FCC ID COFWMNBM11

802.11bgn Wireless LAN Module

by Universal Global Scientific Industrial Co., Ltd.

Grantee Code: COF   Product Code: WMNBM11
Latest application date: 2013-06-24

FCC ID Device Details

FCC IDCOFWMNBM11
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeCOF
Product CodeWMNBM11
Applicant BusinessUniversal Global Scientific Industrial Co., Ltd. 🇹🇼
Related Domains ms.usi.com.tw
Equipment Class802.11bgn Wireless LAN Module
Test FirmBureau Veritas CPS (H.K.) Ltd., Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2013-06-24

Exhibits

DocumentTypeAvailableFile
User Manual.pdfUsers Manual2013-08-01PDF 1.2 MB
Internal Photos.pdfInternal Photos2013-08-01PDF 464.7 KB
External Photos.pdfExternal Photos2013-08-01PDF 784.9 KB
Label and Location.pdfID Label/Location Info2013-06-24PDF 165.4 KB
Operational Description.pdfOperational Description2013-06-24PDF 39.1 KB
Test Setup Photos.pdfTest Setup Photos2013-08-01PDF 421.1 KB
Test Report.pdfTest Report2013-06-24PDF 481.2 KB
Attestation (Channel and Mode Declaration).pdfAttestation Statements2013-06-24PDF 618.4 KB
Confidentiality Request (Shortterm).pdfCover Letter(s)2013-06-24PDF 598.8 KB
Confidentiality Request.pdfCover Letter(s)2013-06-24PDF 702.8 KB
Cover Letter (Agent Authorization).pdfCover Letter(s)2013-06-24PDF 1.2 MB
Cover Letter (Modular Approval Request).pdfCover Letter(s)2013-06-24PDF 18.4 KB
RF Exposure Info (MPE).pdfRF Exposure Info2013-06-24PDF 60.6 KB

Application Information

Application IDVG3YVqF5xjUgj+Oio7CoOw==
Final Action Date2013-06-24
Application PurposeOriginal Equipment
Applicant FRN0021670591
ModelWMNBM11
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device Description802.11bgn Wireless LAN Module
Responsible PartyMartin Shih, Manager, martins@ms.usi.com.tw , 886-49-235-0876
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch, richard.chen@tw.bureauveritas.com , 886-3-3183232
TCB Emailcertification@curtis-straus.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date08/01/2013
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. Single modular approval for mobile RF Exposure conditions. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Approval is limited to OEM installation only. OEM integrators and end users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter.

Applications

Application IDDatePurpose
VG3YVqF5xjUgj+Oio7CoOw==2013-06-24Original Equipment

Equipment Authorization

FrequencyOutputRules
2412-2462 MHz0.237000015C

Grants

TCB Grant - Application VG3YVqF5xjUgj+Oio7CoOw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Curtis-Straus LLC
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 06/24/2013

Application Dated: 06/24/2013
Universal Global Scientific Industrial Co., Ltd.
141, Lane 351, Sec.1, Taiping Road,
Tsaotuen
Nantou, 54261
Taiwan
 
Attention: Martin Shih , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  COFWMNBM11
Name of Grantee:  Universal Global Scientific Industrial Co., Ltd.
Equipment Class: Digital Transmission System
Notes: 802.11bgn Wireless LAN Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.237  

Output power listed is conducted. Single modular approval for mobile RF Exposure conditions. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Approval is limited to OEM installation only. OEM integrators and end users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter.

EAS Grant - Application VG3YVqF5xjUgj+Oio7CoOw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Universal Global Scientific Industrial Co., Ltd.
141, Lane 351, Sec.1, Taiping Road, TsaotuenP.O. Box ,
Nantou, 54261
Taiwan
  Date of Grant: 06/24/2013

Application Dated: 06/24/2013
 
Attention: Martin Shih , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  COFWMNBM11
Name of Grantee:  Universal Global Scientific Industrial Co., Ltd.
Equipment Class: Digital Transmission System
Notes: 802.11bgn Wireless LAN Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.237  

Output power listed is conducted. Single modular approval for mobile RF Exposure conditions. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Approval is limited to OEM installation only. OEM integrators and end users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter.



Mail To: