FCC ID EP9TMXHRM
heart rate monitor
by Timex Group USA, Inc.
Grantee Code: EP9 Product Code: TMXHRM
Latest application date: 1999-07-19
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 0.129-0.141 MHz | Original Equipment | 1999-07-19 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Statement from Timex Corporation | Users Manual | 1999-07-19 | PDF 36.3 KB |
| Certification Photographs | External Photos | 1999-07-19 | PDF 335.5 KB |
| Label and label location | ID Label/Location Info | 1999-07-19 | PDF 166.9 KB |
| Block Diagram | Block Diagram | 1999-07-19 | PDF 38.6 KB |
| Schematics 3 pages | Schematics | 1999-07-19 | PDF 240.2 KB |
| Product Description | Operational Description | 1999-07-19 | PDF 95 KB |
| Configuration Photos | Test Setup Photos | 1999-07-19 | PDF 193.5 KB |
| Test Report | Test Report | 1999-07-19 | PDF 400 KB |
Application Information
| Application ID | 3AaxkGXq0/aaWw2DiN6fuQ== |
|---|---|
| Final Action Date | 1999-07-19 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0023039423 |
| Model | TMXHRM |
| Frequency Range | 0.129-0.141 MHz |
| Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz |
| Device Description | heart rate monitor |
| Responsible Party | Sam Everett, Quality Regulatory Engineer, severett@timexgroup.com |
| Agent | Andrew Andrew Andrew, Intertek Testing Services NA Inc., ajb@itsqs.com |
| Technical Contact | Andrew J Bellezza, Intertek Testing Services NA Inc., ajb@itsqs.com |
| Non-Technical Contact | Jody K Zarnowiec, Intertek Testing Services NA Inc., jkz@itsqs.com |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 3AaxkGXq0/aaWw2DiN6fuQ== | 1999-07-19 | Original Equipment |
Grants
TCB Grant - Application 3AaxkGXq0/aaWw2DiN6fuQ==
This application does not exist.
EAS Grant - Application 3AaxkGXq0/aaWw2DiN6fuQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Timex Group USA, Inc. 555 Christian Road P.O. Box 310, Middlebury, CT 06762-0310 United States |
Date of Grant: 07/19/1999 Application Dated: 05/05/1999 |
| Attention: Sam Everett , Quality Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EP9TMXHRM |
| Name of Grantee: | Timex Group USA, Inc. |
| Equipment Class: | Part 15 Low Power Transmitter Below 1705 kHz |
| Notes: | heart rate monitor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 37 | 15C | 0.129 - 0.141 |
| 37: | This device has shown compliance with new rules adopted under Docket 87-389 and is not affected by Section 15.37, transition rule. |
| Mail To: |
| Ronald J. DeRosa, Senior Project Engineer |
| Timex Corporation |
| 310Park Road Extension |
| Middlebury, CT 06762-0310 |