FCC ID EHA-1000CP01SX1

1000CP01S, 1000CP02S, 1001CP01S

by Intermec Technologies Corporation

Grantee Code: EHA   Product Code: 1000CP01SX1
Latest application date: 2016-06-15

FCC ID Device Details

FCC IDEHA-1000CP01SX1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeEHA
Product Code1000CP01SX1
Applicant BusinessIntermec Technologies Corporation 🇺🇸
Related Domains honeywell.com
Equipment Class1000CP01S, 1000CP02S, 1001CP01S
Test FirmElement Materials Technology Seattle

Hearing Aid Compatibility

Handset MakerIntermec
Model NameCN70 Flexible Netwrk
Air Interface TechnologiesGSM, CDMA, WCDMA, WCDMA, GSM, CDMA, WCDMA
Operating Frequency Bands850, 850, 850, 1700, 1900, 1900, 1900
M-RatingN/A
M-Rating Certification DateN/A
M-Rating ANSI VersionN/A
T-RatingN/A
T-Rating Certification DateN/A
T-Rating ANSI VersionN/A
RemarksCN70 Flexible Network

Source: FCC archived Device Manufacturer Summary Report (2013).

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2016-06-15
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2016-06-15
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2015-05-13
824.2-848.8 MHzClass II permissive change or modification of presently authorized equipment2015-05-13
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2015-05-13
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2012-02-21
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2012-02-21
824.2-848.8 MHzClass II permissive change or modification of presently authorized equipment2012-02-21
824.2-848.8 MHzClass II permissive change or modification of presently authorized equipment2011-09-15
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2011-09-15
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2011-09-15
2402-2480 MHzOriginal Equipment2011-08-29
824.2-848.8 MHzOriginal Equipment2011-08-29
5180-5240 MHzOriginal Equipment2011-08-29

Exhibits

DocumentTypeAvailableFile
Compliance InsertUsers Manual2012-02-21PDF 340.7 KB
Quick Start GuideUsers Manual2012-02-21PDF 895.4 KB
Compliance Insert 1000CP01SUsers Manual2011-12-01PDF 471.6 KB
Compliance Insert 1000CP02SUsers Manual2011-12-01PDF 471.6 KB
Compliance Insert 1001CP01SUsers Manual2011-12-01PDF 478.8 KB
QSG 1000CP01SUsers Manual2011-12-01PDF 1.9 MB
QSG 1000CP02SUsers Manual2011-12-01PDF 1.5 MB
QSG 1001CP01SUsers Manual2011-12-01PDF 1.8 MB
User Manual part 1 of 2Users Manual2011-12-01PDF 4.7 MB
User Manual part 2 of 2Users Manual2011-12-01PDF 1.5 MB
Internal photosInternal Photos2015-05-13PDF 4.7 MB
Internal PhotosInternal Photos2012-02-21PDF 2.1 MB
Internal Photos 1000CP01SInternal Photos2011-12-01PDF 1.6 MB
Internal Photos 1000CP01SInternal Photos2011-12-01PDF 1.5 MB
Internal Photos 1000CP02SInternal Photos2011-12-01PDF 1.9 MB
Internal Photos 1000CP02SInternal Photos2011-12-01PDF 2 MB
Internal Photos 1001CP01SInternal Photos2011-12-01PDF 1.5 MB
Internal Photos 1001CP01SInternal Photos2011-12-01PDF 1.6 MB
External PhotosExternal Photos2015-05-13PDF 3.4 MB
External photosExternal Photos2015-05-13PDF 605.7 KB
External PhotosExternal Photos2012-02-21PDF 3.1 MB
External Photos 1000CP01SExternal Photos2011-12-01PDF 3.6 MB
External Photos 1000CP02SExternal Photos2011-12-01PDF 1.8 MB
External Photos 1001CP01SExternal Photos2011-12-01PDF 3.1 MB
ID LabelID Label/Location Info2012-02-21PDF 403.1 KB
ID Label 1000CP01SID Label/Location Info2011-09-15PDF 244.3 KB
ID Label 1000CP02SID Label/Location Info2011-09-15PDF 193.6 KB
ID Label 1001CP01SID Label/Location Info2011-09-15PDF 186 KB
Antenna Info RC12Operational Description2011-08-29PDF 5.4 MB
Antenna Info 1 MC8355Operational Description2011-08-29PDF 5.3 MB
Antenna Info 2 MC8355Operational Description2011-08-29PDF 5.4 MB
Test Setup PhotosTest Setup Photos2016-06-15PDF 912.7 KB
Test setup PhotosTest Setup Photos2015-05-13PDF 724.3 KB
Test Setup Photos INMC0746Test Setup Photos2012-02-21PDF 378.9 KB
Test Setup Photos INMC0746.1Test Setup Photos2012-02-21PDF 373.3 KB
Test Setup Photos INMC0746.2Test Setup Photos2012-02-21PDF 373.3 KB
Test Setup Photos INMC0747Test Setup Photos2012-02-21PDF 349.3 KB
Test Setup Photos INMC0747.1Test Setup Photos2012-02-21PDF 765.2 KB
Test Setup Photos ITRM0248.1 SAR Report 1000CP02STest Setup Photos2011-12-01PDF 816.3 KB
Test Setup Photos ITRM0248.3 SAR Report 1000CP01STest Setup Photos2011-12-01PDF 804.8 KB
Test Setup Photos DFS Report -INMC0648Test Setup Photos2011-12-01PDF 2.1 MB
Test Setup Photos INMC0575.3 15.407Test Setup Photos2011-12-01PDF 1.6 MB
Test Setup Photos ITRM0248 SAR Report 1000CP01STest Setup Photos2011-12-01PDF 826 KB
Test Setup Photos ITRM0248.2 SAR Report 1001CP01STest Setup Photos2011-12-01PDF 871.1 KB
Test Setup Photos ITRM0248.4 SAR Report 1000CP02STest Setup Photos2011-12-01PDF 793.8 KB
Test Setup Photos ITRM0248.5 SAR Report 1001CP01STest Setup Photos2011-12-01PDF 874.6 KB
Test Setup Photos ITRM0248.6Test Setup Photos2011-12-01PDF 659.7 KB
Test Setup Photos ITRM0248.7Test Setup Photos2011-12-01PDF 958 KB
Test Setup Photos ITRM0248.8Test Setup Photos2011-12-01PDF 1,023.5 KB
Test Setup Photos ITRM0250.1Test Setup Photos2011-12-01PDF 1.5 MB
Test Setup Photos-INMC0575 802.11Test Setup Photos2011-12-01PDF 2.8 MB
Test Setup Photos-INMC0575.1 BTTest Setup Photos2011-12-01PDF 1.5 MB
Test Setup Photos-ITRM0249Test Setup Photos2011-12-01PDF 894 KB
Test ReportTest Report2016-06-15PDF 2.3 MB
Test Report INMC0747Test Report2012-02-21PDF 430.1 KB
Test Report INMC0747.1Test Report2012-02-21PDF 405.5 KB
ITRM0250.1 Test ReportTest Report2011-09-15PDF 397.9 KB
Qualcomm Test ReportTest Report2011-09-15PDF 1.8 MB
Report-INMC0575 15.247 for 802.11 - standalone moduleTest Report2011-08-29PDF 4.5 MB
Report-INMC0575.1 15.247 Bluetooth - standalone moduleTest Report2011-08-29PDF 2.6 MB
Report-INMC0575.3 15.407 for 802.11A - standalone moduleTest Report2011-08-29PDF 4 MB
Report-INMC0648 Rev 1 DFS - systemTest Report2011-08-29PDF 588.2 KB
Report-ITRM0249 22H, 24E, 28 for UMTSTest Report2011-08-29PDF 538.8 KB
Test Report - QualcommTest Report2011-08-29PDF 1.8 MB
Agent Authorization LetterCover Letter(s)2016-06-15PDF 583 KB
Cover letterCover Letter(s)2016-06-15PDF 56.6 KB
Request for confidentialityCover Letter(s)2016-06-15PDF 57 KB
Agent Authorization letterCover Letter(s)2015-05-13PDF 583.5 KB
Compliance OpinionCover Letter(s)2015-05-13PDF 19.2 KB
Cover letterCover Letter(s)2015-05-13PDF 301.3 KB
Request for confidentiality letterCover Letter(s)2015-05-13PDF 233.2 KB
Agent AuthorizationCover Letter(s)2012-02-21PDF 33.8 KB
Compliance OpinionCover Letter(s)2012-02-21PDF 14.4 KB
Cover letterCover Letter(s)2012-02-21PDF 43.1 KB
Agent Authorization letterCover Letter(s)2011-09-15PDF 33.8 KB
Compliance OpinionCover Letter(s)2011-09-15PDF 16.5 KB
Cover letterCover Letter(s)2011-09-15PDF 43.6 KB
Request for ConfidentialityCover Letter(s)2011-09-15PDF 39.2 KB
Agent Authorization letter -SierraCover Letter(s)2011-08-29PDF 67.8 KB
Compliance OpinionCover Letter(s)2011-08-29PDF 42.2 KB
Cover letterCover Letter(s)2011-08-29PDF 42.2 KB
Request for ConfidentialityCover Letter(s)2011-08-29PDF 242.8 KB
MPE reportRF Exposure Info2015-05-13PDF 949.2 KB
SAR report pt 1 of 4RF Exposure Info2015-05-13PDF 2.9 MB
SAR report pt 2 of 4RF Exposure Info2015-05-13PDF 3.2 MB
SAR report pt 3 of 4RF Exposure Info2015-05-13PDF 2.9 MB
SAR report pt 4 of 4RF Exposure Info2015-05-13PDF 2.6 MB
SAR Report INMC0746 802.11RF Exposure Info2012-02-21PDF 4.6 MB
SAR Report INMC0746.1 CDMARF Exposure Info2012-02-21PDF 3.9 MB
SAR Report INMC0746.2 UMTSRF Exposure Info2012-02-21PDF 4.9 MB
SAR Report ITRM0248.6 model 1000CP01SRF Exposure Info2011-09-15PDF 2.8 MB
SAR Report ITRM0248.7 model 1000CP02SRF Exposure Info2011-09-15PDF 2.8 MB
SAR Report ITRM0248.8 model 1001CP01SRF Exposure Info2011-09-15PDF 2.7 MB
Report-ITRM0248 SAR Report UMTS 1000CP01SRF Exposure Info2011-08-29PDF 4.4 MB
Report-ITRM0248.1 SAR Report UMTS 1000CP02SRF Exposure Info2011-08-29PDF 4.3 MB
Report-ITRM0248.2 SAR Report UMTS 1001CP01SRF Exposure Info2011-08-29PDF 4.6 MB
Report-ITRM0248.3 SAR Report 802.11 1000CP01SRF Exposure Info2011-08-29PDF 2.4 MB
Report-ITRM0248.4 SAR Report 802.11 1000CP02SRF Exposure Info2011-08-29PDF 2.5 MB
Report-ITRM0248.5 SAR Report 802.11 1001CP01SRF Exposure Info2011-08-29PDF 2.4 MB
Operational Description Metadata onlyOperational DescriptionPDF 48 KB
Software Security Metadata onlyOperational DescriptionPDF 54.5 KB

Application Information

Application ID6XfA0X1YQlSKQHjb8PHXWw==
Final Action Date2016-06-15
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0022970339
Model1000CP01SX1
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device Description1000CP01S, 1000CP02S, 1001CP01S
Responsible PartyBrian Rudick, VP & GC, Honeywell Scanning & Mobility, brian.rudick@honeywell.com , 803-835-8769
Test FirmRenee Walker, Element Materials Technology Seattle, Renee.Walker@element.com , 503-844-4066
TCB Emailgkiemel@nwemc.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for previous filings. Body-worn operations are restricted to the holsters tested for previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head: PCE 0.60 W/kg, DTS 0.10 W/kg, NII 0.14 W/kg; body-worn accessory: PCE 1.09 W/kg, DTS 0.31 W/kg, NII 0.50 W/kg; and extremity (hand) exposure conditions: PCE < 0.10 W/kg. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.

Applications

Application IDDatePurpose
6XfA0X1YQlSKQHjb8PHXWw==2016-06-15Class II permissive change or modification of presently authorized equipment
2mfXuYCGlkisFm0mRSR8SQ==2016-06-15Class II permissive change or modification of presently authorized equipment
tHDNIluHyvkRTD+0+JO1lQ==2015-05-13Class II permissive change or modification of presently authorized equipment
dpIaLveZDCLOG1BgAGWtGQ==2015-05-13Class II permissive change or modification of presently authorized equipment
dC7xdMiKWH58mUFiSPg+qA==2015-05-13Class II permissive change or modification of presently authorized equipment
gOCBVqH6tUZ7gKAK9rNslA==2012-02-21Class II permissive change or modification of presently authorized equipment
ZRvxdthlmyuZgOJRKt3CFg==2012-02-21Class II permissive change or modification of presently authorized equipment
O3/csH4RXqVxpF8FMiZuJA==2012-02-21Class II permissive change or modification of presently authorized equipment
VQqq5Ebsochb5Tx68QZ4RQ==2011-09-15Class II permissive change or modification of presently authorized equipment
SStpC+S+Gi7QVtsLfAOLFA==2011-09-15Class II permissive change or modification of presently authorized equipment
OliJXn5bpmb/BSTsYQ5+rw==2011-09-15Class II permissive change or modification of presently authorized equipment
il7LRKqNQw09l5Drm8m1eA==2011-08-29Original Equipment
Yf+ZFeTrgb2UvJlgr/E3fg==2011-08-29Original Equipment
BUu3qvls1qsBSQPA50+r6A==2011-08-29Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.2-848.8 MHz1.122.5ppm248KGXW22H
824.2-848.8 MHz1.092.5ppm248KG7W22H
824.7-848.31 MHz0.5272.5ppm1M28F9W22H
826.4-846.6 MHz0.1372.5ppm4M19F9W22H
1712.4-1752.6 MHz0.4422.5ppm4M15F9W27
1850.2-1909.8 MHz1.562.5ppm250KGXW24E
1850.2-1909.8 MHz1.322.5ppm245KG7W24E
1851.25-1908.75 MHz1.522.5ppm1M28F9W24E
1852.4-1907.6 MHz0.762.5ppm4M19F9W24E
1852.4-1907.5 MHz0.762.5ppm4M19F9W24E
2402-2480 MHz0.007215CCC
2412-2462 MHz0.053215CCC
5180-5240 MHz0.025115E38, CC
5180-5240 MHz0.025115ECC
5260-5320 MHz0.024515E38, CC, ND
5260-5320 MHz0.024515ECC
5500-5700 MHz0.019515E38, CC, ND
5500-5700 MHz0.019515ECC
5745-5825 MHz0.01715CCC
5745-5825 MHz0.018215E38, CC

Grants

TCB Grant - Application ZRvxdthlmyuZgOJRKt3CFg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Northwest EMC, Inc.
22975 NW Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 02/21/2012

Application Dated: 02/21/2012
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 1000CP01S, 1000CP02S, 1001CP01S, 1000CP03S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0251  
CC 15E 5260.0  -  5320.0 0.0245  
CC 15E 5500.0  -  5700.0 0.0195  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.44 - body-worn: 0.79; Part 24 Head: 0.72 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application ZRvxdthlmyuZgOJRKt3CFg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 02/21/2012

Application Dated: 02/21/2012
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 1000CP01S, 1000CP02S, 1001CP01S, 1000CP03S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0251  
CC 15E 5260.0  -  5320.0 0.0245  
CC 15E 5500.0  -  5700.0 0.0195  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.44 - body-worn: 0.79; Part 24 Head: 0.72 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application Yf+ZFeTrgb2UvJlgr/E3fg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Northwest EMC, Inc.
22975 NW Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 08/29/2011

Application Dated: 08/29/2011
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.12 2.5  PM 248KGXW
22H 824.2  -  848.8 1.09 2.5  PM 248KG7W
22H 826.4  -  846.6 0.137 2.5  PM 4M19F9W
24E 1850.2  -  1909.8 1.56 2.5  PM 250KGXW
24E 1850.2  -  1909.8 1.32 2.5  PM 245KG7W
24E 1852.4  -  1907.6 0.76 2.5  PM 4M19F9W
27 1712.4  -  1752.6 0.442 2.5  PM 4M15F9W

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.36 - body-worn: 0.58; Part 24 Head: 0.52 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


EAS Grant - Application Yf+ZFeTrgb2UvJlgr/E3fg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 08/29/2011

Application Dated: 08/29/2011
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.12 2.5  PM 248KGXW
22H 824.2  -  848.8 1.09 2.5  PM 248KG7W
22H 826.4  -  846.6 0.137 2.5  PM 4M19F9W
24E 1850.2  -  1909.8 1.56 2.5  PM 250KGXW
24E 1850.2  -  1909.8 1.32 2.5  PM 245KG7W
24E 1852.4  -  1907.6 0.76 2.5  PM 4M19F9W
27 1712.4  -  1752.6 0.442 2.5  PM 4M15F9W

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.36 - body-worn: 0.58; Part 24 Head: 0.52 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.



TCB Grant - Application VQqq5Ebsochb5Tx68QZ4RQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Northwest EMC, Inc.
22975 NW Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 09/15/2011

Application Dated: 09/15/2011
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.12 2.5  PM 248KGXW
22H 824.2  -  848.8 1.09 2.5  PM 248KG7W
22H 826.4  -  846.6 0.137 2.5  PM 4M19F9W
22H 824.7  -  848.31 0.527 2.5  PM 1M28F9W
24E 1850.2  -  1909.8 1.56 2.5  PM 250KGXW
24E 1850.2  -  1909.8 1.32 2.5  PM 245KG7W
24E 1852.4  -  1907.5 0.76 2.5  PM 4M19F9W
24E 1851.25  -  1908.75 1.52 2.5  PM 1M28F9W
27 1712.4  -  1752.6 0.442 2.5  PM 4M15F9W

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.41 - body-worn: 0.58; Part 24 Head: 0.52 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


EAS Grant - Application VQqq5Ebsochb5Tx68QZ4RQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 09/15/2011

Application Dated: 09/15/2011
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.12 2.5  PM 248KGXW
22H 824.2  -  848.8 1.09 2.5  PM 248KG7W
22H 826.4  -  846.6 0.137 2.5  PM 4M19F9W
22H 824.7  -  848.31 0.527 2.5  PM 1M28F9W
24E 1850.2  -  1909.8 1.56 2.5  PM 250KGXW
24E 1850.2  -  1909.8 1.32 2.5  PM 245KG7W
24E 1852.4  -  1907.5 0.76 2.5  PM 4M19F9W
24E 1851.25  -  1908.75 1.52 2.5  PM 1M28F9W
27 1712.4  -  1752.6 0.442 2.5  PM 4M15F9W

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.41 - body-worn: 0.58; Part 24 Head: 0.52 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.



TCB Grant - Application tHDNIluHyvkRTD+0+JO1lQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Element Materials Technology Portland - Evergreen
6775 NE Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 05/13/2015

Application Dated: 05/13/2015
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0251  
CC 15E 5260.0  -  5320.0 0.0245  
CC 15E 5500.0  -  5700.0 0.0195  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for previous filings. Body-worn operations are restricted to the holsters tested for previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head: PCE 0.60 W/kg, DTS 0.10 W/kg, NII 0.14 W/kg; body-worn accessory: PCE 1.09 W/kg, DTS 0.31 W/kg, NII 0.50 W/kg; and extremity (hand) exposure conditions: PCE < 0.10 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application tHDNIluHyvkRTD+0+JO1lQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 05/13/2015

Application Dated: 05/13/2015
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0251  
CC 15E 5260.0  -  5320.0 0.0245  
CC 15E 5500.0  -  5700.0 0.0195  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for previous filings. Body-worn operations are restricted to the holsters tested for previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head: PCE 0.60 W/kg, DTS 0.10 W/kg, NII 0.14 W/kg; body-worn accessory: PCE 1.09 W/kg, DTS 0.31 W/kg, NII 0.50 W/kg; and extremity (hand) exposure conditions: PCE < 0.10 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application SStpC+S+Gi7QVtsLfAOLFA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Northwest EMC, Inc.
22975 NW Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 09/15/2011

Application Dated: 09/15/2011
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Digital Transmission System
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0532  
CC 15C 2402.0  -  2480.0 0.0072  
CC 15C 5745.0  -  5825.0 0.017  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.41 - body-worn: 0.58; Part 24 Head: 0.52 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application SStpC+S+Gi7QVtsLfAOLFA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 09/15/2011

Application Dated: 09/15/2011
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Digital Transmission System
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0532  
CC 15C 2402.0  -  2480.0 0.0072  
CC 15C 5745.0  -  5825.0 0.017  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.41 - body-worn: 0.58; Part 24 Head: 0.52 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application OliJXn5bpmb/BSTsYQ5+rw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Northwest EMC, Inc.
22975 NW Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 09/15/2011

Application Dated: 09/15/2011
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0251  
CC 15E 5260.0  -  5320.0 0.0245  
CC 15E 5500.0  -  5700.0 0.0195  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.41 - body-worn: 0.58; Part 24 Head: 0.52 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application OliJXn5bpmb/BSTsYQ5+rw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 09/15/2011

Application Dated: 09/15/2011
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0251  
CC 15E 5260.0  -  5320.0 0.0245  
CC 15E 5500.0  -  5700.0 0.0195  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.41 - body-worn: 0.58; Part 24 Head: 0.52 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application O3/csH4RXqVxpF8FMiZuJA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Northwest EMC, Inc.
22975 NW Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 02/21/2012

Application Dated: 02/21/2012
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: 1000CP01S, 1000CP02S, 1001CP01S, 1000CP03S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.12 2.5  PM 248KGXW
22H 824.2  -  848.8 1.09 2.5  PM 248KG7W
22H 826.4  -  846.6 0.137 2.5  PM 4M19F9W
24E 1850.2  -  1909.8 1.56 2.5  PM 250KGXW
24E 1850.2  -  1909.8 1.32 2.5  PM 245KG7W
24E 1852.4  -  1907.6 0.76 2.5  PM 4M19F9W
27 1712.4  -  1752.6 0.442 2.5  PM 4M15F9W

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.44 - body-worn: 0.79; Part 24 Head: 0.72 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


EAS Grant - Application O3/csH4RXqVxpF8FMiZuJA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 02/21/2012

Application Dated: 02/21/2012
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: 1000CP01S, 1000CP02S, 1001CP01S, 1000CP03S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.12 2.5  PM 248KGXW
22H 824.2  -  848.8 1.09 2.5  PM 248KG7W
22H 826.4  -  846.6 0.137 2.5  PM 4M19F9W
24E 1850.2  -  1909.8 1.56 2.5  PM 250KGXW
24E 1850.2  -  1909.8 1.32 2.5  PM 245KG7W
24E 1852.4  -  1907.6 0.76 2.5  PM 4M19F9W
27 1712.4  -  1752.6 0.442 2.5  PM 4M15F9W

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.44 - body-worn: 0.79; Part 24 Head: 0.72 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.



TCB Grant - Application il7LRKqNQw09l5Drm8m1eA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Northwest EMC, Inc.
22975 NW Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 08/29/2011

Application Dated: 08/29/2011
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Digital Transmission System
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0532  
CC 15C 2402.0  -  2480.0 0.0072  
CC 15C 5745.0  -  5825.0 0.017  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.36 - body-worn: 0.58; Part 24 Head: 0.52 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application il7LRKqNQw09l5Drm8m1eA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 08/29/2011

Application Dated: 08/29/2011
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Digital Transmission System
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0532  
CC 15C 2402.0  -  2480.0 0.0072  
CC 15C 5745.0  -  5825.0 0.017  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.36 - body-worn: 0.58; Part 24 Head: 0.52 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application gOCBVqH6tUZ7gKAK9rNslA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Northwest EMC, Inc.
22975 NW Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 02/21/2012

Application Dated: 02/21/2012
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Digital Transmission System
Notes: 1000CP01S, 1000CP02S, 1001CP01S, 1000CP03S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0532  
CC 15C 2402.0  -  2480.0 0.0072  
CC 15C 5745.0  -  5825.0 0.017  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.44 - body-worn: 0.79; Part 24 Head: 0.72 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application gOCBVqH6tUZ7gKAK9rNslA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 02/21/2012

Application Dated: 02/21/2012
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Digital Transmission System
Notes: 1000CP01S, 1000CP02S, 1001CP01S, 1000CP03S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0532  
CC 15C 2402.0  -  2480.0 0.0072  
CC 15C 5745.0  -  5825.0 0.017  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.44 - body-worn: 0.79; Part 24 Head: 0.72 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application dpIaLveZDCLOG1BgAGWtGQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Element Materials Technology Portland - Evergreen
6775 NE Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 05/13/2015

Application Dated: 05/13/2015
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.12 2.5  PM 248KGXW
22H 824.2  -  848.8 1.09 2.5  PM 248KG7W
22H 826.4  -  846.6 0.137 2.5  PM 4M19F9W
24E 1850.2  -  1909.8 1.56 2.5  PM 250KGXW
24E 1850.2  -  1909.8 1.32 2.5  PM 245KG7W
24E 1852.4  -  1907.6 0.76 2.5  PM 4M19F9W
27 1712.4  -  1752.6 0.442 2.5  PM 4M15F9W

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for previous filings. Body-worn operations are restricted to the holsters tested for previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head: PCE 0.60 W/kg, DTS 0.10 W/kg, NII 0.14 W/kg; body-worn accessory: PCE 1.09 W/kg, DTS 0.31 W/kg, NII 0.50 W/kg; and extremity (hand) exposure conditions: PCE < 0.10 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


EAS Grant - Application dpIaLveZDCLOG1BgAGWtGQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 05/13/2015

Application Dated: 05/13/2015
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.12 2.5  PM 248KGXW
22H 824.2  -  848.8 1.09 2.5  PM 248KG7W
22H 826.4  -  846.6 0.137 2.5  PM 4M19F9W
24E 1850.2  -  1909.8 1.56 2.5  PM 250KGXW
24E 1850.2  -  1909.8 1.32 2.5  PM 245KG7W
24E 1852.4  -  1907.6 0.76 2.5  PM 4M19F9W
27 1712.4  -  1752.6 0.442 2.5  PM 4M15F9W

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for previous filings. Body-worn operations are restricted to the holsters tested for previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head: PCE 0.60 W/kg, DTS 0.10 W/kg, NII 0.14 W/kg; body-worn accessory: PCE 1.09 W/kg, DTS 0.31 W/kg, NII 0.50 W/kg; and extremity (hand) exposure conditions: PCE < 0.10 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.



TCB Grant - Application dC7xdMiKWH58mUFiSPg+qA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Element Materials Technology Portland - Evergreen
6775 NE Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 05/13/2015

Application Dated: 05/13/2015
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Digital Transmission System
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0532  
CC 15C 2402.0  -  2480.0 0.0072  
CC 15C 5745.0  -  5825.0 0.017  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for previous filings. Body-worn operations are restricted to the holsters tested for previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head: PCE 0.60 W/kg, DTS 0.10 W/kg, NII 0.14 W/kg; body-worn accessory: PCE 1.09 W/kg, DTS 0.31 W/kg, NII 0.50 W/kg; and extremity (hand) exposure conditions: PCE < 0.10 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application dC7xdMiKWH58mUFiSPg+qA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 05/13/2015

Application Dated: 05/13/2015
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Digital Transmission System
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0532  
CC 15C 2402.0  -  2480.0 0.0072  
CC 15C 5745.0  -  5825.0 0.017  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for previous filings. Body-worn operations are restricted to the holsters tested for previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head: PCE 0.60 W/kg, DTS 0.10 W/kg, NII 0.14 W/kg; body-worn accessory: PCE 1.09 W/kg, DTS 0.31 W/kg, NII 0.50 W/kg; and extremity (hand) exposure conditions: PCE < 0.10 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application BUu3qvls1qsBSQPA50+r6A==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Northwest EMC, Inc.
22975 NW Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 08/29/2011

Application Dated: 08/29/2011
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0251  
CC 15E 5260.0  -  5320.0 0.0245  
CC 15E 5500.0  -  5700.0 0.0195  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.36 - body-worn: 0.58; Part 24 Head: 0.52 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application BUu3qvls1qsBSQPA50+r6A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 08/29/2011

Application Dated: 08/29/2011
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0251  
CC 15E 5260.0  -  5320.0 0.0245  
CC 15E 5500.0  -  5700.0 0.0195  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22 Head: 0.36 - body-worn: 0.58; Part 24 Head: 0.52 - body-worn: 1.09; Part 27 Head: 0.60 - body-worn: 0.85; Part 15 Head: 0.14 W/kg - Body-worn: 0.50 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 6XfA0X1YQlSKQHjb8PHXWw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Element Materials Technology Portland - Evergreen
6775 NE Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 06/15/2016

Application Dated: 06/15/2016
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.0251  
38 CC ND 15E 5260.0  -  5320.0 0.0245  
38 CC ND 15E 5500.0  -  5700.0 0.0195  
38 CC 15E 5745.0  -  5825.0 0.0182  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for previous filings. Body-worn operations are restricted to the holsters tested for previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head: PCE 0.60 W/kg, DTS 0.10 W/kg, NII 0.14 W/kg; body-worn accessory: PCE 1.09 W/kg, DTS 0.31 W/kg, NII 0.50 W/kg; and extremity (hand) exposure conditions: PCE < 0.10 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application 6XfA0X1YQlSKQHjb8PHXWw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 06/15/2016

Application Dated: 06/15/2016
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC 15E 5180.0  -  5240.0 0.0251  
38 CC ND 15E 5260.0  -  5320.0 0.0245  
38 CC ND 15E 5500.0  -  5700.0 0.0195  
38 CC 15E 5745.0  -  5825.0 0.0182  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for previous filings. Body-worn operations are restricted to the holsters tested for previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head: PCE 0.60 W/kg, DTS 0.10 W/kg, NII 0.14 W/kg; body-worn accessory: PCE 1.09 W/kg, DTS 0.31 W/kg, NII 0.50 W/kg; and extremity (hand) exposure conditions: PCE < 0.10 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application 2mfXuYCGlkisFm0mRSR8SQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Element Materials Technology Portland - Evergreen
6775 NE Evergreen Parkway, Suite 400
Hillsboro, OR 97124
Date of Grant: 06/15/2016

Application Dated: 06/15/2016
Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Digital Transmission System
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0072  
CC 15C 2412.0  -  2462.0 0.0532  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for previous filings. Body-worn operations are restricted to the holsters tested for previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head: PCE 0.60 W/kg, DTS 0.10 W/kg, NII 0.14 W/kg; body-worn accessory: PCE 1.09 W/kg, DTS 0.31 W/kg, NII 0.50 W/kg; and extremity (hand) exposure conditions: PCE < 0.10 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 2mfXuYCGlkisFm0mRSR8SQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Intermec Technologies Corporation
9680 Old Bailes Rd.
Fort Mill, SC 29707
United States
  Date of Grant: 06/15/2016

Application Dated: 06/15/2016
 
Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EHA-1000CP01SX1
Name of Grantee:  Intermec Technologies Corporation
Equipment Class: Digital Transmission System
Notes: 1000CP01S, 1000CP02S, 1001CP01S
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0072  
CC 15C 2412.0  -  2462.0 0.0532  

Power listed is ERP for Part 22 and EIRP for Parts 24 and 27. Output power is conducted for Part 15. Approval is for operation as a client only device without radar detection. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for previous filings. Body-worn operations are restricted to the holsters tested for previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head: PCE 0.60 W/kg, DTS 0.10 W/kg, NII 0.14 W/kg; body-worn accessory: PCE 1.09 W/kg, DTS 0.31 W/kg, NII 0.50 W/kg; and extremity (hand) exposure conditions: PCE < 0.10 W/kg.

This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: