FCC ID F8I-DVLRCSPCS

Digivance Long-Range Coverage Solution Single Band

by ADC Telecommunications Inc

Grantee Code: F8I   Product Code: DVLRCSPCS
Latest application date: 2002-05-01

FCC ID Device Details

FCC IDF8I-DVLRCSPCS
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeF8I
Product CodeDVLRCSPCS
Applicant BusinessADC Telecommunications Inc 🇺🇸
Related Domains commscope.com
Equipment ClassDigivance Long-Range Coverage Solution Single Band
Test FirmTUV SUD America - Product Service

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1930-1990 MHzOriginal Equipment2002-05-01

Exhibits

DocumentTypeAvailableFile
manualUsers Manual2002-05-01PDF 2.9 MB
manual 1Users Manual2002-05-01PDF 2.7 MB
manual 2Users Manual2002-05-01PDF 2.8 MB
internal photoInternal Photos2002-05-01PDF 2.7 MB
internal photo 6Internal Photos2002-05-01PDF 2.7 MB
internal photos 1Internal Photos2002-05-01PDF 1.4 MB
internal photos 2Internal Photos2002-05-01PDF 2.8 MB
internal photos 3Internal Photos2002-05-01PDF 2.6 MB
internal photos 4Internal Photos2002-05-01PDF 2.3 MB
internal photos 5Internal Photos2002-05-01PDF 2.6 MB
externalExternal Photos2002-05-01PDF 2.5 MB
external photosExternal Photos2002-05-01PDF 2.9 MB
labelID Label/Location Info2002-05-01PDF 355.2 KB
report part 1Test Report2002-05-01PDF 2.9 MB
report part 3Test Report2002-05-01PDF 2.9 MB
block diagram Metadata onlyBlock DiagramPDF 86.5 KB
schematics Metadata onlySchematicsPDF 2.7 MB
operating description Metadata onlyOperational DescriptionPDF 98.2 KB
parts list tune up Metadata onlyParts List/Tune Up InfoPDF 266.5 KB

Application Information

Application IDML4jWk442PurS9SXYVHrSQ==
Final Action Date2002-05-01
Application PurposeOriginal Equipment
Applicant FRN0008274896
ModelDVLRCSPCS
Frequency Range1930-1990 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionDigivance Long-Range Coverage Solution Single Band
Responsible PartyJoshua Wittman, Compliance Engineer, Joshua.Wittman@commscope.com , 952-403-8322
AgentJoel Joel Joel, TUV Product Service, jschneider@tuvam.com , 651 583 3322
Test FirmJoel Schneider, TUV SUD America - Product Service, jschneider@tuvam.com , 651-604-4582
TCB Emailjevans@tuvam.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsDigivance 1900 MHz System Rated RF power output in watts EIRP. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of Section 2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
ML4jWk442PurS9SXYVHrSQ==2002-05-01Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1930-1990 MHz22.20E-1HzF9W24E
1930-1990 MHz22.20E-1HzDXW24E
1930-1990 MHz22.20E-1HzFXW24E

Grants

TCB Grant - Application ML4jWk442PurS9SXYVHrSQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV America, Inc.
10040 Mesa Rim Road
San Diego, CA 92121
Date of Grant: 05/01/2002

Application Dated: 05/01/2002
ADC Telecommunications Inc
501 Shenandoah Drive
Shakopee, MN 55379
 
Attention: Joshua Wittman , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F8I-DVLRCSPCS
Name of Grantee:  ADC Telecommunications Inc
Equipment Class: PCS Licensed Transmitter
Notes: Digivance Long-Range Coverage Solution Single Band
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1930.0  -  1990.0 22.2 0E-10  Hz F9W
24E 1930.0  -  1990.0 22.2 0E-10  Hz DXW
24E 1930.0  -  1990.0 22.2 0E-10  Hz FXW

Digivance 1900 MHz System Rated RF power output in watts EIRP. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of Section 2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application ML4jWk442PurS9SXYVHrSQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ADC Telecommunications Inc
501 Shenandoah Drive
Shakopee, MN 55379
United States
  Date of Grant: 05/01/2002

Application Dated: 05/01/2002
 
Attention: Joshua Wittman , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F8I-DVLRCSPCS
Name of Grantee:  ADC Telecommunications Inc
Equipment Class: PCS Licensed Transmitter
Notes: Digivance Long-Range Coverage Solution Single Band
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1930.0  -  1990.0 22.2 0E-10  Hz F9W
24E 1930.0  -  1990.0 22.2 0E-10  Hz DXW
24E 1930.0  -  1990.0 22.2 0E-10  Hz FXW

Digivance 1900 MHz System Rated RF power output in watts EIRP. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of Section 2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: