FCC ID FIHMPRXPT90V5

Location and Monitoring Service Interrogator

by TransCore

Grantee Code: FIH   Product Code: MPRXPT90V5
Latest application date: 2022-05-24

FCC ID Device Details

FCC IDFIHMPRXPT90V5
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeFIH
Product CodeMPRXPT90V5
Applicant BusinessTransCore 🇺🇸
Related Domains transcore.com
Equipment ClassLocation and Monitoring Service Interrogator
Test FirmRogers Labs, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.25-903.75 MHzOriginal Equipment2022-05-24

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2022-05-24PDF 5.4 MB
Internal Photos 1Internal Photos2022-05-24PDF 4 MB
Internal Photos 2Internal Photos2022-05-24PDF 2.4 MB
External PhotosExternal Photos2022-05-24PDF 1.5 MB
Label SampleID Label/Location Info2022-05-24PDF 267.7 KB
Test Setup PhotosTest Setup Photos2022-05-24PDF 1.8 MB
Test ReportTest Report2022-05-24PDF 1.9 MB
Agent AuthorizationCover Letter(s)2022-05-24PDF 89.6 KB
Confidentiality RequestCover Letter(s)2022-05-24PDF 145.4 KB
Submittal LetterCover Letter(s)2022-05-24PDF 84.8 KB
RF ExposureRF Exposure Info2022-05-24PDF 100.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 114.4 KB
Schematics Metadata onlySchematicsPDF 1.2 MB
Operational Description Metadata onlyOperational DescriptionPDF 103.1 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 1.3 MB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 71.2 KB

Application Information

Application IDRw9oXcama1P5YhfZe4RHjw==
Final Action Date2022-05-24
Application PurposeOriginal Equipment
Applicant FRN0006083745
ModelMPRXPT90V5
Frequency Range902.25-903.75 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionLocation and Monitoring Service Interrogator
Responsible PartyDale Scott, VP of Engineering and Manufacturing, dale.scott@transcore.com , 505 856-8178
Test FirmScot Rogers, Rogers Labs, Inc., rogers@pixius.net , 913-837-3214
TCB Emailtei@timcoengr.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power rated conducted output power. The antenna(s) used for this transmitter must be installed and operated so as to provide a separation distance of at least 81 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

Applications

Application IDDatePurpose
Rw9oXcama1P5YhfZe4RHjw==2022-05-24Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
902.25-903.75 MHz20.4ppm110KN0N9
910-921.5 MHz20.4ppm110KN0N9
911.75-919.75 MHz20.4ppm567KL1D9

Grants

TCB Grant - Application Rw9oXcama1P5YhfZe4RHjw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 05/24/2022

Application Dated: 05/24/2022
TransCore
Amtech Technology Center
8600 Jefferson Street, NE
Albuquerque, NM 87113
 
Attention: Dale Scott , VP of Engineering and Manufacturing

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  FIHMPRXPT90V5
Name of Grantee:  TransCore
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Location and Monitoring Service Interrogator
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 902.25  -  903.75 2.0 0.4  PM 110KN0N
90 910.0  -  921.5 2.0 0.4  PM 110KN0N
90 911.75  -  919.75 2.0 0.4  PM 567KL1D

Output Power rated conducted output power. The antenna(s) used for this transmitter must be installed and operated so as to provide a separation distance of at least 81 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

EAS Grant - Application Rw9oXcama1P5YhfZe4RHjw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

TransCore
Amtech Technology Center 8600 Jefferson Street, NE
Albuquerque, NM 87113
United States
  Date of Grant: 05/24/2022

Application Dated: 05/24/2022
 
Attention: Dale Scott , VP of Engineering and Manufacturing

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  FIHMPRXPT90V5
Name of Grantee:  TransCore
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Location and Monitoring Service Interrogator
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 902.25  -  903.75 2.0 0.4  PM 110KN0N
90 910.0  -  921.5 2.0 0.4  PM 110KN0N
90 911.75  -  919.75 2.0 0.4  PM 567KL1D

Output Power rated conducted output power. The antenna(s) used for this transmitter must be installed and operated so as to provide a separation distance of at least 81 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.