FCC ID EO9CCU100

AMR transceiver device for utility meters

by Itron, Inc.

Grantee Code: EO9   Product Code: CCU100
Latest application date: 2016-09-08

Device Images

FCC ID Device Details

FCC IDEO9CCU100
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeEO9
Product CodeCCU100
Applicant BusinessItron, Inc. 🇺🇸
Related Domains itron.com
Equipment ClassAMR transceiver device for utility meters
Test FirmCKC Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
903-926.9 MHzClass II permissive change or modification of presently authorized equipment2016-09-08
903-926.9 MHzClass II permissive change or modification of presently authorized equipment2013-06-13
903-926.8 MHzClass II permissive change or modification of presently authorized equipment2011-04-15
903-926.8 MHzOriginal Equipment2010-10-29
2412-2462 MHzOriginal Equipment2010-10-29

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2016-09-08PDF 5.5 MB
Users ManualUsers Manual2011-04-15PDF 2.1 MB
Users ManualUsers Manual2010-10-29PDF 2.4 MB
Users manualUsers Manual2010-10-29PDF 2.4 MB
All Common 1Internal Photos2010-10-29PDF 5.2 MB
All Common 2Internal Photos2010-10-29PDF 3.7 MB
CCU100Internal Photos2010-10-29PDF 2.8 MB
CCU100 RepeaterInternal Photos2010-10-29PDF 1.9 MB
CCU100RInternal Photos2010-10-29PDF 1.5 MB
CCU100R RepeaterInternal Photos2010-10-29PDF 575.3 KB
Common1Internal Photos2010-10-29PDF 5.2 MB
Common2Internal Photos2010-10-29PDF 3.7 MB
CCU100External Photos2010-10-29PDF 2.9 MB
CCU100 RepeaterExternal Photos2010-10-29PDF 2.9 MB
CCU100RExternal Photos2010-10-29PDF 2.7 MB
CCU100R RepeaterExternal Photos2010-10-29PDF 2.9 MB
ID LabelID Label/Location Info2010-10-29PDF 96.1 KB
Label LocationID Label/Location Info2010-10-29PDF 46.5 KB
Test Setup Photos Part 1Test Setup Photos2011-04-15PDF 135.8 KB
Test Setup Photos Part 2Test Setup Photos2011-04-15PDF 101.5 KB
Test Setup PhotosTest Setup Photos2010-10-29PDF 122.2 KB
Test setup photosTest Setup Photos2010-10-29PDF 152.1 KB
Test ReportTest Report2016-09-08PDF 1.6 MB
Test Report 1Test Report2013-06-13PDF 1.2 MB
test Report 2Test Report2013-06-13PDF 649.9 KB
Original TR Corrected Part 1Test Report2011-04-15PDF 2.9 MB
Original TR Corrected Part 2Test Report2011-04-15PDF 4.5 MB
PC2 ReportTest Report2011-04-15PDF 1.2 MB
Test Report Part 1Test Report2010-10-29PDF 4.9 MB
Test Report Part 1Test Report2010-10-29PDF 4.4 MB
Test Report Part 2Test Report2010-10-29PDF 3.5 MB
Test Report Part 2Test Report2010-10-29PDF 3.1 MB
Cover LetterCover Letter(s)2016-09-08PDF 118.4 KB
TCB NotesCover Letter(s)2016-09-08PDF 59.3 KB
Confidentiality LetterCover Letter(s)2013-06-13PDF 71.1 KB
Cover LetterCover Letter(s)2013-06-13PDF 69.3 KB
Cover letterCover Letter(s)2011-04-15PDF 36 KB
Power ListingCover Letter(s)2011-04-15PDF 32.8 KB
TCB CorrespondenceCover Letter(s)2011-04-15PDF 17.1 KB
Confidentiality RequestCover Letter(s)2010-10-29PDF 300.9 KB
Cover LetterCover Letter(s)2010-10-29PDF 18.9 KB
TCB CorrespondanceCover Letter(s)2010-10-29PDF 59.5 KB
TCB CorrespondenceCover Letter(s)2010-10-29PDF 59.5 KB
RF ExposureRF Exposure Info2016-09-08PDF 1.1 MB
RF ExposureRF Exposure Info2013-06-13PDF 108.8 KB
RF ExposureRF Exposure Info2011-04-15PDF 92.8 KB
MPE ReportRF Exposure Info2010-10-29PDF 101.7 KB
MPE ReportRF Exposure Info2010-10-29PDF 101.6 KB

Application Information

Application IDAaV+4rcLgOmEqvCYGnB+dg==
Final Action Date2016-09-08
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0005861034
ModelCCU100
Frequency Range903-926.9 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionAMR transceiver device for utility meters
Responsible PartyJay R. Holcomb, R&D; Spectrum Regulatory, jay.holcomb@itron.com , 509-891-3281
Test FirmSteve Behm, CKC Laboratories, Inc., steve.behm@ckc.com , 209-966-5240
TCB Emailtcbinfo@ckc.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsC2PC to add antenna. Power listed is conducted. Professional installation required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Certain antennas used with this equipment require a minimum insertion loss, or have output power limitations as documented in the application. Approved for use with antenna(s) as listed in this filing.

Applications

Application IDDatePurpose
AaV+4rcLgOmEqvCYGnB+dg==2016-09-08Class II permissive change or modification of presently authorized equipment
wjKhYBMNRXv1X6XfhOviJg==2013-06-13Class II permissive change or modification of presently authorized equipment
nh7YeNEosaleNhb+oxeeTw==2011-04-15Class II permissive change or modification of presently authorized equipment
xOusgIwMJCqeChWrg/qcCg==2010-10-29Original Equipment
V6emN88tre6UcXEU3akDAA==2010-10-29Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
903-926.9 MHz0.616000015C20
903-926.8 MHz0.616000015C20
903-926.8 MHz0.479000015C20
2412-2462 MHz0.044000015C20

Grants

TCB Grant - Application xOusgIwMJCqeChWrg/qcCg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 10/29/2010

Application Dated: 10/28/2010
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device reading AMR endpoints
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.8 0.479  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application xOusgIwMJCqeChWrg/qcCg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 10/29/2010

Application Dated: 10/28/2010
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device reading AMR endpoints
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.8 0.479  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

TCB Grant - Application wjKhYBMNRXv1X6XfhOviJg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 06/13/2013

Application Dated: 06/05/2013
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for reading utility meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.9 0.616  

C2PC for operational characteristics. Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter procedures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application wjKhYBMNRXv1X6XfhOviJg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 06/13/2013

Application Dated: 06/05/2013
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for reading utility meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.9 0.616  

C2PC for operational characteristics. Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter procedures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

TCB Grant - Application V6emN88tre6UcXEU3akDAA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 10/29/2010

Application Dated: 10/29/2010
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100
Name of Grantee:  Itron, Inc.
Equipment Class: Digital Transmission System
Notes: AMR transceiver device reading AMR endpoints
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2412.0  -  2462.0 0.044  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application V6emN88tre6UcXEU3akDAA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 10/29/2010

Application Dated: 10/29/2010
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100
Name of Grantee:  Itron, Inc.
Equipment Class: Digital Transmission System
Notes: AMR transceiver device reading AMR endpoints
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2412.0  -  2462.0 0.044  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

TCB Grant - Application nh7YeNEosaleNhb+oxeeTw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 04/15/2011

Application Dated: 04/13/2011
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for reading utlity meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.8 0.616  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application nh7YeNEosaleNhb+oxeeTw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 04/15/2011

Application Dated: 04/13/2011
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for reading utlity meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.8 0.616  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

TCB Grant - Application AaV+4rcLgOmEqvCYGnB+dg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 09/08/2016

Application Dated: 08/30/2016
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Spectrum Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for utility meters
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.9 0.616  

C2PC to add antenna. Power listed is conducted. Professional installation required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Certain antennas used with this equipment require a minimum insertion loss, or have output power limitations as documented in the application. Approved for use with antenna(s) as listed in this filing.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application AaV+4rcLgOmEqvCYGnB+dg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 09/08/2016

Application Dated: 08/30/2016
 
Attention: Jay Holcomb , R&D Spectrum Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for utility meters
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.9 0.616  

C2PC to add antenna. Power listed is conducted. Professional installation required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Certain antennas used with this equipment require a minimum insertion loss, or have output power limitations as documented in the application. Approved for use with antenna(s) as listed in this filing.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

Mail To: