FCC ID DV8DSX1

DS-X Series ECG, Respiration and SpO2 Transmitter

by Fukuda Denshi Co Ltd

Grantee Code: DV8   Product Code: DSX1
Latest application date: 2026-01-15

FCC ID Device Details

FCC IDDV8DSX1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeDV8
Product CodeDSX1
Applicant BusinessFukuda Denshi Co Ltd 🇯🇵
Related Domains fukuda.co.jp fukudaamerica.com
Equipment ClassDS-X Series ECG, Respiration and SpO2 Transmitter
Test FirmSGS Taiwan Ltd. Central RF Lab

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2422-2452 MHzClass II permissive change or modification of presently authorized equipment2026-01-15
5745-5825 MHzClass II permissive change or modification of presently authorized equipment2026-01-15
5745-5825 MHzChange in identification of presently authorized equipment. Original FCC ID: XPYJODYW263 Grant Date: 04/28/20212025-12-01
2422-2452 MHzChange in identification of presently authorized equipment. Original FCC ID: XPYJODYW263 Grant Date: 04/28/20212025-12-01
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: XPYJODYW263 Grant Date: 04/28/20212025-12-01

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2026-01-15PDF 1.9 MB
Installation InstructionsUsers Manual2025-12-01PDF 1.5 MB
Internal PhotosInternal Photos2026-01-15PDF 3.3 MB
External PhotosExternal Photos2026-01-15PDF 673.7 KB
External PhotosExternal Photos2025-12-01PDF 138.9 KB
Label Info & LocationID Label/Location Info2026-01-15PDF 521.7 KB
Label Info and LocationID Label/Location Info2025-12-01PDF 207.5 KB
TsupTest Setup Photos2026-01-15PDF 562.3 KB
Tsup SAR App ATest Setup Photos2026-01-15PDF 901.6 KB
Antenna ReportTest Report2026-01-15PDF 1.7 MB
Test Report 15.247 BLETest Report2026-01-15PDF 1.8 MB
Test Report 15.247 WLAN 2.4GHzTest Report2026-01-15PDF 3.8 MB
Test Report 15.407 WLAN 5GHzTest Report2026-01-15PDF 3.1 MB
Attestation Statement part 2.911(d)(7)Attestation Statements2026-01-15PDF 484.2 KB
Attstn Stmts parts 2.911(d)(5)(i)&(ii)Attestation Statements2026-01-15PDF 540.4 KB
Att Statements 2.911(d)(5)(7)Attestation Statements2025-12-01PDF 484.2 KB
Att Statements 2.911(d)(5)(i)&(ii)Attestation Statements2025-12-01PDF 540.4 KB
Agent AuthorizationCover Letter(s)2026-01-15PDF 48.8 KB
C2PCCover Letter(s)2026-01-15PDF 147 KB
Authorization LetterCover Letter(s)2025-12-01PDF 48.3 KB
Change in ID - New ApplicantCover Letter(s)2025-12-01PDF 397.8 KB
Change in ID - Original ApplicantCover Letter(s)2025-12-01PDF 67.1 KB
SAR App B DAE & Probe Cal -1RF Exposure Info2026-01-15PDF 5.3 MB
SAR App B DAE & Probe Cal -2RF Exposure Info2026-01-15PDF 2.3 MB
SAR App C Phantom & Dipole CalRF Exposure Info2026-01-15PDF 2.5 MB
SAR App C Phantom Desc & Dipole CalRF Exposure Info2026-01-15PDF 2.5 MB
SAR App D Dipole Extended CalRF Exposure Info2026-01-15PDF 713.5 KB
SAR ReportRF Exposure Info2026-01-15PDF 2.4 MB

Application Information

Application IDQ6c1E3HolQMHPuGHaQ8aFg==
Final Action Date2026-01-15
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0007498769
ModelDSX1
Frequency Range2422-2452 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionDS-X Series ECG, Respiration and SpO2 Transmitter
Responsible PartyTakashi Nomura, takashi.nomura@fukuda.co.jp , 81-3-5684-1540
Non-Technical ContactDouglas W Blakely, Fukuda Denshi USA, Inc., dblakely@fukudaamerica.com , +1 (210) 240-4521
Test FirmRyan WANG, SGS Taiwan Ltd. Central RF Lab, ryan-ec.wang@sgs.com , 886222993279
TCB Emailtei@timcoengr.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
Q6c1E3HolQMHPuGHaQ8aFg==2026-01-15Class II permissive change or modification of presently authorized equipment
0IpZu9/y6MdT1IiD+aXq9Q==2026-01-15Class II permissive change or modification of presently authorized equipment
V2VzgXHLLFu6fbpaCiSv4g==2025-12-01Change in identification of presently authorized equipment. Original FCC ID: XPYJODYW263 Grant Date: 04/28/2021
IXh4xMlA3nDo6On6KUdJug==2025-12-01Change in identification of presently authorized equipment. Original FCC ID: XPYJODYW263 Grant Date: 04/28/2021
3vEKFNXO1le/8n7whMj/kQ==2025-12-01Change in identification of presently authorized equipment. Original FCC ID: XPYJODYW263 Grant Date: 04/28/2021

Equipment Authorization

FrequencyOutputRulesGrant Notes
5180-5240 MHz0.02615ECC
5260-5320 MHz0.02715ECC
5500-5720 MHz0.02515ECC
5745-5825 MHz0.03215ECC
2402-2480 MHz0.002515CCC
2412-2462 MHz0.03715CCC
2422-2452 MHz0.01215CCC
2402-2480 MHz0.01215CCC

Grants

TCB Grant - Application V2VzgXHLLFu6fbpaCiSv4g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 12/01/2025

Application Dated: 11/21/2025
Fukuda Denshi Co Ltd
3-39-4 Hongo Bunkyo-Ku
Tokyo, 113-8483
Japan
 
Attention: Takashi Nomura , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  DV8DSX1
Name of Grantee:  Fukuda Denshi Co Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Host-based module with Wi-Fi and Bluetooth 5.0
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.026  
CC 15E 5260.0  -  5320.0 0.027  
CC 15E 5500.0  -  5720.0 0.025  
CC 15E 5745.0  -  5825.0 0.032  

Power output listed is conducted. Single modular approval. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures and RF exposure compliance. This filing meets the KDB publication 447498 requirements for mobile RF exposure conditions. The Grantee is responsible for providing the documentation required for modular use. The module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. The responsibility for the use of this module, in all configurations used or contemplated, remains with the Grantee. This device has 20 MHz, 40 MHz and 80 MHz bandwidth modes. This device also contains Bluetooth, BLE and 2.4 GHz WLAN transmitters.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application Q6c1E3HolQMHPuGHaQ8aFg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 01/15/2026

Application Dated: 01/09/2026
Fukuda Denshi Co Ltd
3-39-4 Hongo Bunkyo-Ku
Tokyo, 113-8483
Japan
 
Attention: Takashi Nomura , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  DV8DSX1
Name of Grantee:  Fukuda Denshi Co Ltd
Equipment Class: Digital Transmission System
Notes: DS-X Series ECG, Respiration and SpO2 Transmitter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0025  
CC 15C 2412.0  -  2462.0 0.037  
CC 15C 2422.0  -  2452.0 0.012  

Power output listed is conducted. Single modular approval. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures and RF exposure compliance. This filing meets the KDB publication 447498 requirements for mobile RF exposure conditions. The Grantee is responsible for providing the documentation required for modular use. The module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. The responsibility for the use of this module, in all configurations used or contemplated, remains with the Grantee. This device has 20 MHz and 40 MHz bandwidth modes. This device also contains Bluetooth and U-NII transmitters.

Class II Permissive Change: Authorizes the integration of this device into the Fukuda Denshi DS-X Series ECG, Respiration and SpO2 Transmitter, Models DS-X1F, DS-X1M and DS-X1N. The highest reported SAR for body, simultaneous transmission and product-specific (10g extremity SAR) exposure conditions are 0.61 W/kg, 0.67 W/kg and 0.26 W/kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application IXh4xMlA3nDo6On6KUdJug==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 12/01/2025

Application Dated: 11/21/2025
Fukuda Denshi Co Ltd
3-39-4 Hongo Bunkyo-Ku
Tokyo, 113-8483
Japan
 
Attention: Takashi Nomura , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  DV8DSX1
Name of Grantee:  Fukuda Denshi Co Ltd
Equipment Class: Digital Transmission System
Notes: Host-based module with Wi-Fi and Bluetooth 5.0
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0025  
CC 15C 2412.0  -  2462.0 0.037  
CC 15C 2422.0  -  2452.0 0.012  

Power output listed is conducted. Single modular approval. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures and RF exposure compliance. This filing meets the KDB publication 447498 requirements for mobile RF exposure conditions. The Grantee is responsible for providing the documentation required for modular use. The module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. The responsibility for the use of this module, in all configurations used or contemplated, remains with the Grantee. This device has 20 MHz and 40 MHz bandwidth modes. This device also contains Bluetooth and U-NII transmitters.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 3vEKFNXO1le/8n7whMj/kQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 12/01/2025

Application Dated: 11/21/2025
Fukuda Denshi Co Ltd
3-39-4 Hongo Bunkyo-Ku
Tokyo, 113-8483
Japan
 
Attention: Takashi Nomura , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  DV8DSX1
Name of Grantee:  Fukuda Denshi Co Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Host-based module with Wi-Fi and Bluetooth 5.0
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.012  

Power output listed is conducted. Single modular approval The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures and RF exposure compliance. This filing meets the KDB publication 447498 requirements for mobile RF exposure conditions. The Grantee is responsible for providing the documentation required for modular use. The module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. The responsibility for the use of this module, in all configurations used or contemplated, remains with the Grantee. This device also contains BLE, 2.4 GHz WLAN and U-NII transmitters.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 0IpZu9/y6MdT1IiD+aXq9Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 01/15/2026

Application Dated: 01/09/2026
Fukuda Denshi Co Ltd
3-39-4 Hongo Bunkyo-Ku
Tokyo, 113-8483
Japan
 
Attention: Takashi Nomura , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  DV8DSX1
Name of Grantee:  Fukuda Denshi Co Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: DS-X Series ECG, Respiration and SpO2 Transmitter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.026  
CC 15E 5260.0  -  5320.0 0.027  
CC 15E 5500.0  -  5720.0 0.025  
CC 15E 5745.0  -  5825.0 0.032  

Power output listed is conducted. Single modular approval. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures and RF exposure compliance. This filing meets the KDB publication 447498 requirements for mobile RF exposure conditions. The Grantee is responsible for providing the documentation required for modular use. The module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. The responsibility for the use of this module, in all configurations used or contemplated, remains with the Grantee. This device has 20 MHz, 40 MHz and 80 MHz bandwidth modes. This device also contains Bluetooth, BLE and 2.4 GHz WLAN transmitters.

Class II Permissive Change: Authorizes the integration of this device into the Fukuda Denshi DS-X Series ECG, Respiration and SpO2 Transmitter, Models DS-X1F, DS-X1M and DS-X1N. The highest reported SAR for body, simultaneous transmission and product-specific (10g extremity SAR) exposure conditions are 1.02 W/kg, 1.08 W/kg and 0.33 W/kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.