FCC ID F5302CL3050

Alarm System Wireless Communicator

by Tyco Safety Products Canada Ltd.

Grantee Code: F53   Product Code: 02CL3050
Latest application date: 2002-09-13

FCC ID Device Details

FCC IDF5302CL3050
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeF53
Product Code02CL3050
Applicant BusinessTyco Safety Products Canada Ltd. 🇨🇦
Related Domains tycoint.com
Equipment ClassAlarm System Wireless Communicator
Test FirmNemko Canada Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.01-848.97 MHzChange in identification of presently authorized equipment. Original FCC ID: APV09001 Grant Date: 05/01/20012002-09-13

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2002-09-13PDF 521.7 KB
Internal PhotosInternal Photos2002-09-13PDF 3.3 MB
External PhotosExternal Photos2002-09-13PDF 749.2 KB
Label InformationID Label/Location Info2002-09-13PDF 74.4 KB
Operational Description Metadata onlyOperational Description2002-09-13PDF 46.7 KB
Revised operational descriptionOperational Description2002-09-13PDF 52.2 KB
Test Setup PhotosTest Setup Photos2002-09-13PDF 45.7 KB
Test reportTest Report2002-09-13PDF 109.3 KB
Confidentaility RequestCover Letter(s)2002-09-13PDF 76.1 KB
Response to TCB findingsCover Letter(s)2002-09-13PDF 40.2 KB
Standard ML AuthorizationCover Letter(s)2002-09-13PDF 40.7 KB
Parts ListParts List/Tune Up Info2002-09-13PDF 14.2 KB
Block Diagram Metadata onlyBlock DiagramPDF 38.2 KB
Schematics Metadata onlySchematicsPDF 131 KB

Application Information

Application ID95juFTgUJmWxc1CLuoaxYw==
Final Action Date2002-09-13
Application PurposeChange in identification of presently authorized equipment. Original FCC ID: APV09001 Grant Date: 05/01/2001
Applicant FRN0006834485
Model02CL3050
Frequency Range824.01-848.97 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionAlarm System Wireless Communicator
Responsible PartyDan Nita, Approvals Manager, dnita@tycoint.com , 1-647-480-0430
Test FirmStuart Beck, Nemko Canada Inc., stuart.beck@nemko.com , 613-737-9680
TCB Emailcertification@curtis-straus.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is ERP. Grant Conditions – The antenna used for this transmitter is to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power at each antenna must satisfy the MPE Categorical Exclusion Requirements of §2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

Applications

Application IDDatePurpose
95juFTgUJmWxc1CLuoaxYw==2002-09-13Change in identification of presently authorized equipment. Original FCC ID: APV09001 Grant Date: 05/01/2001

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.01-848.97 MHz0.37200002.5000000000ppm36K0F1D22

Grants

TCB Grant - Application 95juFTgUJmWxc1CLuoaxYw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 09/13/2002

Application Dated: 09/13/2002
Tyco Safety Products Canada Ltd.
3301 Langstaff Road
Concord, Ontario, L4K 4L2
Canada
 
Attention: Dan Nita , Approvals Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F5302CL3050
Name of Grantee:  Tyco Safety Products Canada Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Alarm System Wireless Communicator
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22 824.01  -  848.97 0.372 2.5  PM 36K0F1D

Output power is ERP.

Grant Conditions – The antenna used for this transmitter is to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power at each antenna must satisfy the MPE Categorical Exclusion Requirements of §2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).


EAS Grant - Application 95juFTgUJmWxc1CLuoaxYw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Tyco Safety Products Canada Ltd.
3301 Langstaff Road
Concord, Ontario, L4K 4L2
Canada
  Date of Grant: 09/13/2002

Application Dated: 09/13/2002
 
Attention: Dan Nita , Approvals Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F5302CL3050
Name of Grantee:  Tyco Safety Products Canada Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Alarm System Wireless Communicator
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22 824.01  -  848.97 0.372 2.5  PM 36K0F1D

Output power is ERP.

Grant Conditions – The antenna used for this transmitter is to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power at each antenna must satisfy the MPE Categorical Exclusion Requirements of §2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).



Mail To: