FCC ID GKRVT-5D
Dual Band Tri Mode PCS/AMPS/CDMA Cellular Phone
by Compal Electronics Inc
Grantee Code: GKR Product Code: VT5D
Latest application date: 2004-08-27
FCC ID Device Details
| FCC ID | GKRVT-5D |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | GKR |
| Product Code | VT5D |
| Applicant Business | Compal Electronics Inc 🇹🇼 |
| Related Domains | |
| Equipment Class | Dual Band Tri Mode PCS/AMPS/CDMA Cellular Phone |
| Test Firm | Compliance Certification Services Inc |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.04-848.97 MHz | Original Equipment | 2004-08-27 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2004-08-27 | PDF 249 KB |
| Internal Photos | Internal Photos | 2004-08-27 | PDF 2.2 MB |
| Adapter and Adapter External Photos | External Photos | 2004-08-27 | PDF 2 MB |
| External Photos | External Photos | 2004-08-27 | PDF 2.3 MB |
| FCC ID Label | ID Label/Location Info | 2004-08-27 | PDF 63 KB |
| Setup Photos | Test Setup Photos | 2004-08-27 | PDF 488.1 KB |
| Test Report | Test Report | 2004-08-27 | PDF 1.5 MB |
| report attachment | Test Report | 2004-08-27 | PDF 17.1 KB |
| Attestation Statement | Cover Letter(s) | 2004-08-27 | PDF 157.7 KB |
| Request for Confidentiality | Cover Letter(s) | 2004-08-27 | PDF 237.7 KB |
| TCB QA | Cover Letter(s) | 2004-08-27 | PDF 7.6 KB |
| SAR Attachment 1 | RF Exposure Info | 2004-08-27 | PDF 530.5 KB |
| SAR Attachment 2 | RF Exposure Info | 2004-08-27 | PDF 2.7 MB |
| SAR Attachment 3 | RF Exposure Info | 2004-08-27 | PDF 1.3 MB |
| SAR Attachment 4 | RF Exposure Info | 2004-08-27 | PDF 1.4 MB |
| SAR Attachment 5 | RF Exposure Info | 2004-08-27 | PDF 2.4 MB |
| SAR Attachment 6 | RF Exposure Info | 2004-08-27 | PDF 330.5 KB |
| SAR Attachment 7 | RF Exposure Info | 2004-08-27 | PDF 345.3 KB |
| SAR Report | RF Exposure Info | 2004-08-27 | PDF 1.5 MB |
| Block Diagram Metadata only | Block Diagram | PDF 66.4 KB | |
| Schematics Metadata only | Schematics | PDF 375.5 KB | |
| Technical Description Metadata only | Operational Description | PDF 32.1 KB | |
| Theory of Operation Metadata only | Operational Description | PDF 126.9 KB | |
| Antenna Information Metadata only | Parts List/Tune Up Info | PDF 1.3 MB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 53.5 KB | |
| Tuneup Procedure Metadata only | Parts List/Tune Up Info | PDF 309.1 KB |
Application Information
| Application ID | PH1gCs+t3tki5vWrJB/n7Q== |
|---|---|
| Final Action Date | 2004-08-27 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0020269494 |
| Model | VT-5D |
| Frequency Range | 824.04-848.97 MHz |
| Equipment Class | PCE - PCS Licensed Transmitter held to ear |
| Device Description | Dual Band Tri Mode PCS/AMPS/CDMA Cellular Phone |
| Responsible Party | Joyce Ting, Senior RF Regulatory Compliance Engineer, joyce_ting@compal.com |
| Agent | Thu Thu Thu, Compliance Certification Services, tchan@ccsemc.com |
| Test Firm | Steve Cheng, Compliance Certification Services Inc, scheng@ccsemc.com |
| TCB Email | mkuo@ccsemc.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output is ERP for Part 22 and EIRP for Part 24. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: AMPS Part 22 ¡V Head: 1.09W/kg; Body-worn: 1.23W/kg; CDMA Part 22 - Head: 0.665 W/kg; Body-worn: 0.726 W/kg; PCS Part 24 - Head: 0.869 W/kg; Body-worn: 0.417 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| PH1gCs+t3tki5vWrJB/n7Q== | 2004-08-27 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application PH1gCs+t3tki5vWrJB/n7Q==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 08/27/2004 Application Dated: 08/27/2004 |
| Compal Electronics Inc |
| No.581 & 581-1, Ruiguang Rd., Neihu District, |
| Taipei city,, 11492 Taiwan |
| Attention: Joyce Ting , Senior RF Regulatory Compliance Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | GKRVT-5D |
| Name of Grantee: | Compal Electronics Inc |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | Dual Band Tri Mode PCS/AMPS/CDMA Cellular Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1851.25 - 1908.75 | 0.871 | 2.5 PM | 1M27F9W | |
| 22H | 824.7 - 848.31 | 0.5623 | 2.5 PM | 1M26F9W | |
| BC | 22H | 824.04 - 848.97 | 0.3388 | 2.5 PM | 39K3F8W |
| BC | 22H | 824.04 - 848.97 | 0.3388 | 2.5 PM | 39K3F1D |
| Output is ERP for Part 22 and EIRP for Part 24. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: AMPS Part 22 ¡V Head: 1.09W/kg; Body-worn: 1.23W/kg; CDMA Part 22 - Head: 0.665 W/kg; Body-worn: 0.726 W/kg; PCS Part 24 - Head: 0.869 W/kg; Body-worn: 0.417 W/kg. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
EAS Grant - Application PH1gCs+t3tki5vWrJB/n7Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Compal Electronics Inc No.581 & 581-1, Ruiguang Rd., Neihu District, Taipei city,, 11492 Taiwan |
Date of Grant: 08/27/2004 Application Dated: 08/27/2004 |
| Attention: Joyce Ting , Senior RF Regulatory Compliance Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | GKRVT-5D |
| Name of Grantee: | Compal Electronics Inc |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | Dual Band Tri Mode PCS/AMPS/CDMA Cellular Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1851.25 - 1908.75 | 0.871 | 2.5 PM | 1M27F9W | |
| 22H | 824.7 - 848.31 | 0.5623 | 2.5 PM | 1M26F9W | |
| BC | 22H | 824.04 - 848.97 | 0.3388 | 2.5 PM | 39K3F8W |
| BC | 22H | 824.04 - 848.97 | 0.3388 | 2.5 PM | 39K3F1D |
| Output is ERP for Part 22 and EIRP for Part 24. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna and the user body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: AMPS Part 22 ¡V Head: 1.09W/kg; Body-worn: 1.23W/kg; CDMA Part 22 - Head: 0.665 W/kg; Body-worn: 0.726 W/kg; PCS Part 24 - Head: 0.869 W/kg; Body-worn: 0.417 W/kg. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
| Mail To: |