FCC ID F8I-DIS190AB
Digivance 1900 MHz Indoor Coverage Solution
by ADC Telecommunications Inc
Grantee Code: F8I Product Code: DIS190AB
Latest application date: 2006-10-29
FCC ID Device Details
| FCC ID | F8I-DIS190AB |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | F8I |
| Product Code | DIS190AB |
| Applicant Business | ADC Telecommunications Inc 🇺🇸 |
| Related Domains | |
| Equipment Class | Digivance 1900 MHz Indoor Coverage Solution |
| Test Firm | TUV SUD America - Product Service |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1930-1990 MHz | Original Equipment | 2006-10-29 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual Section 1 | Users Manual | 2006-10-29 | PDF 2.2 MB |
| Users Manual Section 2 | Users Manual | 2006-10-29 | PDF 2.6 MB |
| Users Manual Section 3 | Users Manual | 2006-10-29 | PDF 2.6 MB |
| Internal Photos | Internal Photos | 2006-10-29 | PDF 792.5 KB |
| External Photos | External Photos | 2006-10-29 | PDF 941 KB |
| Label Location | ID Label/Location Info | 2006-10-29 | PDF 182.5 KB |
| Part 15 Label on the Host | ID Label/Location Info | 2006-10-29 | PDF 130.5 KB |
| Sample Label Revised | ID Label/Location Info | 2006-10-29 | PDF 21.2 KB |
| Block Diagram | Block Diagram | 2006-10-29 | PDF 15.5 KB |
| Test Report Part 1 Revised | Test Report | 2006-10-29 | PDF 2.7 MB |
| Test Report Part 2 Revised | Test Report | 2006-10-29 | PDF 2.7 MB |
| Comments and Response | Cover Letter(s) | 2006-10-29 | PDF 73.6 KB |
| Confidentiality Letter | Cover Letter(s) | 2006-10-29 | PDF 26.7 KB |
| RF Exposure Information | RF Exposure Info | 2006-10-29 | PDF 44 KB |
| Tune Up Procedure | Parts List/Tune Up Info | 2006-10-29 | PDF 18.3 KB |
| UM Page with RF exposure Info | RF Exposure Info | 2006-10-29 | PDF 37.1 KB |
| Schematics Metadata only | Schematics | PDF 445.6 KB | |
| Theory of Operation Metadata only | Operational Description | PDF 16.6 KB | |
| DRU Parts List Metadata only | Parts List/Tune Up Info | PDF 36.4 KB | |
| DRU Top Level Parts List Metadata only | Parts List/Tune Up Info | PDF 8.5 KB |
Application Information
| Application ID | zRiX107EkTQPbyYP9OCEvA== |
|---|---|
| Final Action Date | 2006-10-29 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0008274896 |
| Model | DIS190AB |
| Frequency Range | 1930-1990 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Digivance 1900 MHz Indoor Coverage Solution |
| Responsible Party | Joshua Wittman, Compliance Engineer, Joshua.Wittman@commscope.com |
| Technical Contact | Mark Miska, ADC Telecommunications Inc., mark.miska@adc.com |
| Test Firm | Joel Schneider, TUV SUD America - Product Service, jschneider@tuvam.com |
| TCB Email | hotline@ATCB.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output is conducted for a single carrier. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| zRiX107EkTQPbyYP9OCEvA== | 2006-10-29 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application zRiX107EkTQPbyYP9OCEvA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 10/29/2006 Application Dated: 10/27/2006 |
| ADC Telecommunications Inc |
| 501 Shenandoah Drive |
| Shakopee, MN 55379 |
| Attention: Joshua Wittman , Compliance Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | F8I-DIS190AB |
| Name of Grantee: | ADC Telecommunications Inc |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Digivance 1900 MHz Indoor Coverage Solution |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1930.0 - 1990.0 | 0.454 | Amp | GXW | |
| 24E | 1930.0 - 1990.0 | 0.482 | Amp | G7W | |
| 24E | 1930.0 - 1990.0 | 0.446 | Amp | DXW | |
| 24E | 1930.0 - 1990.0 | 0.167 | Amp | F9W |
| Power output is conducted for a single carrier. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application zRiX107EkTQPbyYP9OCEvA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ADC Telecommunications Inc 501 Shenandoah Drive Shakopee, MN 55379 United States |
Date of Grant: 10/29/2006 Application Dated: 10/27/2006 |
| Attention: Joshua Wittman , Compliance Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | F8I-DIS190AB |
| Name of Grantee: | ADC Telecommunications Inc |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Digivance 1900 MHz Indoor Coverage Solution |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1930.0 - 1990.0 | 0.454 | Amp | GXW | |
| 24E | 1930.0 - 1990.0 | 0.482 | Amp | G7W | |
| 24E | 1930.0 - 1990.0 | 0.446 | Amp | DXW | |
| 24E | 1930.0 - 1990.0 | 0.167 | Amp | F9W |
| Power output is conducted for a single carrier. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |