FCC ID E5MDS-OCR220

220MHz Data Transceiver Module for use in the Wabtec Operator Control Unit (OCU)

by GE MDS, LLC

Grantee Code: E5M   Product Code: DSOCR220
Latest application date: 2023-12-13

FCC ID Device Details

FCC IDE5MDS-OCR220
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeE5M
Product CodeDSOCR220
Applicant BusinessGE MDS, LLC 🇺🇸
Related Domains ge.com
Equipment Class220MHz Data Transceiver Module for use in the Wabtec Operator Control Unit (OCU)
Test FirmMiCOM Labs

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
220-222 MHzOriginal Equipment2023-12-13

Exhibits

DocumentTypeAvailableFile
Host Integration instructionUsers Manual2024-01-27PDF 3.6 MB
OCR220 Module Integration GuideUsers Manual2024-01-27PDF 616 KB
Internal photoInternal Photos2024-01-27PDF 987.1 KB
External photo_1External Photos2024-01-27PDF 763.2 KB
External photo_2External Photos2024-01-27PDF 28.1 KB
External photo_3External Photos2024-01-27PDF 27 KB
External photo_4External Photos2024-01-27PDF 575.1 KB
External photo_5External Photos2024-01-27PDF 701.6 KB
Label and locationID Label/Location Info2023-12-13PDF 92.1 KB
labelID Label/Location Info2023-12-13PDF 220.9 KB
Test setup photoTest Setup Photos2024-01-27PDF 384.9 KB
OCR220 FCC Part 90 test reportTest Report2023-12-13PDF 2 MB
Certification ApplicantAttestation Statements2023-12-13PDF 192.9 KB
Certification Equipment TypeAttestation Statements2023-12-13PDF 202.8 KB
US agent for service of processAttestation Statements2023-12-13PDF 165.1 KB
Agent AuthorizationCover Letter(s)2023-12-13PDF 128.2 KB
Confidentiality Request letterCover Letter(s)2023-12-13PDF 161.5 KB
FCC Modular Approval RequestCover Letter(s)2023-12-13PDF 42.8 KB
RF Exposure reportRF Exposure Info2023-12-13PDF 261.1 KB
Block diagram Metadata onlyBlock DiagramPDF 459.7 KB
Schematic_1 Metadata onlySchematicsPDF 3 MB
Schematic_2 Metadata onlySchematicsPDF 1.7 MB
Operational descriptions Metadata onlyOperational DescriptionPDF 957.8 KB
BOM_1 Metadata onlyParts List/Tune Up InfoPDF 534.8 KB
BOM_2 Metadata onlyParts List/Tune Up InfoPDF 543.4 KB

Application Information

Application IDUMB+Gk14RXN+VjWkzkDndA==
Final Action Date2023-12-13
Application PurposeOriginal Equipment
Applicant FRN0033030735
ModelDS-OCR220
Frequency Range220-222 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device Description220MHz Data Transceiver Module for use in the Wabtec Operator Control Unit (OCU)
Responsible PartyJohn Barenys, Senior Operations Manager, john.barenys@ge.com , 585-683-4254
Technical ContactGE MDS, LLC, john.barenys@ge.com
Test FirmGordon Hurst, MiCOM Labs, gordon_hurst@micomlabs.com , 925-462-0304
TCB Emailcertification@micomlabs.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date01/27/2024
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentLimited Single Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsLimited Modular Approval. Output power listed is conducted power. OEM integrators must be provided with antenna installation instructions. The OEM integrators must be instructed to ensure that the end user has no manual instructions to remove or install the device. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 36 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
UMB+Gk14RXN+VjWkzkDndA==2023-12-13Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
217.013-219.988 MHz1.96340.81ppm6K57G1D90.259
220-222 MHz1.98151.08ppm6K57G1D90T

Grants

TCB Grant - Application UMB+Gk14RXN+VjWkzkDndA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 12/13/2023

Application Dated: 11/13/2023
GE MDS, LLC
175 Science Parkway
Rochester, NY 14620-4261
 
Attention: John Barenys , Senior Operations Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  E5MDS-OCR220
Name of Grantee:  GE MDS, LLC
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: 220MHz Data Transceiver Module for use in the Wabtec Operator Control Unit (OCU)
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.259 217.0125  -  219.9875 1.9634 0.81  PM 6K57G1D
90T 220.0  -  222.0 1.9815 1.08  PM 6K57G1D

Limited Modular Approval. Output power listed is conducted power. OEM integrators must be provided with antenna installation instructions. The OEM integrators must be instructed to ensure that the end user has no manual instructions to remove or install the device. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 36 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

EAS Grant - Application UMB+Gk14RXN+VjWkzkDndA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

GE MDS, LLC
175 Science Parkway
Rochester, NY 14620-4261
United States
  Date of Grant: 12/13/2023

Application Dated: 11/13/2023
 
Attention: John Barenys , Senior Operations Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  E5MDS-OCR220
Name of Grantee:  GE MDS, LLC
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: 220MHz Data Transceiver Module for use in the Wabtec Operator Control Unit (OCU)
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.259 217.0125  -  219.9875 1.9634 0.81  PM 6K57G1D
90T 220.0  -  222.0 1.9815 1.08  PM 6K57G1D

Limited Modular Approval. Output power listed is conducted power. OEM integrators must be provided with antenna installation instructions. The OEM integrators must be instructed to ensure that the end user has no manual instructions to remove or install the device. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 36 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.



Mail To: