FCC ID EO9CCU100TB

AMR transceiver device for utility meters

by Itron, Inc.

Grantee Code: EO9   Product Code: CCU100TB
Latest application date: 2016-09-08

Device Images

FCC ID Device Details

FCC IDEO9CCU100TB
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeEO9
Product CodeCCU100TB
Applicant BusinessItron, Inc. 🇺🇸
Related Domains itron.com
Equipment ClassAMR transceiver device for utility meters
Test FirmCKC Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
903-926.9 MHzClass II permissive change or modification of presently authorized equipment2016-09-08
903-926.9 MHzClass II permissive change or modification of presently authorized equipment2012-11-01
2412-2462 MHzOriginal Equipment2011-10-05
903-926.8 MHzOriginal Equipment2011-10-05

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2016-09-08PDF 5.5 MB
Users ManualUsers Manual2011-10-05PDF 3.6 MB
Internal PhotosInternal Photos2016-09-08PDF 186.9 KB
Internal PhotosInternal Photos2011-10-05PDF 2.9 MB
External PhotosExternal Photos2011-10-05PDF 2.8 MB
ID LabelID Label/Location Info2016-09-08PDF 61.8 KB
ID Label RevisedID Label/Location Info2011-10-05PDF 302.6 KB
Label LocationID Label/Location Info2011-10-05PDF 46.3 KB
Test Setup Photos Metadata onlyTest Setup Photos2016-09-08PDF 349.3 KB
Set Up PhotosTest Setup Photos2011-10-05PDF 281.7 KB
Setup PhotosTest Setup Photos2011-10-05PDF 160.4 KB
Test Report Metadata onlyTest Report2016-09-08PDF 1.6 MB
Test Report 1Test Report2012-11-01PDF 1.1 MB
Test Report 2bTest Report2012-11-01PDF 169.1 KB
Test ReportTest Report2011-10-05PDF 5 MB
Test Report 1Test Report2011-10-05PDF 2.4 MB
Test Report 2Test Report2011-10-05PDF 4.3 MB
Cover LetterCover Letter(s)2016-09-08PDF 119.5 KB
Confidentiality RequestCover Letter(s)2012-11-01PDF 71.2 KB
Cover LetterCover Letter(s)2012-11-01PDF 70.2 KB
Conf. LetterCover Letter(s)2011-10-05PDF 64.7 KB
Conf. RequestCover Letter(s)2011-10-05PDF 64.7 KB
Cover LetterCover Letter(s)2011-10-05PDF 64.6 KB
Prof. Install LetterCover Letter(s)2011-10-05PDF 84.5 KB
Prof. IntsallCover Letter(s)2011-10-05PDF 84.5 KB
RF Exposure InfoRF Exposure Info2016-09-08PDF 1.1 MB
RF exposureRF Exposure Info2012-11-01PDF 123.7 KB
RF ExposureRF Exposure Info2011-10-05PDF 102.2 KB
RF ExposureRF Exposure Info2011-10-05PDF 92.7 KB

Application Information

Application IDAAYv6xII4rDU902ywKCySA==
Final Action Date2016-09-08
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0005861034
ModelCCU100TB
Frequency Range903-926.9 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionAMR transceiver device for utility meters
Responsible PartyJay R. Holcomb, R&D; Spectrum Regulatory, jay.holcomb@itron.com , 509-891-3281
Test FirmSteve Behm, CKC Laboratories, Inc., steve.behm@ckc.com , 209-966-5240
TCB Emailtcbinfo@ckc.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsC2PC for product modification. Power listed is conducted. Professional installation required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing.

Applications

Application IDDatePurpose
AAYv6xII4rDU902ywKCySA==2016-09-08Class II permissive change or modification of presently authorized equipment
XBmXPZqC/1HLajDR1ZqBWQ==2012-11-01Class II permissive change or modification of presently authorized equipment
l+FHNLa6UL95IqLb1yUWtw==2011-10-05Original Equipment
HV+2kdrmoFL23VFbnE8f2g==2011-10-05Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
903-926.9 MHz0.562000015C20
903-926.8 MHz0.562000015C20
2412-2462 MHz0.126000015C20

Grants

TCB Grant - Application XBmXPZqC/1HLajDR1ZqBWQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 11/01/2012

Application Dated: 10/26/2012
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100TB
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for reading utility meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.9 0.562  

C2PC for operational characteristics. Power listed is conducted. Professional installation required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application XBmXPZqC/1HLajDR1ZqBWQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 11/01/2012

Application Dated: 10/26/2012
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100TB
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for reading utility meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.9 0.562  

C2PC for operational characteristics. Power listed is conducted. Professional installation required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

TCB Grant - Application l+FHNLa6UL95IqLb1yUWtw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 10/05/2011

Application Dated: 09/28/2011
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100TB
Name of Grantee:  Itron, Inc.
Equipment Class: Digital Transmission System
Notes: AMR transceiver device for reading utility meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2412.0  -  2462.0 0.126  

Power listed is conducted. Professional installation required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 22 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application l+FHNLa6UL95IqLb1yUWtw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 10/05/2011

Application Dated: 09/28/2011
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100TB
Name of Grantee:  Itron, Inc.
Equipment Class: Digital Transmission System
Notes: AMR transceiver device for reading utility meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2412.0  -  2462.0 0.126  

Power listed is conducted. Professional installation required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 22 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

TCB Grant - Application HV+2kdrmoFL23VFbnE8f2g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 10/05/2011

Application Dated: 09/28/2011
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100TB
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for reading utility meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.8 0.562  

Power listed is conducted. Professional installation required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 22 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application HV+2kdrmoFL23VFbnE8f2g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 10/05/2011

Application Dated: 09/28/2011
 
Attention: Jay Holcomb , R&D Manager, Regulatory and Programs

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100TB
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for reading utility meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.8 0.562  

Power listed is conducted. Professional installation required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 22 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

TCB Grant - Application AAYv6xII4rDU902ywKCySA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 09/08/2016

Application Dated: 08/30/2016
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Spectrum Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100TB
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for utility meters
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.9 0.562  

C2PC for product modification. Power listed is conducted. Professional installation required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application AAYv6xII4rDU902ywKCySA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 09/08/2016

Application Dated: 08/30/2016
 
Attention: Jay Holcomb , R&D Spectrum Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9CCU100TB
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AMR transceiver device for utility meters
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 903.0  -  926.9 0.562  

C2PC for product modification. Power listed is conducted. Professional installation required. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

Mail To: