FCC ID E5MDS-SERIES4

MDS Four.9 Series Digital Radio System

by GE MDS, LLC

Grantee Code: E5M   Product Code: DSSERIES4
Latest application date: 2006-08-06

FCC ID Device Details

FCC IDE5MDS-SERIES4
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeE5M
Product CodeDSSERIES4
Applicant BusinessGE MDS, LLC 🇺🇸
Related Domains ge.com
Equipment ClassMDS Four.9 Series Digital Radio System
Test FirmElliott Laboratories Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
4940-4990 MHzOriginal Equipment2006-08-06

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2006-08-06PDF 1.5 MB
int photosInternal Photos2006-08-06PDF 239.5 KB
ext photosExternal Photos2006-08-06PDF 157.5 KB
label dwgID Label/Location Info2006-08-06PDF 52.6 KB
label locID Label/Location Info2006-08-06PDF 121.3 KB
test setup photosTest Setup Photos2006-08-06PDF 707.1 KB
test reportTest Report2006-08-06PDF 952.1 KB
Resp to TCBAttestation Statements2006-08-06PDF 139 KB
Conf reqCover Letter(s)2006-08-06PDF 52.2 KB
MPE EsatRF Exposure Info2006-08-06PDF 18 KB
Block Diagram Metadata onlyBlock DiagramPDF 43.9 KB
Schematic Metadata onlySchematicsPDF 799.6 KB
Op Desc Metadata onlyOperational DescriptionPDF 89 KB
Op Desc Inc Tune Up Info Metadata onlyParts List/Tune Up InfoPDF 89 KB

Application Information

Application IDQHo4JJGbfVDyM0h7AxhBuA==
Final Action Date2006-08-06
Application PurposeOriginal Equipment
Applicant FRN0016050429
ModelDS-SERIES4
Frequency Range4940-4990 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionMDS Four.9 Series Digital Radio System
Responsible PartyJustin Smith, Principal Engineer, Justin.Smith3@ge.com , 585-472-1715
Technical ContactJuan Martinez, Elliott Labortories, doc@elliottlabs.com , 408 245 7800
Test FirmDavid Bare, Elliott Laboratories Inc., dbare@elliottlabs.com , 408-245-7800
TCB Emailhotline@atcb.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is conducted. Occupational/Controlled MPE evaluation covers fixed-mounted and mobile operation at the power levels and antenna gains outlined in this filing. The antenna must be installed to provide an appropriate separation distance, outlined in the MPE exhibit in this filing) from all bystanders and it to be installed only in controlled environments. All installers of this device must receive training to have knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled exposure limit. Installers should receive training information for meeting Occupational Exposure Requirements, and must be provided with the training information. Installers and end-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
QHo4JJGbfVDyM0h7AxhBuA==2006-08-06Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
4940-4990 MHz0.20410000.4000000000ppm13M7X1D90

Grants

TCB Grant - Application QHo4JJGbfVDyM0h7AxhBuA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 08/06/2006

Application Dated: 08/06/2006
GE MDS, LLC
175 Science Parkway
Rochester, NY 14620-4261
 
Attention: Justin Smith , Principal Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  E5MDS-SERIES4
Name of Grantee:  GE MDS, LLC
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: MDS Four.9 Series Digital Radio System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 4940.0  -  4990.0 0.2041 0.4  PM 13M7X1D

Power Output listed is conducted. Occupational/Controlled MPE evaluation covers fixed-mounted and mobile operation at the power levels and antenna gains outlined in this filing. The antenna must be installed to provide an appropriate separation distance, outlined in the MPE exhibit in this filing) from all bystanders and it to be installed only in controlled environments. All installers of this device must receive training to have knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled exposure limit. Installers should receive training information for meeting Occupational Exposure Requirements, and must be provided with the training information. Installers and end-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application QHo4JJGbfVDyM0h7AxhBuA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

GE MDS, LLC
175 Science Parkway
Rochester, NY 14620-4261
United States
  Date of Grant: 08/06/2006

Application Dated: 08/06/2006
 
Attention: Justin Smith , Principal Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  E5MDS-SERIES4
Name of Grantee:  GE MDS, LLC
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: MDS Four.9 Series Digital Radio System
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 4940.0  -  4990.0 0.2041 0.4  PM 13M7X1D

Power Output listed is conducted. Occupational/Controlled MPE evaluation covers fixed-mounted and mobile operation at the power levels and antenna gains outlined in this filing. The antenna must be installed to provide an appropriate separation distance, outlined in the MPE exhibit in this filing) from all bystanders and it to be installed only in controlled environments. All installers of this device must receive training to have knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled exposure limit. Installers should receive training information for meeting Occupational Exposure Requirements, and must be provided with the training information. Installers and end-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: