FCC ID EO9100GDLR
AMR transceiver device for utility meters.
by Itron, Inc.
Grantee Code: EO9 Product Code: 100GDLR
Latest application date: 2009-07-24
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 908 MHz | Original Equipment | 2009-07-24 |
| 908-924 MHz | Original Equipment | 2009-07-24 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual Section 1 | Users Manual | 2009-07-24 | PDF 576.7 KB |
| Users Manual Section 2 | Users Manual | 2009-07-24 | PDF 1.3 MB |
| Users Manual Section 3 | Users Manual | 2009-07-24 | PDF 1.1 MB |
| External Photos | External Photos | 2009-07-24 | PDF 1.1 MB |
| Label | ID Label/Location Info | 2009-07-24 | PDF 268.6 KB |
| Label Location | ID Label/Location Info | 2009-07-24 | PDF 66.7 KB |
| Test Setup Photos | Test Setup Photos | 2009-07-24 | PDF 2.2 MB |
| Test Report 247 | Test Report | 2009-07-24 | PDF 220.4 KB |
| Test Report 249 | Test Report | 2009-07-24 | PDF 81.7 KB |
| Tset Report 249 | Test Report | 2009-07-24 | PDF 81.7 KB |
| Application Form | Cover Letter(s) | 2009-07-24 | PDF 111 KB |
| CKC Authorization Letter | Cover Letter(s) | 2009-07-24 | PDF 38.1 KB |
| Confidentiality Letter | Cover Letter(s) | 2009-07-24 | PDF 34.6 KB |
| Confidtentiality Letter | Cover Letter(s) | 2009-07-24 | PDF 34.6 KB |
| Cover Letter | Cover Letter(s) | 2009-07-24 | PDF 34.2 KB |
| JH Authorization Letter | Cover Letter(s) | 2009-07-24 | PDF 403.3 KB |
| TCB Correspondance | Cover Letter(s) | 2009-07-24 | PDF 53.1 KB |
Application Information
| Application ID | ahUSeAhDQkpyyaD4FAZa+A== |
|---|---|
| Final Action Date | 2009-07-24 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0005861034 |
| Model | 100GDLR |
| Frequency Range | 908 MHz |
| Equipment Class | DXT - Part 15 Low Power Transceiver, Rx Verified |
| Device Description | AMR transceiver device for utility meters. |
| Responsible Party | Jay R. Holcomb, R&D; Manager, Regulatory and Programs, jay.holcomb@itron.com |
| Technical Contact | Jay Holcomb, Itron, Inc., jay.holcomb@itron.com |
| Test Firm | Jay Holcomb, Itron, Inc, jay.holcomb@itron.com |
| TCB Email | TCB@ckccertification.com |
| TCB Scope | A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| ahUSeAhDQkpyyaD4FAZa+A== | 2009-07-24 | Original Equipment |
| JKnAi7KDjk23R96oLe35PA== | 2009-07-24 | Original Equipment |
Grants
TCB Grant - Application JKnAi7KDjk23R96oLe35PA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CKC Certification Services, LLC 5046 Sierra Pines Mariposa, CA 95338 |
Date of Grant: 07/24/2009 Application Dated: 07/20/2009 |
| Itron, Inc. |
| 2111 N. Molter Road |
| Liberty Lake, WA 99019 |
| Attention: Jay Holcomb , R&D Manager, Regulatory and Programs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EO9100GDLR |
| Name of Grantee: | Itron, Inc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | AMR transceiver device for utility meters. |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 908.0 - 924.0 | 0.143 |
| Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application JKnAi7KDjk23R96oLe35PA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Itron, Inc. 2111 N. Molter Road Liberty Lake, WA 99019 United States |
Date of Grant: 07/24/2009 Application Dated: 07/20/2009 |
| Attention: Jay Holcomb , R&D Manager, Regulatory and Programs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EO9100GDLR |
| Name of Grantee: | Itron, Inc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | AMR transceiver device for utility meters. |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 908.0 - 924.0 | 0.143 |
| Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CKC Certification Services, LLC 5046 Sierra Pines Mariposa, CA 95338 |
Date of Grant: 07/24/2009 Application Dated: 07/20/2009 |
| Itron, Inc. |
| 2111 N. Molter Road |
| Liberty Lake, WA 99019 |
| Attention: Jay Holcomb , R&D Manager, Regulatory and Programs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EO9100GDLR |
| Name of Grantee: | Itron, Inc. |
| Equipment Class: | Part 15 Low Power Transceiver, Rx Verified |
| Notes: | AMR transceiver device for utility meters. |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 908.0 - 908.0 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application ahUSeAhDQkpyyaD4FAZa+A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Itron, Inc. 2111 N. Molter Road Liberty Lake, WA 99019 United States |
Date of Grant: 07/24/2009 Application Dated: 07/20/2009 |
| Attention: Jay Holcomb , R&D Manager, Regulatory and Programs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EO9100GDLR |
| Name of Grantee: | Itron, Inc. |
| Equipment Class: | Part 15 Low Power Transceiver, Rx Verified |
| Notes: | AMR transceiver device for utility meters. |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 908.0 - 908.0 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |