FCC ID CZO23LP35

LIFEPAK 35

by Physio-Control, Inc.

Grantee Code: CZO   Product Code: 23LP35
Latest application date: 2024-02-12

FCC ID Device Details

FCC IDCZO23LP35
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeCZO
Product Code23LP35
Applicant BusinessPhysio-Control, Inc. 🇺🇸
Related Domains stryker.com
Equipment ClassLIFEPAK 35
Test FirmSporton International Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzClass II permissive change or modification of presently authorized equipment2024-02-12
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2024-02-12
5745-5825 MHzClass II permissive change or modification of presently authorized equipment2024-02-12
2412-2462 MHzChange in identification of presently authorized equipment. Original FCC ID: Z64-WL18DBMOD Grant Date: 12/24/20142023-10-30
5180-5240 MHzChange in identification of presently authorized equipment. Original FCC ID: Z64-WL18DBMOD Grant Date: 12/24/20142023-10-30
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: Z64-WL18DBMOD Grant Date: 12/24/20142023-10-30

Exhibits

DocumentTypeAvailableFile
Modular Integration InstructionsUsers Manual2024-02-12PDF 3 MB
Modular Integration InstructionsUsers Manual2023-10-30PDF 327.2 KB
Internal PhotosInternal Photos2024-02-12PDF 117.1 KB
External PhotosExternal Photos2024-02-12PDF 68.8 KB
External PhotosExternal Photos2023-10-30PDF 43.5 KB
ID LabelID Label/Location Info2023-10-30PDF 108 KB
Test Setup PhotosTest Setup Photos2024-02-12PDF 471 KB
Attestation regarding Covered EquipmentAttestation Statements2024-02-12PDF 345 KB
Attestation regarding covered equipmentAttestation Statements2024-02-12PDF 345 KB
US Agent AttestationAttestation Statements2024-02-12PDF 438 KB
US agent attestationAttestation Statements2024-02-12PDF 438 KB
Cover letterCover Letter(s)2024-02-12PDF 276.7 KB
Cover LetterCover Letter(s)2023-10-30PDF 274.8 KB
Cover letterCover Letter(s)2023-10-30PDF 4 MB
SAR report part 1 of 6RF Exposure Info2024-02-12PDF 956.4 KB
SAR report part 1 of 7RF Exposure Info2024-02-12PDF 2.3 MB
SAR report part 2 of 6RF Exposure Info2024-02-12PDF 235 KB
SAR report part 2 of 7RF Exposure Info2024-02-12PDF 2.1 MB
SAR report part 3 of 6RF Exposure Info2024-02-12PDF 180.7 KB
SAR report part 3 of 7RF Exposure Info2024-02-12PDF 5 MB
SAR report part 4 of 6RF Exposure Info2024-02-12PDF 3.4 MB
SAR report part 4 of 7RF Exposure Info2024-02-12PDF 5 MB
SAR report part 5 of 6RF Exposure Info2024-02-12PDF 426.8 KB
SAR report part 5 of 7RF Exposure Info2024-02-12PDF 3.8 MB
SAR report part 6 of 6RF Exposure Info2024-02-12PDF 51 KB
SAR report part 6 of 7RF Exposure Info2024-02-12PDF 5.1 MB
SAR report part 7 of 7RF Exposure Info2024-02-12PDF 5.3 MB

Application Information

Application IDeojS3bb9alQ338iRpP/j3Q==
Final Action Date2024-02-12
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0021591144
Model23LP35
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionLIFEPAK 35
Responsible PartyTimothy Rand, Sr. Compliance Engineer, tim.rand@stryker.com , 425-867-4477
Test FirmAlex Chen, Sporton International Inc., alex@sporton.com.tw , 88633273456
TCB Emailbrian.fahey@element.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsSingle Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations. This device has a 20 and 40 MHz bandwidth mode. C2PC for portable use in LIFEPAK 35. The LIFEPAK 35 also contains a PCB standalone radio. The highest reported SAR for body exposure: NII 1.19 W/kg, DTS 0.43 W/kg.

Applications

Application IDDatePurpose
eojS3bb9alQ338iRpP/j3Q==2024-02-12Class II permissive change or modification of presently authorized equipment
8F5YzQ3hIVv2kZ65n+t4Fw==2024-02-12Class II permissive change or modification of presently authorized equipment
/dmNpbVvwS1w2lswy1lyTg==2024-02-12Class II permissive change or modification of presently authorized equipment
fGutk0Yt1HKfUwROlT/MGA==2023-10-30Change in identification of presently authorized equipment. Original FCC ID: Z64-WL18DBMOD Grant Date: 12/24/2014
G7MyH3O0J41jccZEszknxw==2023-10-30Change in identification of presently authorized equipment. Original FCC ID: Z64-WL18DBMOD Grant Date: 12/24/2014
D6czygVnLaAlm6VcS2qE4g==2023-10-30Change in identification of presently authorized equipment. Original FCC ID: Z64-WL18DBMOD Grant Date: 12/24/2014

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.014600015CCC
2402-2480 MHz0.004915CCC
2412-2462 MHz0.243215CCC, MO
5180-5240 MHz0.038215ECC
5190-5230 MHz0.049915ECC
5260-5320 MHz0.024415ECC, ND
5270-5310 MHz0.052515ECC, ND
5500-5700 MHz0.069815ECC, ND
5745-5825 MHz0.061415ECC

Grants

TCB Grant - Application G7MyH3O0J41jccZEszknxw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Element Materials Technology Portland - Evergreen
6775 NE Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 10/30/2023

Application Dated: 10/30/2023
Physio-Control, Inc.
11811 Willows Road NE
Redmond, WA 98052
 
Attention: Timothy Rand , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CZO23LP35
Name of Grantee:  Physio-Control, Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: LIFEPAK 35
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0382  
CC 15E 5190.0  -  5230.0 0.0499  
CC ND 15E 5260.0  -  5320.0 0.0244  
CC ND 15E 5270.0  -  5310.0 0.0525  
CC 15E 5745.0  -  5825.0 0.0614  
CC ND 15E 5500.0  -  5700.0 0.0698  

Single Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations. This device has a 20 and 40 MHz bandwidth mode.

CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application G7MyH3O0J41jccZEszknxw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Physio-Control, Inc.
11811 Willows Road NE
Redmond, WA 98052
United States
  Date of Grant: 10/30/2023

Application Dated: 10/30/2023
 
Attention: Timothy Rand , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CZO23LP35
Name of Grantee:  Physio-Control, Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: LIFEPAK 35
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0382  
CC 15E 5190.0  -  5230.0 0.0499  
CC ND 15E 5260.0  -  5320.0 0.0244  
CC ND 15E 5270.0  -  5310.0 0.0525  
CC 15E 5745.0  -  5825.0 0.0614  
CC ND 15E 5500.0  -  5700.0 0.0698  

Single Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations. This device has a 20 and 40 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application fGutk0Yt1HKfUwROlT/MGA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Element Materials Technology Portland - Evergreen
6775 NE Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 10/30/2023

Application Dated: 10/30/2023
Physio-Control, Inc.
11811 Willows Road NE
Redmond, WA 98052
 
Attention: Timothy Rand , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CZO23LP35
Name of Grantee:  Physio-Control, Inc.
Equipment Class: Digital Transmission System
Notes: LIFEPAK 35
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0049  
CC MO 15C 2412.0  -  2462.0 0.2432  

Single Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations. This device has a 20 and 40 MHz bandwidth mode.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application fGutk0Yt1HKfUwROlT/MGA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Physio-Control, Inc.
11811 Willows Road NE
Redmond, WA 98052
United States
  Date of Grant: 10/30/2023

Application Dated: 10/30/2023
 
Attention: Timothy Rand , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CZO23LP35
Name of Grantee:  Physio-Control, Inc.
Equipment Class: Digital Transmission System
Notes: LIFEPAK 35
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0049  
CC MO 15C 2412.0  -  2462.0 0.2432  

Single Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations. This device has a 20 and 40 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application eojS3bb9alQ338iRpP/j3Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Element Materials Technology Portland - Evergreen
6775 NE Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 02/12/2024

Application Dated: 02/12/2024
Physio-Control, Inc.
11811 Willows Road NE
Redmond, WA 98052
 
Attention: Timothy Rand , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CZO23LP35
Name of Grantee:  Physio-Control, Inc.
Equipment Class: Digital Transmission System
Notes: LIFEPAK 35
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0049  
CC MO 15C 2412.0  -  2462.0 0.2432  

Single Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations. This device has a 20 and 40 MHz bandwidth mode.

C2PC for portable use in LIFEPAK 35. The LIFEPAK 35 also contains a PCB standalone radio. The highest reported SAR for body exposure: NII 1.19 W/kg, DTS 0.43 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application eojS3bb9alQ338iRpP/j3Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Physio-Control, Inc.
11811 Willows Road NE
Redmond, WA 98052
United States
  Date of Grant: 02/12/2024

Application Dated: 02/12/2024
 
Attention: Timothy Rand , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CZO23LP35
Name of Grantee:  Physio-Control, Inc.
Equipment Class: Digital Transmission System
Notes: LIFEPAK 35
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0049  
CC MO 15C 2412.0  -  2462.0 0.2432  

Single Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations. This device has a 20 and 40 MHz bandwidth mode.

C2PC for portable use in LIFEPAK 35. The LIFEPAK 35 also contains a PCB standalone radio. The highest reported SAR for body exposure: NII 1.19 W/kg, DTS 0.43 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application D6czygVnLaAlm6VcS2qE4g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Element Materials Technology Portland - Evergreen
6775 NE Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 10/30/2023

Application Dated: 10/30/2023
Physio-Control, Inc.
11811 Willows Road NE
Redmond, WA 98052
 
Attention: Timothy Rand , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CZO23LP35
Name of Grantee:  Physio-Control, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: LIFEPAK 35
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0146  

Single Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application D6czygVnLaAlm6VcS2qE4g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Physio-Control, Inc.
11811 Willows Road NE
Redmond, WA 98052
United States
  Date of Grant: 10/30/2023

Application Dated: 10/30/2023
 
Attention: Timothy Rand , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CZO23LP35
Name of Grantee:  Physio-Control, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: LIFEPAK 35
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0146  

Single Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 8F5YzQ3hIVv2kZ65n+t4Fw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Element Materials Technology Portland - Evergreen
6775 NE Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 02/12/2024

Application Dated: 02/12/2024
Physio-Control, Inc.
11811 Willows Road NE
Redmond, WA 98052
 
Attention: Timothy Rand , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CZO23LP35
Name of Grantee:  Physio-Control, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: LIFEPAK 35
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0146  

Single Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations.

C2PC for portable use in LIFEPAK 35. The LIFEPAK 35 also contains a PCB standalone radio. The highest reported SAR for body exposure: NII 1.19 W/kg, DTS 0.43 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 8F5YzQ3hIVv2kZ65n+t4Fw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Physio-Control, Inc.
11811 Willows Road NE
Redmond, WA 98052
United States
  Date of Grant: 02/12/2024

Application Dated: 02/12/2024
 
Attention: Timothy Rand , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CZO23LP35
Name of Grantee:  Physio-Control, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: LIFEPAK 35
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0146  

Single Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations.

C2PC for portable use in LIFEPAK 35. The LIFEPAK 35 also contains a PCB standalone radio. The highest reported SAR for body exposure: NII 1.19 W/kg, DTS 0.43 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application /dmNpbVvwS1w2lswy1lyTg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Element Materials Technology Portland - Evergreen
6775 NE Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 02/12/2024

Application Dated: 02/12/2024
Physio-Control, Inc.
11811 Willows Road NE
Redmond, WA 98052
 
Attention: Timothy Rand , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CZO23LP35
Name of Grantee:  Physio-Control, Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: LIFEPAK 35
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0382  
CC 15E 5190.0  -  5230.0 0.0499  
CC ND 15E 5260.0  -  5320.0 0.0244  
CC ND 15E 5270.0  -  5310.0 0.0525  
CC 15E 5745.0  -  5825.0 0.0614  
CC ND 15E 5500.0  -  5700.0 0.0698  

Single Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations. This device has a 20 and 40 MHz bandwidth mode.

C2PC for portable use in LIFEPAK 35. The LIFEPAK 35 also contains PCB standalone radio. The highest reported SAR for body exposure: NII 1.19 W/kg, DTS 0.43 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application /dmNpbVvwS1w2lswy1lyTg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Physio-Control, Inc.
11811 Willows Road NE
Redmond, WA 98052
United States
  Date of Grant: 02/12/2024

Application Dated: 02/12/2024
 
Attention: Timothy Rand , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  CZO23LP35
Name of Grantee:  Physio-Control, Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: LIFEPAK 35
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0382  
CC 15E 5190.0  -  5230.0 0.0499  
CC ND 15E 5260.0  -  5320.0 0.0244  
CC ND 15E 5270.0  -  5310.0 0.0525  
CC 15E 5745.0  -  5825.0 0.0614  
CC ND 15E 5500.0  -  5700.0 0.0698  

Single Modular Approval. Power listed is conducted. Approval is limited to OEM installation only. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations. This device has a 20 and 40 MHz bandwidth mode.

C2PC for portable use in LIFEPAK 35. The LIFEPAK 35 also contains PCB standalone radio. The highest reported SAR for body exposure: NII 1.19 W/kg, DTS 0.43 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

Mail To: