FCC ID F8I-PRSMSMRD

FlexWave Prism SMR 800/900 MHz

by ADC Telecommunications Inc

Grantee Code: F8I   Product Code: PRSMSMRD
Latest application date: 2009-09-21

FCC ID Device Details

FCC IDF8I-PRSMSMRD
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeF8I
Product CodePRSMSMRD
Applicant BusinessADC Telecommunications Inc 🇺🇸
Related Domains commscope.com
Equipment ClassFlexWave Prism SMR 800/900 MHz

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
851-869 MHzOriginal Equipment2009-09-21

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2009-09-21PDF 2.5 MB
Internal photos 1Internal Photos2009-09-21PDF 525 KB
Internal photos 2Internal Photos2009-09-21PDF 771.5 KB
Internal photos 3Internal Photos2009-09-21PDF 771.2 KB
Internal photos 4Internal Photos2009-09-21PDF 249.6 KB
Internal photos 5Internal Photos2009-09-21PDF 1.2 MB
Internal photos 6Internal Photos2009-09-21PDF 269.4 KB
External photosExternal Photos2009-09-21PDF 272.2 KB
Label LocationID Label/Location Info2009-09-21PDF 86 KB
Label locationID Label/Location Info2009-09-21PDF 86 KB
Test Report 1Test Report2009-09-21PDF 210.1 KB
Test Report 2Test Report2009-09-21PDF 597.3 KB
Confidentiality requestCover Letter(s)2009-09-21PDF 17.4 KB
Tune up informationParts List/Tune Up Info2009-09-21PDF 16.5 KB

Application Information

Application IDx5QppL7oAFC/NM1lEUfeyg==
Final Action Date2009-09-21
Application PurposeOriginal Equipment
Applicant FRN0008274896
Model-PRSMSMRD
Frequency Range851-869 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionFlexWave Prism SMR 800/900 MHz
Responsible PartyJoshua Wittman, Compliance Engineer, Joshua.Wittman@commscope.com , 952-403-8322
Technical ContactJoshua J Wittman, ADC Telecommunications Inc, joshua.wittman@adc.com , 952-403-8322
TCB EmailTCB_Admin@Intertek.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. Professional installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures.

Applications

Application IDDatePurpose
x5QppL7oAFC/NM1lEUfeyg==2009-09-21Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
851-869 MHz9.710.6ppm18K0D7W9
935-940 MHz8.670.6ppm18K0D7W9

Grants

TCB Grant - Application x5QppL7oAFC/NM1lEUfeyg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Intertek Testing Services NA, Inc.
70 Codman Hill Road
Boxborough, MA 01719
Date of Grant: 09/21/2009

Application Dated: 09/21/2009
ADC Telecommunications Inc
501 Shenandoah Drive
Shakopee, MN 55379
 
Attention: Joshua Wittman , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F8I-PRSMSMRD
Name of Grantee:  ADC Telecommunications Inc
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: FlexWave Prism SMR 800/900 MHz
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 851.0  -  869.0 9.71 0.6  PM 18K0D7W
90 935.0  -  940.0 8.67 0.6  PM 18K0D7W

Power listed is conducted. Professional installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures.

EAS Grant - Application x5QppL7oAFC/NM1lEUfeyg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ADC Telecommunications Inc
501 Shenandoah Drive
Shakopee, MN 55379
United States
  Date of Grant: 09/21/2009

Application Dated: 09/21/2009
 
Attention: Joshua Wittman , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  F8I-PRSMSMRD
Name of Grantee:  ADC Telecommunications Inc
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: FlexWave Prism SMR 800/900 MHz
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 851.0  -  869.0 9.71 0.6  PM 18K0D7W
90 935.0  -  940.0 8.67 0.6  PM 18K0D7W

Power listed is conducted. Professional installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures.



Mail To: