FCC ID F53123G260R

Dual Alarm Communicator

by Tyco Safety Products Canada Ltd.

Grantee Code: F53   Product Code: 123G260R
Latest application date: 2014-04-03

FCC ID Device Details

FCC IDF53123G260R
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeF53
Product Code123G260R
Applicant BusinessTyco Safety Products Canada Ltd. 🇨🇦
Related Domains tycoint.com
Equipment ClassDual Alarm Communicator
Test FirmCETECOM Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzClass II permissive change or modification of presently authorized equipment2014-04-03
824.2-848.8 MHzOriginal Equipment2012-05-04

Exhibits

DocumentTypeAvailableFile
USERS GUIDEUsers Manual2012-05-04PDF 1.5 MB
USERS MANUALUsers Manual2012-05-04PDF 973.4 KB
INTERNAL PHOTOS 1Internal Photos2012-05-04PDF 309.6 KB
INTERNAL PHOTOS 2Internal Photos2012-05-04PDF 804.6 KB
EXTERNAL PHOTOS 1External Photos2012-05-04PDF 199.8 KB
EXTERNAL PHOTOS 2External Photos2012-05-04PDF 196.1 KB
Label and Label LocationID Label/Location Info2014-04-03PDF 1.3 MB
LABELID Label/Location Info2012-05-04PDF 939.6 KB
TEST SETUP PHOTOSTest Setup Photos2012-05-04PDF 204.6 KB
ANTENNA SPECSTest Report2012-05-04PDF 564.2 KB
DECLARATION OF VALIDITY OF MODULE TEST REPORTCover Letter(s)2012-05-04PDF 15.2 KB
TEST REPORT 1Test Report2012-05-04PDF 3.8 MB
TEST REPORT 2Test Report2012-05-04PDF 3.4 MB
TEST REPORT 3Test Report2012-05-04PDF 3.7 MB
WWANTest Report2012-05-04PDF 1 MB
Cover lettersCover Letter(s)2014-04-03PDF 26.9 KB
AGENCY POACover Letter(s)2012-05-04PDF 18.8 KB
CONFIDENTIAL REQUEST LETTERCover Letter(s)2012-05-04PDF 342.3 KB
MODEL EQUALITY DECLARATIONCover Letter(s)2012-05-04PDF 26.9 KB
MODULAR APPROVAL LETTERCover Letter(s)2012-05-04PDF 186.4 KB
MPERF Exposure Info2012-05-04PDF 272.9 KB

Application Information

Application IDU/3m8wd3+OWtoI8rFarVsw==
Final Action Date2014-04-03
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0006834485
Model123G260R
Frequency Range824.2-848.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionDual Alarm Communicator
Responsible PartyDan Nita, Approvals Manager, dnita@tycoint.com , 1-647-480-0430
Test FirmKevin Wang, CETECOM Inc., kevin.wang@cetecom.com , 408-586-6271
TCB EmailStuart.Beck@nemko.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentLimited Single Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsLimited Single Modular Approval. This communicator can only be used in conjunction with this DSC model of alarm panels: PC1864, PC1832, PC1616, HS2128, HS2064, HS2032, HS2016 and it cannot be used with any other hosts. Power output is ERP for this Part 22 and EIRP for Part 24. The antenna installation and operating configurations of this device, including any applicable source-based time averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains 900/1800 MHz GSM functions that are not operational in U.S. Territories.

Applications

Application IDDatePurpose
U/3m8wd3+OWtoI8rFarVsw==2014-04-03Class II permissive change or modification of presently authorized equipment
IUo6SmDdHP0MiSRweyR2mA==2012-05-04Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz2.551Hz245KGXW22H
824.2-848.8 MHz1.3354Hz251KG7W22H
826.2-846.6 MHz0.81329Hz4M07F9W22H
1850.2-1909.8 MHz1.23648Hz245KGXW24E
1850.2-1909.8 MHz1.32167Hz243KG7W24E
1852.4-1907.6 MHz0.75720Hz4M07F9W24E

Grants

TCB Grant - Application U/3m8wd3+OWtoI8rFarVsw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 04/03/2014

Application Dated: 04/03/2014
Tyco Safety Products Canada Ltd.
3301 Langstaff Road
Concord, Ontario, L4K 4L2
Canada
 
Attention: Dan Nita , Approvals Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F53123G260R
Name of Grantee:  Tyco Safety Products Canada Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: Dual Alarm Communicator
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 2.5 51.0  Hz 245KGXW
22H 824.2  -  848.8 1.33 54.0  Hz 251KG7W
22H 826.2  -  846.6 0.813 29.0  Hz 4M07F9W
24E 1850.2  -  1909.8 1.236 48.0  Hz 245KGXW
24E 1850.2  -  1909.8 1.321 67.0  Hz 243KG7W
24E 1852.4  -  1907.6 0.757 20.0  Hz 4M07F9W

Limited Single Modular Approval. This communicator can only be used in conjunction with this DSC model of alarm panels: PC1864, PC1832, PC1616, HS2128, HS2064, HS2032, HS2016 and it cannot be used with any other hosts. Power output is ERP for this Part 22 and EIRP for Part 24. The antenna installation and operating configurations of this device, including any applicable source-based time averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains 900/1800 MHz GSM functions that are not operational in U.S. Territories.

EAS Grant - Application U/3m8wd3+OWtoI8rFarVsw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Tyco Safety Products Canada Ltd.
3301 Langstaff Road
Concord, Ontario, L4K 4L2
Canada
  Date of Grant: 04/03/2014

Application Dated: 04/03/2014
 
Attention: Dan Nita , Approvals Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F53123G260R
Name of Grantee:  Tyco Safety Products Canada Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: Dual Alarm Communicator
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 2.5 51.0  Hz 245KGXW
22H 824.2  -  848.8 1.33 54.0  Hz 251KG7W
22H 826.2  -  846.6 0.813 29.0  Hz 4M07F9W
24E 1850.2  -  1909.8 1.236 48.0  Hz 245KGXW
24E 1850.2  -  1909.8 1.321 67.0  Hz 243KG7W
24E 1852.4  -  1907.6 0.757 20.0  Hz 4M07F9W

Limited Single Modular Approval. This communicator can only be used in conjunction with this DSC model of alarm panels: PC1864, PC1832, PC1616, HS2128, HS2064, HS2032, HS2016 and it cannot be used with any other hosts. Power output is ERP for this Part 22 and EIRP for Part 24. The antenna installation and operating configurations of this device, including any applicable source-based time averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains 900/1800 MHz GSM functions that are not operational in U.S. Territories.



TCB Grant - Application IUo6SmDdHP0MiSRweyR2mA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 05/04/2012

Application Dated: 05/04/2012
Digital Security Controls Ltd.
3301 Langstaff Road
Concord, Ontario, L4K 4L2
Canada
 
Attention: Dan Nita , Approvals Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F53123G260R
Name of Grantee:  Digital Security Controls Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: DUAL ALARM COMMUNICATOR
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 2.5 51.0  Hz 245KGXW
22H 824.2  -  848.8 1.33 54.0  Hz 251KG7W
22H 826.2  -  846.6 0.813 29.0  Hz 4M07F9W
24E 1850.2  -  1909.8 1.236 48.0  Hz 245KGXW
24E 1850.2  -  1909.8 1.321 67.0  Hz 243KG7W
24E 1852.4  -  1907.6 0.757 20.0  Hz 4M07F9W

Limited Single Modular Approval. This communicator can only be used in conjunction with this DSC model of alarm panels: PC1864, PC1832, PC1616 and it cannot be used with any other hosts. Power output is ERP for this Part 22 and EIRP for Part 24. The antenna installation and operating configurations of this device, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains 900/1800 MHz GSM functions that are not operational in U.S. Territories.

EAS Grant - Application IUo6SmDdHP0MiSRweyR2mA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Digital Security Controls Ltd.
3301 Langstaff Road
Concord, Ontario, L4K 4L2
Canada
  Date of Grant: 05/04/2012

Application Dated: 05/04/2012
 
Attention: Dan Nita , Approvals Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F53123G260R
Name of Grantee:  Digital Security Controls Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: DUAL ALARM COMMUNICATOR
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 2.5 51.0  Hz 245KGXW
22H 824.2  -  848.8 1.33 54.0  Hz 251KG7W
22H 826.2  -  846.6 0.813 29.0  Hz 4M07F9W
24E 1850.2  -  1909.8 1.236 48.0  Hz 245KGXW
24E 1850.2  -  1909.8 1.321 67.0  Hz 243KG7W
24E 1852.4  -  1907.6 0.757 20.0  Hz 4M07F9W

Limited Single Modular Approval. This communicator can only be used in conjunction with this DSC model of alarm panels: PC1864, PC1832, PC1616 and it cannot be used with any other hosts. Power output is ERP for this Part 22 and EIRP for Part 24. The antenna installation and operating configurations of this device, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains 900/1800 MHz GSM functions that are not operational in U.S. Territories.



Mail To: