -  2560.0 0.164 2.5  PM 17M9D7W
27 1711.5  -  1753.5 0.193 2.5  PM 2M70G7D
27 1711.5  -  1753.5 0.2 2.5  PM 2M69D7W
27 1712.5  -  1752.5 0.203 2.5  PM 4M49G7D
27 1712.5  -  1752.5 0.19 2.5  PM 4M49D7W
27 1720.0  -  1745.0 0.161 2.5  PM 17M9G7D
27 1720.0  -  1745.0 0.159 2.5  PM 17M9D7W

Output power listed is conducted. LTE supports 1.4/3/5/10/15/20 MHz BW modes in Band 4,1.4/3/5/10 MHz BW modes in Band 5, and 5/10/15/20 MHz BW modes in Band 7. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

This device contains functions that are not operational in U.S. and its Territories. This filing is only applicable for US operations.


EAS Grant - Application S4iw28JBnNS5Vmi6NTfMWg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

MFOURTEL MEXICO S.A. DE C.V.
Av. Ejercito Nacional 436 Piso 3 Chapultepec Morales Miguel Hidalgo D.F 11570
Mexico,
Mexico
  Date of Grant: 07/31/2018

Application Dated: 07/31/2018
 
Attention: Xin Li

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CLNM4WILINK1
Name of Grantee:  MFOURTEL MEXICO S.A. DE C.V.
Equipment Class: PCS Licensed Transmitter
Notes: M4 WiLink1
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.875 2.5  PM 244KGXW
22H 824.2  -  848.8 0.512 2.5  PM 244KG7W
22H 826.4  -  846.6 0.182 2.5  PM 4M12F9W
24E 1850.2  -  1909.8 1.035 2.5  PM 248KGXW
24E 1850.2  -  1909.8 0.324 2.5  PM 244KG7W
24E 1852.4  -  1907.6 0.158 2.5  PM 4M12F9W
22H 824.7  -  848.3 0.191 2.5  PM 1M10G7D
22H 824.7  -  848.3 0.182 2.5  PM 1M11D7W
22H 829.0  -  844.0 0.167 2.5  PM 8M97G7D
22H 829.0  -  844.0 0.161 2.5  PM 8M91D7W
27 2505.0  -  2565.0 0.197 2.5  PM 8M97G7D
27 2505.0  -  2565.0 0.191 2.5  PM 8M97D7W
27 2510.0  -  2560.0 0.174 2.5  PM 17M9G7D
27 2510.0  -  2560.0 0.164 2.5  PM 17M9D7W
27 1711.5  -  1753.5 0.193 2.5  PM 2M70G7D
27 1711.5  -  1753.5 0.2 2.5  PM 2M69D7W
27 1712.5  -  1752.5 0.203 2.5  PM 4M49G7D
27 1712.5  -  1752.5 0.19 2.5  PM 4M49D7W
27 1720.0  -  1745.0 0.161 2.5  PM 17M9G7D
27 1720.0  -  1745.0 0.159 2.5  PM 17M9D7W

Output power listed is conducted. LTE supports 1.4/3/5/10/15/20 MHz BW modes in Band 4,1.4/3/5/10 MHz BW modes in Band 5, and 5/10/15/20 MHz BW modes in Band 7. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

This device contains functions that are not operational in U.S. and its Territories. This filing is only applicable for US operations.



TCB Grant - Application O7WQBEw1OVlCaLoPb+kP1Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 07/31/2018

Application Dated: 07/31/2018
MFOURTEL MEXICO S.A. DE C.V.
Av. Ejercito Nacional 436 Piso 3 Chapultepec
Morales Miguel Hidalgo D.F 11570
Mexico,
Mexico
 
Attention: Xin Li

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CLNM4WILINK1
Name of Grantee:  MFOURTEL MEXICO S.A. DE C.V.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: M4 WiLink1
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application O7WQBEw1OVlCaLoPb+kP1Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

MFOURTEL MEXICO S.A. DE C.V.
Av. Ejercito Nacional 436 Piso 3 Chapultepec Morales Miguel Hidalgo D.F 11570
Mexico,
Mexico
  Date of Grant: 07/31/2018

Application Dated: 07/31/2018
 
Attention: Xin Li

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CLNM4WILINK1
Name of Grantee:  MFOURTEL MEXICO S.A. DE C.V.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: M4 WiLink1
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application lGAzaxjR4DcuYq3Obh+gRA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 07/31/2018

Application Dated: 07/31/2018
MFOURTEL MEXICO S.A. DE C.V.
Av. Ejercito Nacional 436 Piso 3 Chapultepec
Morales Miguel Hidalgo D.F 11570
Mexico,
Mexico
 
Attention: Xin Li

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CLNM4WILINK1
Name of Grantee:  MFOURTEL MEXICO S.A. DE C.V.
Equipment Class: Digital Transmission System
Notes: M4 WiLink1
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.107  

Output power listed is conducted. The device supports 20 MHz and 40 MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application lGAzaxjR4DcuYq3Obh+gRA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

MFOURTEL MEXICO S.A. DE C.V.
Av. Ejercito Nacional 436 Piso 3 Chapultepec Morales Miguel Hidalgo D.F 11570
Mexico,
Mexico
  Date of Grant: 07/31/2018

Application Dated: 07/31/2018
 
Attention: Xin Li

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CLNM4WILINK1
Name of Grantee:  MFOURTEL MEXICO S.A. DE C.V.
Equipment Class: Digital Transmission System
Notes: M4 WiLink1
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.107  

Output power listed is conducted. The device supports 20 MHz and 40 MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: