FCC ID FIHMPI6000A

LOCATION MONITORING SERVICE TRANSMITTER

by TransCore

Grantee Code: FIH   Product Code: MPI6000A
Latest application date: 2013-03-18

FCC ID Device Details

FCC IDFIHMPI6000A
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeFIH
Product CodeMPI6000A
Applicant BusinessTransCore 🇺🇸
Related Domains transcore.com
Equipment ClassLOCATION MONITORING SERVICE TRANSMITTER
Test FirmRogers Labs, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.25-903.75 MHzOriginal Equipment2013-03-18

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2013-03-18PDF 1.1 MB
Internal PhotosInternal Photos2013-03-18PDF 344.8 KB
External PhotosExternal Photos2013-03-18PDF 316.4 KB
Label SampleID Label/Location Info2013-03-18PDF 173.9 KB
Test Setup PhotosTest Setup Photos2013-03-18PDF 398.5 KB
Test ReportTest Report2013-03-18PDF 1.3 MB
Authorization LetterCover Letter(s)2013-03-18PDF 175.1 KB
Confidential LetterCover Letter(s)2013-03-18PDF 202.1 KB
Submittal LetterCover Letter(s)2013-03-18PDF 87.5 KB
RF ExposureRF Exposure Info2013-03-18PDF 62.9 KB
Tuneup ProcedureParts List/Tune Up Info2013-03-18PDF 3.8 KB

Application Information

Application IDAS2Sw2t69ARXSvtU+clY1A==
Final Action Date2013-03-18
Application PurposeOriginal Equipment
Applicant FRN0007067481
ModelMPI6000A
Frequency Range902.25-903.75 MHz
Equipment ClassLMS - Part 90 Location & Monitoring Transmitter
Device DescriptionLOCATION MONITORING SERVICE TRANSMITTER
Responsible PartyChris Wilson, Quality Assurance Supervisor, chris.wilson@transcore.com , 505 856-8178
Test FirmScot Rogers, Rogers Labs, Inc., rogers@pixius.net , 913-837-3214
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. This device must be professionally installed. The peak radiated output power, including antenna gain and cable loss, must not exceed 30 W ERP. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 81 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. The maximum antenna height above ground for non-multilateration LMS systems is 15 meters. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
AS2Sw2t69ARXSvtU+clY1A==2013-03-18Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
902.25-903.75 MHz22.5ppmN0N90.353
910-921.5 MHz22.5ppmN0N90.353
911.75-919.75 MHz22.5ppm610KL1D90.353
912.75-918.75 MHz22.5ppm815KL1D90.353
912.75-918.75 MHz22.5ppm1M71L1D90.353
914.75-916.75 MHz22.5ppm2M82L1D90.353

Grants

TCB Grant - Application AS2Sw2t69ARXSvtU+clY1A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 03/18/2013

Application Dated: 03/18/2013
TransCore
Amtech Technology Center
8600 Jefferson Street, NE
Albuquerque, NM 87113
 
Attention: Chris Wilson , Quality Assurance Supervisor

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  FIHMPI6000A
Name of Grantee:  TransCore
Equipment Class: Part 90 Location & Monitoring Transmitter
Notes: LOCATION MONITORING SERVICE TRANSMITTER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.353 902.25  -  903.75 2.0 2.5  PM N0N
90.353 910.0  -  921.5 2.0 2.5  PM N0N
90.353 911.75  -  919.75 2.0 2.5  PM 610KL1D
90.353 912.75  -  918.75 2.0 2.5  PM 815KL1D
90.353 912.75  -  918.75 2.0 2.5  PM 1M71L1D
90.353 914.75  -  916.75 2.0 2.5  PM 2M82L1D

Power listed is conducted. This device must be professionally installed. The peak radiated output power, including antenna gain and cable loss, must not exceed 30 W ERP. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 81 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. The maximum antenna height above ground for non-multilateration LMS systems is 15 meters. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application AS2Sw2t69ARXSvtU+clY1A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

TransCore
Amtech Technology Center 8600 Jefferson Street, NE
Albuquerque, NM 87113
United States
  Date of Grant: 03/18/2013

Application Dated: 03/18/2013
 
Attention: Chris Wilson , Quality Assurance Supervisor

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  FIHMPI6000A
Name of Grantee:  TransCore
Equipment Class: Part 90 Location & Monitoring Transmitter
Notes: LOCATION MONITORING SERVICE TRANSMITTER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90.353 902.25  -  903.75 2.0 2.5  PM N0N
90.353 910.0  -  921.5 2.0 2.5  PM N0N
90.353 911.75  -  919.75 2.0 2.5  PM 610KL1D
90.353 912.75  -  918.75 2.0 2.5  PM 815KL1D
90.353 912.75  -  918.75 2.0 2.5  PM 1M71L1D
90.353 914.75  -  916.75 2.0 2.5  PM 2M82L1D

Power listed is conducted. This device must be professionally installed. The peak radiated output power, including antenna gain and cable loss, must not exceed 30 W ERP. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 81 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. The maximum antenna height above ground for non-multilateration LMS systems is 15 meters. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: