FCC ID G2X-66004A
Fall Detector
by Tunstall Healthcare (UK) Limited
Grantee Code: G2X Product Code: 66004A
Latest application date: 2004-02-02
FCC ID Device Details
| FCC ID | G2X-66004A |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | G2X |
| Product Code | 66004A |
| Applicant Business | Tunstall Healthcare (UK) Limited 🇬🇧 |
| Related Domains | |
| Equipment Class | Fall Detector |
| Test Firm | TRL EMC Limited |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 312 MHz | Original Equipment | 2004-02-02 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| D6607xxA0 | Users Manual | 2004-02-02 | PDF 182.6 KB |
| AddonPCBtrackside | Internal Photos | 2004-02-02 | PDF 51.8 KB |
| MainPCBcomponentside | Internal Photos | 2004-02-02 | PDF 73.3 KB |
| MainPCBunderside | Internal Photos | 2004-02-02 | PDF 63 KB |
| addonPCBcomponentside | Internal Photos | 2004-02-02 | PDF 51.8 KB |
| creamcaseback | External Photos | 2004-02-02 | PDF 25.5 KB |
| creamcasefront | External Photos | 2004-02-02 | PDF 25.4 KB |
| greycaseback | External Photos | 2004-02-02 | PDF 19.3 KB |
| greycasefront | External Photos | 2004-02-02 | PDF 21.3 KB |
| LABEL | ID Label/Location Info | 2004-02-02 | PDF 96.2 KB |
| labelposition | ID Label/Location Info | 2004-02-02 | PDF 32.8 KB |
| testsetup | Test Setup Photos | 2004-02-02 | PDF 56.3 KB |
| ru10975206 | Test Report | 2004-02-02 | PDF 558.4 KB |
| agency | Cover Letter(s) | 2004-02-02 | PDF 222 KB |
| confidentiality | Cover Letter(s) | 2004-02-02 | PDF 266.8 KB |
| labelling | Cover Letter(s) | 2004-02-02 | PDF 213.6 KB |
| manufacturers | Cover Letter(s) | 2004-02-02 | PDF 220.5 KB |
| testsetup | jpeg | 2004-02-02 | PDF 56.3 KB |
| 312FallDet Metadata only | Block Diagram | PDF 31.3 KB | |
| SA6601CCTA3 Metadata only | Schematics | PDF 62.1 KB | |
| SA6610CCTA1 Metadata only | Schematics | PDF 75.7 KB | |
| artwork Metadata only | Schematics | PDF 3.1 MB | |
| CCTdesc312 Metadata only | Operational Description | PDF 102.7 KB | |
| parts Metadata only | Parts List/Tune Up Info | PDF 1.3 MB |
Application Information
| Application ID | bvVz5Ke8C2QMuMfevN8z2w== |
|---|---|
| Final Action Date | 2004-02-02 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0008182396 |
| Model | 66004A |
| Frequency Range | 312 MHz |
| Equipment Class | DSC - Part 15 Security/Remote Control Transmitter |
| Device Description | Fall Detector |
| Responsible Party | Mark Jennings, Chief Engineer, mark.jennings@tunstall.com |
| Technical Contact | Richard Martin, Tunstall Telecom Ltd, r_martin@tunstall.co.uk |
| Non-Technical Contact | Richard Nadin, Tunstall Telecom Ltd, r_nadin@tunstall.co.uk |
| Test Firm | Neil Roche, TRL EMC Limited, neil.roche@trlcompliance.com |
| TCB Email | paul.darragh@trlcompliance.com |
| TCB Scope | A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| bvVz5Ke8C2QMuMfevN8z2w== | 2004-02-02 | Original Equipment |
Equipment Authorization
| Frequency | Rules |
|---|---|
| 312 MHz | 15.231 |
Grants
TCB Grant - Application bvVz5Ke8C2QMuMfevN8z2w==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Element Materials Technology Warwick Ltd Rothwell Road Warwick Warwick, CV34 5JX United Kingdom |
Date of Grant: 02/02/2004 Application Dated: 01/29/2004 |
| Tunstall Healthcare (UK) Limited |
| Whitley Lodge, Whitley Bridge |
| Yorkshire, DN140HR, United Kingdom |
| Attention: Mark Jennings , Chief Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | G2X-66004A |
| Name of Grantee: | Tunstall Healthcare (UK) Limited |
| Equipment Class: | Part 15 Security/Remote Control Transmitter |
| Notes: | Fall Detector |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15.231 | 312.0 - 312.0 |
EAS Grant - Application bvVz5Ke8C2QMuMfevN8z2w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Tunstall Healthcare (UK) Limited Whitley Lodge, Whitley Bridge Yorkshire, DN140HR, United Kingdom |
Date of Grant: 02/02/2004 Application Dated: 01/29/2004 |
| Attention: Mark Jennings , Chief Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | G2X-66004A |
| Name of Grantee: | Tunstall Healthcare (UK) Limited |
| Equipment Class: | Part 15 Security/Remote Control Transmitter |
| Notes: | Fall Detector |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15.231 | 312.0 - 312.0 |
| Mail To: |