FCC ID EO9100GDLD

AMR transceiver device for utility meters

by Itron, Inc.

Grantee Code: EO9   Product Code: 100GDLD
Latest application date: 2009-05-27

FCC ID Device Details

FCC IDEO9100GDLD
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeEO9
Product Code100GDLD
Applicant BusinessItron, Inc. 🇺🇸
Related Domains itron.com
Equipment ClassAMR transceiver device for utility meters
Test FirmItron, Inc

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
908 MHzOriginal Equipment2009-05-27
908-924 MHzOriginal Equipment2009-05-27

Exhibits

DocumentTypeAvailableFile
Users Manual Part 1Users Manual2009-05-27PDF 576.7 KB
Users Manual Part 1Test Setup Photos2009-05-27PDF 576.7 KB
Users Manual Part 2Users Manual2009-05-27PDF 1.3 MB
Users Manual Part 3Users Manual2009-05-27PDF 1.1 MB
Internal PhotosInternal Photos2009-05-27PDF 113.1 KB
External PhotosExternal Photos2009-05-27PDF 2.7 MB
LabelID Label/Location Info2009-05-27PDF 238.7 KB
Label LocationID Label/Location Info2009-05-27PDF 493.4 KB
Test Setup PhotosTest Setup Photos2009-05-27PDF 4 MB
Test Report 247Test Report2009-05-27PDF 239.4 KB
Test Report 249Test Report2009-05-27PDF 83.6 KB
Authorization LetterCover Letter(s)2009-05-27PDF 38.1 KB
Authorization Letter JayCover Letter(s)2009-05-27PDF 403.3 KB
Confidentiality LetterCover Letter(s)2009-05-27PDF 562 KB
Cover LetterCover Letter(s)2009-05-27PDF 596.7 KB
RF InfoRF Exposure Info2009-05-27PDF 18 KB

Application Information

Application IDianYcNaC0f+qVFkooGlSaw==
Final Action Date2009-05-27
Application PurposeOriginal Equipment
Applicant FRN0005861034
Model100GDLD
Frequency Range908 MHz
Equipment ClassDXT - Part 15 Low Power Transceiver, Rx Verified
Device DescriptionAMR transceiver device for utility meters
Responsible PartyJay R. Holcomb, R&D; Manager, Regulatory and Programs, jay.holcomb@itron.com , 509-891-3281
Technical ContactJay Holcomb, Itron, Inc., jay.holcomb@itron.com , 509-891-3281
Test FirmJay Holcomb, Itron, Inc, jay.holcomb@itron.com , 509-891-3281
TCB EmailTCBAdmin@ckccertification.com
TCB ScopeA1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
ianYcNaC0f+qVFkooGlSaw==2009-05-27Original Equipment
J9huXY0r1ux0IVyFq/WIzw==2009-05-27Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
908 MHz15CCC
908-924 MHz0.188000015CCC

Grants

TCB Grant - Application J9huXY0r1ux0IVyFq/WIzw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 05/27/2009

Application Dated: 05/21/2009
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9100GDLD
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for utility meters
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.0  -  924.0 0.188  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application J9huXY0r1ux0IVyFq/WIzw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 05/27/2009

Application Dated: 05/21/2009
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9100GDLD
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for utility meters
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.0  -  924.0 0.188  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application ianYcNaC0f+qVFkooGlSaw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 05/27/2009

Application Dated: 05/21/2009
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9100GDLD
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Low Power Transceiver, Rx Verified
Notes: AMR transceiver device for utility meters
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.0  -  908.0  


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application ianYcNaC0f+qVFkooGlSaw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 05/27/2009

Application Dated: 05/21/2009
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9100GDLD
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Low Power Transceiver, Rx Verified
Notes: AMR transceiver device for utility meters
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.0  -  908.0  


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: