FCC ID EWQ100GTB

RF based meter data collection module

by Itron Inc

Grantee Code: EWQ   Product Code: 100GTB
Latest application date: 2024-08-22

FCC ID Device Details

FCC IDEWQ100GTB
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeEWQ
Product Code100GTB
Applicant BusinessItron Inc 🇺🇸
Related Domains itron.com
Equipment ClassRF based meter data collection module
Test FirmMiCOM Labs

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
903-926.8 MHzOriginal Equipment2024-08-22
908-923.8 MHzOriginal Equipment2024-08-22

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2025-02-18PDF 4.3 MB
Internal PhotosInternal Photos2025-02-18PDF 813.5 KB
External PhotosExternal Photos2025-02-18PDF 1.2 MB
LabelID Label/Location Info2024-08-22PDF 1.2 MB
T Setup photosTest Setup Photos2025-02-18PDF 1.1 MB
AntennaDatasheetTest Report2024-08-22PDF 115.4 KB
Test ReportTest Report2024-08-22PDF 1,008.7 KB
Test ReportTest Report2024-08-22PDF 3.6 MB
2.911_(d)(5)(i) Certification Equipment Type v1Attestation Statements2024-08-22PDF 104.6 KB
2.911_(d)(5)(ii) Certification Applicant v1Attestation Statements2024-08-22PDF 96.3 KB
US Rep Of Service ProcessAttestation Statements2024-08-22PDF 44.9 KB
AntennaDatasheetCover Letter(s)2024-08-22PDF 115.4 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2024-08-22PDF 44.8 KB
Letter of Authorization Rev 1.0Cover Letter(s)2024-08-22PDF 25.2 KB
Letter of Authorization Rev1.0Cover Letter(s)2024-08-22PDF 25.2 KB
Model difference declaration letterCover Letter(s)2024-08-22PDF 53.2 KB
ModeldifferencestatementCover Letter(s)2024-08-22PDF 53.2 KB
MPERF Exposure Info2024-08-22PDF 300 KB
Blocking Metadata onlyBlock DiagramPDF 80.2 KB
SCH Metadata onlySchematicsPDF 931.6 KB
OP Metadata onlyOperational DescriptionPDF 1,023.6 KB
BOM1 Metadata onlyParts List/Tune Up InfoPDF 957.2 KB
BOM2 Metadata onlyParts List/Tune Up InfoPDF 944.7 KB

Application Information

Application IDSEX6KNiOYq9BDkZAkDNPkw==
Final Action Date2024-08-22
Application PurposeOriginal Equipment
Applicant FRN0005861034
Model100GTB
Frequency Range903-926.8 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionRF based meter data collection module
Responsible PartyDan Bomsta, Senior Principal Regulatory Engineer, dan.bomsta@itron.com , 507-781-4480
Technical ContactItron Inc, dan.bomsta@itron.com
Test FirmGordon Hurst, MiCOM Labs, gordon_hurst@micomlabs.com , 925-462-0304
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date02/18/2025
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power.The antenna used with this transmitter must be installed to provide a minimum separation distance of at least20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
SEX6KNiOYq9BDkZAkDNPkw==2024-08-22Original Equipment
Hbwil4qnOCCbZ6xQm4Ecfw==2024-08-22Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
903-926.8 MHz0.262000015CCC
908-923.8 MHz91.400000015CCC

Grants

TCB Grant - Application SEX6KNiOYq9BDkZAkDNPkw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/22/2024

Application Dated: 08/22/2024
Itron Inc
2401 N State Street
Waseca, MN 56093
 
Attention: Dan Bomsta , Senior Principal Regulatory Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EWQ100GTB
Name of Grantee:  Itron Inc
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: RF based meter data collection module
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 903.0  -  926.8 0.262  

Output power listed is conducted power.The antenna used with this transmitter must be installed to provide a minimum separation distance of at least20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application SEX6KNiOYq9BDkZAkDNPkw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Inc
2401 N State Street
Waseca, MN 56093
United States
  Date of Grant: 08/22/2024

Application Dated: 08/22/2024
 
Attention: Dan Bomsta , Senior Principal Regulatory Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EWQ100GTB
Name of Grantee:  Itron Inc
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: RF based meter data collection module
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 903.0  -  926.8 0.262  

Output power listed is conducted power.The antenna used with this transmitter must be installed to provide a minimum separation distance of at least20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application Hbwil4qnOCCbZ6xQm4Ecfw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/22/2024

Application Dated: 08/22/2024
Itron Inc
2401 N State Street
Waseca, MN 56093
 
Attention: Dan Bomsta , Senior Principal Regulatory Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EWQ100GTB
Name of Grantee:  Itron Inc
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: RF based meter data collection module
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.0  -  923.8 91.4  

The antenna used with this transmitter must be installed to provide a minimum separation distance of at least20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application Hbwil4qnOCCbZ6xQm4Ecfw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Inc
2401 N State Street
Waseca, MN 56093
United States
  Date of Grant: 08/22/2024

Application Dated: 08/22/2024
 
Attention: Dan Bomsta , Senior Principal Regulatory Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EWQ100GTB
Name of Grantee:  Itron Inc
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: RF based meter data collection module
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 908.0  -  923.8 91.4  

The antenna used with this transmitter must be installed to provide a minimum separation distance of at least20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: