FCC ID EHA-1000CP01X2
1000CP01, 1000CP02, 1001CP01
by Intermec Technologies Corporation
Grantee Code: EHA Product Code: 1000CP01X2
Latest application date: 2016-06-15
FCC ID Device Details
| FCC ID | EHA-1000CP01X2 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | EHA |
| Product Code | 1000CP01X2 |
| Applicant Business | Intermec Technologies Corporation 🇺🇸 |
| Related Domains | |
| Equipment Class | 1000CP01, 1000CP02, 1001CP01 |
| Test Firm | Element Materials Technology Seattle |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2016-06-15 |
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2016-06-15 |
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2015-05-08 |
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2015-05-08 |
| 5180-5240 MHz | Original Equipment | 2010-12-23 |
| 2402-2480 MHz | Original Equipment | 2010-12-23 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Compliance Insert 1000CP01 | Users Manual | 2010-12-27 | PDF 973 KB |
| Compliance Insert 1000CP02 | Users Manual | 2010-12-27 | PDF 973 KB |
| Compliance Insert 1001CP01 | Users Manual | 2010-12-27 | PDF 973.4 KB |
| Cozumel Users Manual | Users Manual | 2010-12-27 | PDF 5.6 MB |
| QSG 1000CP01 | Users Manual | 2010-12-27 | PDF 976.3 KB |
| QSG 1000CP02 | Users Manual | 2010-12-27 | PDF 794.3 KB |
| QSG 1001CP01 | Users Manual | 2010-12-27 | PDF 892.1 KB |
| Internal Photos | Internal Photos | 2015-05-08 | PDF 4.7 MB |
| Internal Photos 1000CP01 | Internal Photos | 2010-12-27 | PDF 545.4 KB |
| Internal Photos 1000CP02 | Internal Photos | 2010-12-27 | PDF 732.4 KB |
| Internal Photos 1001CP01 | Internal Photos | 2010-12-27 | PDF 949.1 KB |
| External Photos | External Photos | 2015-05-08 | PDF 648.3 KB |
| External photos | External Photos | 2015-05-08 | PDF 3.4 MB |
| External Photos 1000CP01 | External Photos | 2010-12-27 | PDF 967.5 KB |
| External Photos 1000CP02 | External Photos | 2010-12-27 | PDF 1.8 MB |
| External Photos 1001CP01 | External Photos | 2010-12-27 | PDF 3.1 MB |
| ID Label 1000CP01 | ID Label/Location Info | 2010-12-23 | PDF 353.1 KB |
| ID Label 1000CP02 | ID Label/Location Info | 2010-12-23 | PDF 112.7 KB |
| ID Label 1001CP01 | ID Label/Location Info | 2010-12-23 | PDF 109.9 KB |
| Antenna Info - installed in EUT | Operational Description | 2010-12-23 | PDF 5.4 MB |
| Antenna Info - standalone | Operational Description | 2010-12-23 | PDF 4.4 MB |
| Test Setup Photos | Test Setup Photos | 2016-06-15 | PDF 912.7 KB |
| Test setup Photos | Test Setup Photos | 2015-05-08 | PDF 611 KB |
| Test Setup Photos DFS Report | Test Setup Photos | 2010-12-27 | PDF 2.1 MB |
| Test Setup Photos INMC0575 | Test Setup Photos | 2010-12-27 | PDF 2.7 MB |
| Test Setup Photos INMC0575.1 | Test Setup Photos | 2010-12-27 | PDF 1.5 MB |
| Test Setup Photos INMC0575.3 | Test Setup Photos | 2010-12-27 | PDF 1.5 MB |
| Test Setup Photos INMC0650 | Test Setup Photos | 2010-12-27 | PDF 632.5 KB |
| Test Setup Photos INMC0650.1 | Test Setup Photos | 2010-12-27 | PDF 632.5 KB |
| Test Setup Photos INMC0650.2 | Test Setup Photos | 2010-12-27 | PDF 632.5 KB |
| Test Report | Test Report | 2016-06-15 | PDF 2.3 MB |
| DFS Report Rev 1 | Test Report | 2010-12-23 | PDF 588.2 KB |
| Test Report INMC0575 15.247 for 802.11 | Test Report | 2010-12-23 | PDF 4.5 MB |
| Test Report INMC0575.1 15.247 BT | Test Report | 2010-12-23 | PDF 2.6 MB |
| Test Report INMC0575.3 15.407 | Test Report | 2010-12-23 | PDF 4 MB |
| Test Report INMC0650 15.247 for 802.11 System | Test Report | 2010-12-23 | PDF 357.2 KB |
| Test Report INMC0650.1 15.247 BT system | Test Report | 2010-12-23 | PDF 347.2 KB |
| Test Report INMC0650.2 15.407 802.11A system | Test Report | 2010-12-23 | PDF 355.7 KB |
| Agent Authorization Letter | Cover Letter(s) | 2016-06-15 | PDF 583 KB |
| Cover letter | Cover Letter(s) | 2016-06-15 | PDF 56.7 KB |
| Request for confidentiality | Cover Letter(s) | 2016-06-15 | PDF 57 KB |
| Agent Authorization letter | Cover Letter(s) | 2015-05-08 | PDF 583.5 KB |
| Compliance Opinion | Cover Letter(s) | 2015-05-08 | PDF 19 KB |
| Cover letter | Cover Letter(s) | 2015-05-08 | PDF 301.2 KB |
| Agent Authorization letter | Cover Letter(s) | 2010-12-23 | PDF 78.8 KB |
| Compliance Opinion | Cover Letter(s) | 2010-12-23 | PDF 17.2 KB |
| Cover letter | Cover Letter(s) | 2010-12-23 | PDF 38.9 KB |
| Letter requesting exhibit be superseded | Cover Letter(s) | 2010-12-23 | PDF 7.2 KB |
| Request for Confidentiality | Cover Letter(s) | 2010-12-23 | PDF 41.7 KB |
| MPE report | RF Exposure Info | 2015-05-08 | PDF 949.2 KB |
| SAR report pt 1 of 4 | RF Exposure Info | 2015-05-08 | PDF 2.9 MB |
| SAR report pt 2 of 4 | RF Exposure Info | 2015-05-08 | PDF 3.2 MB |
| SAR report pt 3 of 4 | RF Exposure Info | 2015-05-08 | PDF 2.9 MB |
| SAR report pt 4 of 4 | RF Exposure Info | 2015-05-08 | PDF 2.6 MB |
| CK71 SAR report part 1 of 4 | RF Exposure Info | 2010-12-23 | PDF 4.6 MB |
| CK71 SAR report part 2 of 4 | RF Exposure Info | 2010-12-23 | PDF 2.8 MB |
| CK71 SAR report part 3 of 4 | RF Exposure Info | 2010-12-23 | PDF 1.4 MB |
| CK71 SAR report part 4 of 4 | RF Exposure Info | 2010-12-23 | PDF 495.6 KB |
| CN70 SAR report part 1 of 4 | RF Exposure Info | 2010-12-23 | PDF 4.2 MB |
| CN70 SAR report part 2 of 4 | RF Exposure Info | 2010-12-23 | PDF 3 MB |
| CN70 SAR report part 3 of 4 | RF Exposure Info | 2010-12-23 | PDF 1.4 MB |
| CN70 SAR report part 4 of 4 | RF Exposure Info | 2010-12-23 | PDF 495.9 KB |
| CN70E SAR report part 1 of 4 | RF Exposure Info | 2010-12-23 | PDF 4.1 MB |
| CN70E SAR report part 2 of 4 | RF Exposure Info | 2010-12-23 | PDF 2.9 MB |
| CN70E SAR report part 3of 4 | RF Exposure Info | 2010-12-23 | PDF 1.4 MB |
| CN70E SAR report part 4 of 4 | RF Exposure Info | 2010-12-23 | PDF 496.2 KB |
| Software Security Metadata only | Operational Description | PDF 54.5 KB |
Application Information
| Application ID | VSAwkhCQvVyLn3HdstnujQ== |
|---|---|
| Final Action Date | 2016-06-15 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0022970339 |
| Model | 1000CP01X2 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | 1000CP01, 1000CP02, 1001CP01 |
| Responsible Party | Brian Rudick, VP & GC, Honeywell Scanning & Mobility, brian.rudick@honeywell.com |
| Agent | Sean Sean Sean, Intermec Technologies, sean.mackellar@honeywell.com |
| Test Firm | Renee Walker, Element Materials Technology Seattle, Renee.Walker@element.com |
| TCB Email | gkiemel@nwemc.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for in previous filings. Body-worn operations are restricted to the holsters tested for in previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| VSAwkhCQvVyLn3HdstnujQ== | 2016-06-15 | Class II permissive change or modification of presently authorized equipment |
| T1ULovO0R1M1UYIZY59Q4w== | 2016-06-15 | Class II permissive change or modification of presently authorized equipment |
| OuK1SfoMDucIzTXFLJiO0w== | 2015-05-08 | Class II permissive change or modification of presently authorized equipment |
| EadNPdxrn7mxtWg96ZnYHg== | 2015-05-08 | Class II permissive change or modification of presently authorized equipment |
| ajDlt0QC+j/7VdIOQeKtzg== | 2010-12-23 | Original Equipment |
| 0LcGoB7egC8pmzcDDwBzzQ== | 2010-12-23 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application VSAwkhCQvVyLn3HdstnujQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Element Materials Technology Portland - Evergreen 6775 NE Evergreen Parkway, Suite 400 Hillsboro, OR 97124 |
Date of Grant: 06/15/2016 Application Dated: 06/15/2016 |
| Intermec Technologies Corporation |
| 9680 Old Bailes Rd. |
| Fort Mill, SC 29707 |
| Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EHA-1000CP01X2 |
| Name of Grantee: | Intermec Technologies Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | 1000CP01, 1000CP02, 1001CP01 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0072 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.0532 |
| Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for in previous filings. Body-worn operations are restricted to the holsters tested for in previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application VSAwkhCQvVyLn3HdstnujQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Intermec Technologies Corporation 9680 Old Bailes Rd. Fort Mill, SC 29707 United States |
Date of Grant: 06/15/2016 Application Dated: 06/15/2016 |
| Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EHA-1000CP01X2 |
| Name of Grantee: | Intermec Technologies Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | 1000CP01, 1000CP02, 1001CP01 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0072 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.0532 |
| Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for in previous filings. Body-worn operations are restricted to the holsters tested for in previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Element Materials Technology Portland - Evergreen 6775 NE Evergreen Parkway, Suite 400 Hillsboro, OR 97124 |
Date of Grant: 06/15/2016 Application Dated: 06/15/2016 |
| Intermec Technologies Corporation |
| 9680 Old Bailes Rd. |
| Fort Mill, SC 29707 |
| Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EHA-1000CP01X2 |
| Name of Grantee: | Intermec Technologies Corporation |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 1000CP01, 1000CP02, 1001CP01 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC | 15E | 5180.0 - 5240.0 | 0.0251 | ||
| 38 CC ND | 15E | 5260.0 - 5320.0 | 0.0245 | ||
| 38 CC ND | 15E | 5500.0 - 5700.0 | 0.0195 | ||
| 38 CC | 15E | 5745.0 - 5825.0 | 0.0182 |
| Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for in previous filings. Body-worn operations are restricted to the holsters tested for in previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application T1ULovO0R1M1UYIZY59Q4w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Intermec Technologies Corporation 9680 Old Bailes Rd. Fort Mill, SC 29707 United States |
Date of Grant: 06/15/2016 Application Dated: 06/15/2016 |
| Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EHA-1000CP01X2 |
| Name of Grantee: | Intermec Technologies Corporation |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 1000CP01, 1000CP02, 1001CP01 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC | 15E | 5180.0 - 5240.0 | 0.0251 | ||
| 38 CC ND | 15E | 5260.0 - 5320.0 | 0.0245 | ||
| 38 CC ND | 15E | 5500.0 - 5700.0 | 0.0195 | ||
| 38 CC | 15E | 5745.0 - 5825.0 | 0.0182 |
| Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for in previous filings. Body-worn operations are restricted to the holsters tested for in previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Element Materials Technology Portland - Evergreen 6775 NE Evergreen Parkway, Suite 400 Hillsboro, OR 97124 |
Date of Grant: 05/08/2015 Application Dated: 05/08/2015 |
| Intermec Technologies Corporation |
| 9680 Old Bailes Rd. |
| Fort Mill, SC 29707 |
| Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EHA-1000CP01X2 |
| Name of Grantee: | Intermec Technologies Corporation |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 1000CP01, 1000CP02, 1001CP01 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0251 | ||
| CC | 15E | 5260.0 - 5320.0 | 0.0245 | ||
| CC | 15E | 5500.0 - 5700.0 | 0.0195 |
| Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for in previous filings. Body-worn operations are restricted to the holsters tested for in previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application OuK1SfoMDucIzTXFLJiO0w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Intermec Technologies Corporation 9680 Old Bailes Rd. Fort Mill, SC 29707 United States |
Date of Grant: 05/08/2015 Application Dated: 05/08/2015 |
| Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EHA-1000CP01X2 |
| Name of Grantee: | Intermec Technologies Corporation |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 1000CP01, 1000CP02, 1001CP01 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0251 | ||
| CC | 15E | 5260.0 - 5320.0 | 0.0245 | ||
| CC | 15E | 5500.0 - 5700.0 | 0.0195 |
| Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for in previous filings. Body-worn operations are restricted to the holsters tested for in previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Element Materials Technology Portland - Evergreen 6775 NE Evergreen Parkway, Suite 400 Hillsboro, OR 97124 |
Date of Grant: 05/08/2015 Application Dated: 05/08/2015 |
| Intermec Technologies Corporation |
| 9680 Old Bailes Rd. |
| Fort Mill, SC 29707 |
| Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EHA-1000CP01X2 |
| Name of Grantee: | Intermec Technologies Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | 1000CP01, 1000CP02, 1001CP01 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.0532 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.0072 | ||
| CC | 15C | 5745.0 - 5825.0 | 0.017 |
| Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for in previous filings. Body-worn operations are restricted to the holsters tested for in previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application EadNPdxrn7mxtWg96ZnYHg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Intermec Technologies Corporation 9680 Old Bailes Rd. Fort Mill, SC 29707 United States |
Date of Grant: 05/08/2015 Application Dated: 05/08/2015 |
| Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EHA-1000CP01X2 |
| Name of Grantee: | Intermec Technologies Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | 1000CP01, 1000CP02, 1001CP01 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.0532 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.0072 | ||
| CC | 15C | 5745.0 - 5825.0 | 0.017 |
| Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for in previous filings. Body-worn operations are restricted to the holsters tested for in previous filings. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Northwest EMC, Inc. 22975 NW Evergreen Parkway, Suite 400 Hillsboro, OR 97124 |
Date of Grant: 12/23/2010 Application Dated: 12/23/2010 |
| Intermec Technologies Corporation |
| 9680 Old Bailes Rd. |
| Fort Mill, SC 29707 |
| Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EHA-1000CP01X2 |
| Name of Grantee: | Intermec Technologies Corporation |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 1000CP01, 1000CP02, 1001CP01 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0251 | ||
| CC | 15E | 5260.0 - 5320.0 | 0.0245 | ||
| CC | 15E | 5500.0 - 5700.0 | 0.0195 |
| Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application ajDlt0QC+j/7VdIOQeKtzg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Intermec Technologies Corporation 9680 Old Bailes Rd. Fort Mill, SC 29707 United States |
Date of Grant: 12/23/2010 Application Dated: 12/23/2010 |
| Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EHA-1000CP01X2 |
| Name of Grantee: | Intermec Technologies Corporation |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 1000CP01, 1000CP02, 1001CP01 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0251 | ||
| CC | 15E | 5260.0 - 5320.0 | 0.0245 | ||
| CC | 15E | 5500.0 - 5700.0 | 0.0195 |
| Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Northwest EMC, Inc. 22975 NW Evergreen Parkway, Suite 400 Hillsboro, OR 97124 |
Date of Grant: 12/23/2010 Application Dated: 12/23/2010 |
| Intermec Technologies Corporation |
| 9680 Old Bailes Rd. |
| Fort Mill, SC 29707 |
| Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EHA-1000CP01X2 |
| Name of Grantee: | Intermec Technologies Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | 1000CP01, 1000CP02, 1001CP01 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.0532 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.0072 | ||
| CC | 15C | 5745.0 - 5825.0 | 0.017 |
| Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application 0LcGoB7egC8pmzcDDwBzzQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Intermec Technologies Corporation 9680 Old Bailes Rd. Fort Mill, SC 29707 United States |
Date of Grant: 12/23/2010 Application Dated: 12/23/2010 |
| Attention: Brian Rudick , VP & GC, Honeywell Scanning & Mobility |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EHA-1000CP01X2 |
| Name of Grantee: | Intermec Technologies Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | 1000CP01, 1000CP02, 1001CP01 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.0532 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.0072 | ||
| CC | 15C | 5745.0 - 5825.0 | 0.017 |
| Output power is conducted. Client device per section 15.202 definition. Approval is for operation as a client only device without radar detection. Operation of this device in the 5150 MHz to 5250 MHz range is restricted to indoor use only. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to the holsters tested for this filing. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 1.47 W/kg; Body-worn: 0.69 W/kg |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |