FCC ID CN289693

LRMII TRANSCEIVER MODULE

by Cattron North America Inc.

Grantee Code: CN2   Product Code: 89693
Latest application date: 2019-04-16

FCC ID Device Details

FCC IDCN289693
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeCN2
Product Code89693
Applicant BusinessCattron North America Inc. 🇺🇸
Related Domains cattron.com
Equipment ClassLRMII TRANSCEIVER MODULE
Test FirmTimco Engineering, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-470 MHzOriginal Equipment2019-04-16

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2019-10-13PDF 397.7 KB
Internal PhotosInternal Photos2019-04-16PDF 438 KB
External PhotosExternal Photos2019-04-16PDF 437.5 KB
Label InfoID Label/Location Info2019-04-16PDF 115 KB
Test Setup PhotosTest Setup Photos2019-10-13PDF 255.5 KB
Test ReportTest Report2019-04-16PDF 453.7 KB
Confidential Request LetterCover Letter(s)2019-04-16PDF 783.9 KB
Extended Frequencies Justification LetterCover Letter(s)2019-04-16PDF 644.1 KB
Modular Approval LetterCover Letter(s)2019-04-16PDF 1.1 MB
POACover Letter(s)2019-04-16PDF 385.7 KB
MPE ReportRF Exposure Info2019-04-16PDF 109.8 KB
Tuning ProcedureParts List/Tune Up Info2019-04-16PDF 88.1 KB
Block Diagram Metadata onlyBlock DiagramPDF 256.9 KB
Schematics Metadata onlySchematicsPDF 328.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 309.6 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 87.8 KB

Application Information

Application ID6BgKNCMliY2PJrZ93jFXzQ==
Final Action Date2019-04-16
Application PurposeOriginal Equipment
Applicant FRN0003181625
Model89693
Frequency Range450-470 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionLRMII TRANSCEIVER MODULE
Responsible PartyDavid Stagg, Product Manager, david.stagg@cattron.com , 826-674-9780
Test FirmBruno Clavier, Timco Engineering, Inc., bruno@timcoengr.com , 352-472-5500
TCB Emailtei@timcoengr.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date10/13/2019
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsSingle Modular Approval. Power listed is conducted. This device is to be used only for mobile and fixed applications. The maximum antenna gain for this device as reported to the FCC is 4.15dBi. The module antenna must be installed to meet the RF exposure compliance separation distance of 20 cm and any additional testing and authorization process as required. Co-location of this module with other transmitters that operate simultaneously is required to be evaluated using the FCC multi-transmitter procedures. OEM integrators and end-Users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations.

Applications

Application IDDatePurpose
6BgKNCMliY2PJrZ93jFXzQ==2019-04-16Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
450-470 MHz0.0010.444ppm8K12F1D9EF
450-470 MHz0.0010.444ppm8K12F1W9EF
450-470 MHz0.0010.444ppm8K12F1X9EF
450-470 MHz0.010.444ppm8K12F1D9EF
450-470 MHz0.010.444ppm8K12F1W9EF
450-470 MHz0.010.444ppm8K12F1X9EF
450-470 MHz0.10.444ppm8K12F1D9EF
450-470 MHz0.10.444ppm8K12F1W9EF
450-470 MHz0.10.444ppm8K12F1X9EF

Grants

TCB Grant - Application 6BgKNCMliY2PJrZ93jFXzQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 04/16/2019

Application Dated: 04/16/2019
Cattron North America Inc.
655 N. River Road NW
Suite A
Warren, OH 44483-2254
 
Attention: David Stagg , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CN289693
Name of Grantee:  Cattron North America Inc.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: LRMII TRANSCEIVER MODULE
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 90 450.0  -  470.0 0.001 0.444  PM 8K12F1D
EF 90 450.0  -  470.0 0.001 0.444  PM 8K12F1W
EF 90 450.0  -  470.0 0.001 0.444  PM 8K12F1X
EF 90 450.0  -  470.0 0.01 0.444  PM 8K12F1D
EF 90 450.0  -  470.0 0.01 0.444  PM 8K12F1W
EF 90 450.0  -  470.0 0.01 0.444  PM 8K12F1X
EF 90 450.0  -  470.0 0.1 0.444  PM 8K12F1D
EF 90 450.0  -  470.0 0.1 0.444  PM 8K12F1W
EF 90 450.0  -  470.0 0.1 0.444  PM 8K12F1X

Single Modular Approval. Power listed is conducted. This device is to be used only for mobile and fixed applications. The maximum antenna gain for this device as reported to the FCC is 4.15dBi. The module antenna must be installed to meet the RF exposure compliance separation distance of 20 cm and any additional testing and authorization process as required. Co-location of this module with other transmitters that operate simultaneously is required to be evaluated using the FCC multi-transmitter procedures. OEM integrators and end-Users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations.

EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

EAS Grant - Application 6BgKNCMliY2PJrZ93jFXzQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Cattron North America Inc.
655 N. River Road NW Suite A
Warren, OH 44483-2254
United States
  Date of Grant: 04/16/2019

Application Dated: 04/16/2019
 
Attention: David Stagg , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CN289693
Name of Grantee:  Cattron North America Inc.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: LRMII TRANSCEIVER MODULE
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 90 450.0  -  470.0 0.001 0.444  PM 8K12F1D
EF 90 450.0  -  470.0 0.001 0.444  PM 8K12F1W
EF 90 450.0  -  470.0 0.001 0.444  PM 8K12F1X
EF 90 450.0  -  470.0 0.01 0.444  PM 8K12F1D
EF 90 450.0  -  470.0 0.01 0.444  PM 8K12F1W
EF 90 450.0  -  470.0 0.01 0.444  PM 8K12F1X
EF 90 450.0  -  470.0 0.1 0.444  PM 8K12F1D
EF 90 450.0  -  470.0 0.1 0.444  PM 8K12F1W
EF 90 450.0  -  470.0 0.1 0.444  PM 8K12F1X

Single Modular Approval. Power listed is conducted. This device is to be used only for mobile and fixed applications. The maximum antenna gain for this device as reported to the FCC is 4.15dBi. The module antenna must be installed to meet the RF exposure compliance separation distance of 20 cm and any additional testing and authorization process as required. Co-location of this module with other transmitters that operate simultaneously is required to be evaluated using the FCC multi-transmitter procedures. OEM integrators and end-Users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations.


EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

Mail To: