FCC ID EO9IMRD

Automatic Meter Reading Belt Worn Reader and Programmer

by Itron, Inc.

Grantee Code: EO9   Product Code: IMRD
Latest application date: 2025-01-24

FCC ID Device Details

FCC IDEO9IMRD
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeEO9
Product CodeIMRD
Applicant BusinessItron, Inc. 🇺🇸
Related Domains itron.com
Equipment ClassAutomatic Meter Reading Belt Worn Reader and Programmer
Test FirmCKC Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
904.8-924.4 MHzClass II permissive change or modification of presently authorized equipment2025-01-24
952-959.85 MHzOriginal Equipment2021-11-16
908-924 MHzOriginal Equipment2021-11-16
908-924 MHzOriginal Equipment2021-11-16
952-953 MHzOriginal Equipment2021-11-16

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2021-11-16PDF 790.5 KB
External Photos Metadata onlyInternal Photos2021-11-16PDF 378.1 KB
Internal PhotosInternal Photos2021-11-16PDF 2.5 MB
External PhotosExternal Photos2021-11-16PDF 378.1 KB
ID LabelID Label/Location Info2025-01-24PDF 273.7 KB
ID LabelID Label/Location Info2021-11-16PDF 233.2 KB
ID Label LocationID Label/Location Info2021-11-16PDF 278.9 KB
Test Setup PhotosTest Setup Photos2021-11-16PDF 1.2 MB
Test Setup PhotosTest Setup Photos2021-11-16PDF 1.2 MB
Test Setup PhotosTest Setup Photos2021-11-16PDF 1.4 MB
Test Setup PhotosTest Setup Photos2021-11-16PDF 1.3 MB
Test Report 1Test Report2025-01-24PDF 2.9 MB
Test Report 2Test Report2025-01-24PDF 1.9 MB
Test ReportTest Report2021-11-16PDF 3.9 MB
Test ReportTest Report2021-11-16PDF 2 MB
Test ReportTest Report2021-11-16PDF 2.7 MB
Test ReportTest Report2021-11-16PDF 4.4 MB
Covered List AttestationAttestation Statements2025-01-24PDF 303.6 KB
US Agent for service of process attestationAttestation Statements2025-01-24PDF 143.5 KB
Authorization LetterCover Letter(s)2025-01-24PDF 77.3 KB
Confidentiality RequestCover Letter(s)2025-01-24PDF 246.8 KB
PCII LetterCover Letter(s)2025-01-24PDF 207.4 KB
Confidentiality RequestCover Letter(s)2021-11-16PDF 54.8 KB
Cover LetterCover Letter(s)2021-11-16PDF 54.1 KB
RF Exposure InfoRF Exposure Info2025-01-24PDF 765.5 KB
SAR ReportRF Exposure Info2025-01-24PDF 1.8 MB
Antenna InfoParts List/Tune Up Info2021-11-16PDF 359.1 KB
Block Diagram Metadata onlyBlock DiagramPDF 473.3 KB
Schematics Metadata onlySchematicsPDF 777 KB
Schematics Metadata onlySchematicsPDF 1.2 MB
Operational Description Metadata onlyOperational DescriptionPDF 745.9 KB
Operational Description Metadata onlyOperational DescriptionPDF 543.2 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 548.4 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 864.1 KB
Tune Up Info Metadata onlyParts List/Tune Up InfoPDF 54.4 KB

Application Information

Application IDYQTUE/2BDcNZg4C1W1IBOQ==
Final Action Date2025-01-24
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0005861034
ModelIMRD
Frequency Range904.8-924.4 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionAutomatic Meter Reading Belt Worn Reader and Programmer
Responsible PartyJack McPeck, Senior Product Development Manager, jack.mcpeck@itron.com , 509-924-9900
AgentMichelle Michelle Michelle, CKC Certification Services, LLC, tcbinfo@ckc.com , 209-299-5240
Technical ContactJim Anselmo, Itron, Inc., James.Anselmo@itron.com , 509-891-3408
Non-Technical ContactTim Plass, Itron, Inc., Tim.Plass@itron.com , 509-924-9900
Test FirmSteve Behm, CKC Laboratories, Inc., qa@ckc.com , 209-966-5240
TCB Emailtcbadmin@ckc.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsC2PC to add operational mode. Power listed is conducted. Evaluated for portable RF exposure conditions. Body-worn operating configuration(s) are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing Highest reported SAR values: Body: 1.56 W/kg

Applications

Application IDDatePurpose
YQTUE/2BDcNZg4C1W1IBOQ==2025-01-24Class II permissive change or modification of presently authorized equipment
qI2cCqeNOz355p4rIveeYQ==2021-11-16Original Equipment
USEnGo0jina06X8ieoD3EA==2021-11-16Original Equipment
UF9l86/xbmg4pt6DE53UxA==2021-11-16Original Equipment
F3tQ+nprBQJiUJOpyY7xEA==2021-11-16Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
904.8-924.4 MHz0.63515CCC
908-924 MHz0.996000015CCC
908-924 MHz15CCC
908-924 MHz0.99615CCC
952-953 MHz15.231CC
952-959.85 MHz0.97700000.0000700000%1K28A1D101

Grants

TCB Grant - Application YQTUE/2BDcNZg4C1W1IBOQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 01/24/2025

Application Dated: 01/22/2025
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jack McPeck , Senior Product Development Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9IMRD
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Automatic Meter Reading Belt Worn Reader and Programmer
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.0  -  924.0 0.996  
CC 15C 904.8  -  924.4 0.635  

C2PC to add operational mode.

Power listed is conducted. Evaluated for portable RF exposure conditions. Body-worn operating configuration(s) are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing

Highest reported SAR values: Body: 1.56 W/kg


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application YQTUE/2BDcNZg4C1W1IBOQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 01/24/2025

Application Dated: 01/22/2025
 
Attention: Jack McPeck , Senior Product Development Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9IMRD
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Automatic Meter Reading Belt Worn Reader and Programmer
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.0  -  924.0 0.996  
CC 15C 904.8  -  924.4 0.635  

C2PC to add operational mode.

Power listed is conducted. Evaluated for portable RF exposure conditions. Body-worn operating configuration(s) are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing

Highest reported SAR values: Body: 1.56 W/kg


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application USEnGo0jina06X8ieoD3EA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 11/16/2021

Application Dated: 11/11/2021
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Spectrum Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9IMRD
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Low Power Transceiver, Rx Verified
Notes: Automatic Meter Reading Belt Worn Reader and Programmer
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.0  -  924.0  

Approved for use with antenna(s) as listed in this filing.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application USEnGo0jina06X8ieoD3EA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 11/16/2021

Application Dated: 11/11/2021
 
Attention: Jay Holcomb , R&D Spectrum Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9IMRD
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Low Power Transceiver, Rx Verified
Notes: Automatic Meter Reading Belt Worn Reader and Programmer
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.0  -  924.0  

Approved for use with antenna(s) as listed in this filing.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application UF9l86/xbmg4pt6DE53UxA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 11/16/2021

Application Dated: 11/11/2021
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Spectrum Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9IMRD
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Automatic Meter Reading Belt Worn Reader and Programmer
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.0  -  924.0 0.996  

Power listed is conducted. Evaluated for portable RF exposure conditions. Body-worn operating configuration(s) are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing

Highest reported SAR values: Body: 1.56 W/kg


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application UF9l86/xbmg4pt6DE53UxA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 11/16/2021

Application Dated: 11/11/2021
 
Attention: Jay Holcomb , R&D Spectrum Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9IMRD
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Automatic Meter Reading Belt Worn Reader and Programmer
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.0  -  924.0 0.996  

Power listed is conducted. Evaluated for portable RF exposure conditions. Body-worn operating configuration(s) are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing

Highest reported SAR values: Body: 1.56 W/kg


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application qI2cCqeNOz355p4rIveeYQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 11/16/2021

Application Dated: 11/11/2021
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Spectrum Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9IMRD
Name of Grantee:  Itron, Inc.
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: Automatic Meter Reading Belt Worn Reader and Programmer
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
101 952.0  -  959.85 0.977 0.00007  % 1K28A1D

Power listed is EIRP. Evaluated for portable RF exposure conditions. Body-worn operating configuration(s) are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing

Highest reported SAR values: Body: 1.56 W/kg


EAS Grant - Application qI2cCqeNOz355p4rIveeYQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 11/16/2021

Application Dated: 11/11/2021
 
Attention: Jay Holcomb , R&D Spectrum Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9IMRD
Name of Grantee:  Itron, Inc.
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: Automatic Meter Reading Belt Worn Reader and Programmer
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
101 952.0  -  959.85 0.977 0.00007  % 1K28A1D

Power listed is EIRP. Evaluated for portable RF exposure conditions. Body-worn operating configuration(s) are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing

Highest reported SAR values: Body: 1.56 W/kg



TCB Grant - Application F3tQ+nprBQJiUJOpyY7xEA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CKC Certification Services, LLC
5046 Sierra Pines
Mariposa, CA 95338
Date of Grant: 11/16/2021

Application Dated: 11/11/2021
Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
 
Attention: Jay Holcomb , R&D Spectrum Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9IMRD
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Security/Remote Control Transmitter
Notes: Automatic Meter Reading Belt Worn Reader and Programmer
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15.231 952.0  -  953.0  

Approved for use with antenna(s) as listed in this filing.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application F3tQ+nprBQJiUJOpyY7xEA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron, Inc.
2111 N. Molter Road
Liberty Lake, WA 99019
United States
  Date of Grant: 11/16/2021

Application Dated: 11/11/2021
 
Attention: Jay Holcomb , R&D Spectrum Regulatory

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EO9IMRD
Name of Grantee:  Itron, Inc.
Equipment Class: Part 15 Security/Remote Control Transmitter
Notes: Automatic Meter Reading Belt Worn Reader and Programmer
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15.231 952.0  -  953.0  

Approved for use with antenna(s) as listed in this filing.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: