FCC ID E5MDS-MERCODU5

Wimax Industrial Radio

by GE MDS LLC

Grantee Code: E5M   Product Code: DSMERCODU5
Latest application date: 2012-01-17

FCC ID Device Details

FCC IDE5MDS-MERCODU5
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeE5M
Product CodeDSMERCODU5
Applicant BusinessGE MDS LLC 🇺🇸
Related Domains ge.com
Equipment ClassWimax Industrial Radio
Test FirmNational Technical Systems - Silicon Valley

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5727-5847 MHzOriginal Equipment2012-01-17

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2012-01-17PDF 1.9 MB
Internal PhotosInternal Photos2012-01-17PDF 1.6 MB
External PhotosExternal Photos2012-01-17PDF 355.5 KB
Label and LocationID Label/Location Info2012-01-17PDF 249 KB
Test Setup PhotosTest Setup Photos2012-01-17PDF 662.6 KB
Test ReportTest Report2012-01-17PDF 525.7 KB
Attestation StatementAttestation Statements2012-01-17PDF 55.1 KB
Authorization LetterCover Letter(s)2012-01-17PDF 27.1 KB
Confidentiality LetterCover Letter(s)2012-01-17PDF 22.7 KB
RF Exposure Info MPERF Exposure Info2012-01-17PDF 57.7 KB

Application Information

Application IDz2Auii5QsCeJDEetb8aK1A==
Final Action Date2012-01-17
Application PurposeOriginal Equipment
Applicant FRN0016050429
ModelDS-MERCODU5
Frequency Range5727-5847 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWimax Industrial Radio
Responsible PartyDennis W McCarthy, Agency Compliance Engineer, Dennis.Mccarthy2@ge.com , 585-242-8440
Technical ContactDennis McCarthy, GE MDS LLC, Dennis.McCarthy2@GE.com , 585-242-8440
Test FirmDavid Bare, National Technical Systems - Silicon Valley, david.bare@nts.com , 510-578-3500
TCB Emailhotline@acbcert.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower out is conducted at the antenna terminal. The antenna(s) used for this transmitter must be installed to provide a minimum separation distance from all persons as specified in the filing and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for 5 GHz band operations as described in this filing. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
z2Auii5QsCeJDEetb8aK1A==2012-01-17Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
5727-5847 MHz0.063000015CMO

Grants

TCB Grant - Application z2Auii5QsCeJDEetb8aK1A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 01/17/2012

Application Dated: 01/17/2012
GE MDS LLC
175 Science Parkway
Rochester, NY 14620-4261
 
Attention: Dennis McCarthy , Agency Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  E5MDS-MERCODU5
Name of Grantee:  GE MDS LLC
Equipment Class: Digital Transmission System
Notes: Wimax Industrial Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 5727.0  -  5847.0 0.063  

Power out is conducted at the antenna terminal. The antenna(s) used for this transmitter must be installed to provide a minimum separation distance from all persons as specified in the filing and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for 5 GHz band operations as described in this filing. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application z2Auii5QsCeJDEetb8aK1A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

GE MDS LLC
175 Science Parkway
Rochester, NY 14620-4261
United States
  Date of Grant: 01/17/2012

Application Dated: 01/17/2012
 
Attention: Dennis McCarthy , Agency Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  E5MDS-MERCODU5
Name of Grantee:  GE MDS LLC
Equipment Class: Digital Transmission System
Notes: Wimax Industrial Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 5727.0  -  5847.0 0.063  

Power out is conducted at the antenna terminal. The antenna(s) used for this transmitter must be installed to provide a minimum separation distance from all persons as specified in the filing and must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for 5 GHz band operations as described in this filing. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.