FCC ID EW780-7029-01
1.9GHz BABY MONITOR- PARENT UNIT
by VTech Telecommunications Ltd
Grantee Code: EW7 Product Code: 80702901
Latest application date: 2009-05-12
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1921.536-1928.448 MHz | Original Equipment | 2009-05-12 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2009-05-12 | PDF 756.9 KB |
| Internal Photos | Internal Photos | 2009-05-12 | PDF 619.8 KB |
| External Photos | External Photos | 2009-05-12 | PDF 78.7 KB |
| Label | ID Label/Location Info | 2009-05-12 | PDF 299.1 KB |
| Test Setup Photos | Test Setup Photos | 2009-05-12 | PDF 120.9 KB |
| Conduct | Test Report | 2009-05-12 | PDF 29.7 KB |
| Inband | Test Report | 2009-05-12 | PDF 44.3 KB |
| Test Report | Test Report | 2009-05-12 | PDF 185.5 KB |
| bw | Test Report | 2009-05-12 | PDF 49.1 KB |
| peaktp | Test Report | 2009-05-12 | PDF 40.4 KB |
| psd | Test Report | 2009-05-12 | PDF 42.2 KB |
| UTAM | Attestation Statements | 2009-05-12 | PDF 48.3 KB |
| Agency Letter | Cover Letter(s) | 2009-05-12 | PDF 97.7 KB |
| Confidential Request | Cover Letter(s) | 2009-05-12 | PDF 30.1 KB |
| Declaration Letter | Cover Letter(s) | 2009-05-12 | PDF 27.7 KB |
| SAR Report | RF Exposure Info | 2009-05-12 | PDF 1.2 MB |
Application Information
| Application ID | Fdkn/An6qylTHTL2LkERew== |
|---|---|
| Final Action Date | 2009-05-12 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0015973951 |
| Model | 80-7029-01 |
| Frequency Range | 1921.536-1928.448 MHz |
| Equipment Class | PUT - Part 15 Unlicensed PCS portable Tx worn on body |
| Device Description | 1.9GHz BABY MONITOR- PARENT UNIT |
| Responsible Party | Michael Tsui, Approbation Supervisor, michael_tsui@vtech.com |
| Test Firm | Daniel Yau, Intertek Testing Services Hong Kong Ltd., daniel.yau@intertek.com |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | A3: Unlicensed Personal Communication System (PCS) devices |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | Output is conducted. Device must not be co-located or operating in conjunction with any other antenna or transmitter. This device must transmit with a source-based time-averaging duty factor as described in this filing. Device has been tested for SAR compliance for body-worn configurations. SAR compliance for body-worn operating configurations is limited to the specific belt clip tested for this filing. End-users must be informed of the operating requirements for satisfying body-worn RF exposure compliance. The highest reported SAR value is: Body 0.016 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| Fdkn/An6qylTHTL2LkERew== | 2009-05-12 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 1921.536-1928.448 MHz | 0.1010000 | 15D |
Grants
TCB Grant - Application Fdkn/An6qylTHTL2LkERew==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 <BR>P.O. Box 370, Newberry, FL 32669 |
Date of Grant: 05/12/2009 Application Dated: 05/08/2009 |
| VTech Telecommunications Ltd |
| 23/F Tai Ping Ind Center Block 1 |
| 57 Ting Kok Rd |
| Tai Po NT, Hong Kong |
| Attention: Michael Tsui , Approbation Supervisor |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EW780-7029-01 |
| Name of Grantee: | VTech Telecommunications Ltd |
| Equipment Class: | Part 15 Unlicensed PCS portable Tx worn on body |
| Notes: | 1.9GHz BABY MONITOR- PARENT UNIT |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15D | 1921.536 - 1928.448 | 0.101 |
| Output is conducted. Device must not be co-located or operating in conjunction with any other antenna or transmitter. This device must transmit with a source-based time-averaging duty factor as described in this filing. Device has been tested for SAR compliance for body-worn configurations. SAR compliance for body-worn operating configurations is limited to the specific belt clip tested for this filing. End-users must be informed of the operating requirements for satisfying body-worn RF exposure compliance. The highest reported SAR value is: Body 0.016 W/kg.
|
EAS Grant - Application Fdkn/An6qylTHTL2LkERew==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
VTech Telecommunications Ltd 23/F Tai Ping Ind Center Block 1 57 Ting Kok Rd Tai Po NT, Hong Kong |
Date of Grant: 05/12/2009 Application Dated: 05/08/2009 |
| Attention: Michael Tsui , Approbation Supervisor |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EW780-7029-01 |
| Name of Grantee: | VTech Telecommunications Ltd |
| Equipment Class: | Part 15 Unlicensed PCS portable Tx worn on body |
| Notes: | 1.9GHz BABY MONITOR- PARENT UNIT |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15D | 1921.536 - 1928.448 | 0.101 |
| Output is conducted. Device must not be co-located or operating in conjunction with any other antenna or transmitter. This device must transmit with a source-based time-averaging duty factor as described in this filing. Device has been tested for SAR compliance for body-worn configurations. SAR compliance for body-worn operating configurations is limited to the specific belt clip tested for this filing. End-users must be informed of the operating requirements for satisfying body-worn RF exposure compliance. The highest reported SAR value is: Body 0.016 W/kg.
|