FCC ID F8I-DCXSMR1A

Digivance® CXD SMR 800/900 MHz System)

by ADC Telecommunications Inc

Grantee Code: F8I   Product Code: DCXSMR1A
Latest application date: 2005-12-28

FCC ID Device Details

FCC IDF8I-DCXSMR1A
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeF8I
Product CodeDCXSMR1A
Applicant BusinessADC Telecommunications Inc 🇺🇸
Related Domains commscope.com
Equipment ClassDigivance® CXD SMR 800/900 MHz System)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
851-866 MHzOriginal Equipment2005-12-28

Exhibits

DocumentTypeAvailableFile
manualUsers Manual2005-12-28PDF 1.1 MB
Internal photosInternal Photos2005-12-28PDF 2.9 MB
External photosExternal Photos2005-12-28PDF 2 MB
FCC ID labelID Label/Location Info2005-12-28PDF 208.9 KB
Test reportTest Report2005-12-28PDF 2.8 MB
Attestation statementsCover Letter(s)2005-12-28PDF 60.4 KB
ATCB commentsCover Letter(s)2005-12-28PDF 46.6 KB
ATCB comments SupplementalCover Letter(s)2005-12-28PDF 49 KB
Request Confidentiality 2Cover Letter(s)2005-12-28PDF 99.4 KB
Request for confidentialityCover Letter(s)2005-12-28PDF 48.9 KB
Request for confidentiality 3Cover Letter(s)2005-12-28PDF 31.9 KB
Response to ATCBCover Letter(s)2005-12-28PDF 23.6 KB
MPERF Exposure Info2005-12-28PDF 29.8 KB

Application Information

Application ID02LM8SrSEgIVIeNU57Nr2A==
Final Action Date2005-12-28
Application PurposeOriginal Equipment
Applicant FRN0008274896
ModelDCXSMR1A
Frequency Range851-866 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionDigivance® CXD SMR 800/900 MHz System)
Responsible PartyJoshua Wittman, Compliance Engineer, Joshua.Wittman@commscope.com , 952-403-8322
AgentJoel Joel Joel, TÜV America Inc, jschneider@tuvam.com
Technical ContactJoel Schneider, TUV America Inc, jschneider@tuvam.com
TCB Emailhotline@atcb.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed for this repeater is composite at the antenna connector. To comply with rf exposure requirements, the maximum composite power output from the antenna may not exceed 1000 watts EIRP and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 6m from all persons. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
02LM8SrSEgIVIeNU57Nr2A==2005-12-28Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
851-866 MHz7.71AmpF3E9
851-866 MHz5.71AmpD7W9
851-866 MHz5.62AmpF9W9
935-940 MHz7.19AmpF3E9
935-940 MHz8.07AmpD7W9
935-940 MHz7.36AmpF9W9

Grants

TCB Grant - Application 02LM8SrSEgIVIeNU57Nr2A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 12/28/2005

Application Dated: 12/28/2005
ADC Telecommunications Inc
501 Shenandoah Drive
Shakopee, MN 55379
 
Attention: Joshua Wittman , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F8I-DCXSMR1A
Name of Grantee:  ADC Telecommunications Inc
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Digivance® CXD SMR 800/900 MHz System)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 851.0  -  866.0 7.71  Amp F3E
90 851.0  -  866.0 5.71  Amp D7W
90 851.0  -  866.0 5.62  Amp F9W
90 935.0  -  940.0 7.19  Amp F3E
90 935.0  -  940.0 8.07  Amp D7W
90 935.0  -  940.0 7.36  Amp F9W

Power output listed for this repeater is composite at the antenna connector. To comply with rf exposure requirements, the maximum composite power output from the antenna may not exceed 1000 watts EIRP and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 6m from all persons. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application 02LM8SrSEgIVIeNU57Nr2A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ADC Telecommunications Inc
501 Shenandoah Drive
Shakopee, MN 55379
United States
  Date of Grant: 12/28/2005

Application Dated: 12/28/2005
 
Attention: Joshua Wittman , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F8I-DCXSMR1A
Name of Grantee:  ADC Telecommunications Inc
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Digivance® CXD SMR 800/900 MHz System)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 851.0  -  866.0 7.71  Amp F3E
90 851.0  -  866.0 5.71  Amp D7W
90 851.0  -  866.0 5.62  Amp F9W
90 935.0  -  940.0 7.19  Amp F3E
90 935.0  -  940.0 8.07  Amp D7W
90 935.0  -  940.0 7.36  Amp F9W

Power output listed for this repeater is composite at the antenna connector. To comply with rf exposure requirements, the maximum composite power output from the antenna may not exceed 1000 watts EIRP and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 6m from all persons. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.