FCC ID D6XAG300PLUS
Gateway
by Tecom Co Ltd
Grantee Code: D6X Product Code: AG300PLUS
Latest application date: 2018-10-16
FCC ID Device Details
| FCC ID | D6XAG300PLUS |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | D6X |
| Product Code | AG300PLUS |
| Applicant Business | Tecom Co Ltd 🇹🇼 |
| Related Domains | |
| Equipment Class | Gateway |
| Test Firm | MRT Technology (Taiwan) Co.,Ltd |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2018-10-16 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2019-04-14 | PDF 5.4 MB |
| Internal Photo | Internal Photos | 2019-04-14 | PDF 818.2 KB |
| External Photo | External Photos | 2019-04-14 | PDF 661.8 KB |
| Label and Location | ID Label/Location Info | 2018-10-16 | PDF 108 KB |
| Setup Photo | Test Setup Photos | 2019-04-14 | PDF 532.4 KB |
| Test Report | Test Report | 2018-10-16 | PDF 5.6 MB |
| LTCR letter | Cover Letter(s) | 2018-10-16 | PDF 67.7 KB |
| POA | Cover Letter(s) | 2018-10-16 | PDF 57.8 KB |
| STCR letter | Cover Letter(s) | 2018-10-16 | PDF 103.8 KB |
| RF exposure information | RF Exposure Info | 2018-10-16 | PDF 152.9 KB |
| Block Diagram Metadata only | Block Diagram | PDF 22.5 KB | |
| Schematic Diagram Metadata only | Schematics | PDF 412.9 KB | |
| Operational Description Metadata only | Operational Description | PDF 521.9 KB |
Application Information
| Application ID | zGRbQBmkCbA6wt+2USyfaw== |
|---|---|
| Final Action Date | 2018-10-16 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0006258099 |
| Model | AG300PLUS |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Gateway |
| Responsible Party | Sheng Yih Lin, Deputy Project Manager, sylin@tecom.com.tw |
| Test Firm | Chenz Ker, MRT Technology (Taiwan) Co.,Ltd, chenzker@mrt-cert.com |
| TCB Email | stuart.beck@nemko.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 04/14/2019 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. This device has 20MHz and 40 MHz bandwidth modes. The RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this filing complies with KDB 447498 and is approved for mobile/fixed operation. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| zGRbQBmkCbA6wt+2USyfaw== | 2018-10-16 | Original Equipment |
Grants
TCB Grant - Application zGRbQBmkCbA6wt+2USyfaw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 10/16/2018 Application Dated: 10/16/2018 |
| Tecom Co Ltd |
| 23, R&D Road 2 |
| Science Based Ind Park |
| Hsin-Chu, Taiwan |
| Attention: Sheng Yih Lin , Deputy Project Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | D6XAG300PLUS |
| Name of Grantee: | Tecom Co Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Gateway |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 15C | 2412.0 - 2462.0 | 0.258 |
| Output power listed is conducted. This device has 20MHz and 40 MHz bandwidth modes. The RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this filing complies with KDB 447498 and is approved for mobile/fixed operation. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application zGRbQBmkCbA6wt+2USyfaw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Tecom Co Ltd 23, R&D Road 2 Science Based Ind Park Hsin-Chu, Taiwan |
Date of Grant: 10/16/2018 Application Dated: 10/16/2018 |
| Attention: Sheng Yih Lin , Deputy Project Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | D6XAG300PLUS |
| Name of Grantee: | Tecom Co Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Gateway |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 15C | 2412.0 - 2462.0 | 0.258 |
| Output power listed is conducted. This device has 20MHz and 40 MHz bandwidth modes. The RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits - this filing complies with KDB 447498 and is approved for mobile/fixed operation. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |