FCC ID GM332DTRX7425
Data Radio Max output power 32 milliwatts This device may only be marketed for use in teklogix manufactured devices and must be professionally installed.
by Psion Inc
Grantee Code: GM3 Product Code: 32DTRX7425
Latest application date: 1997-02-06
FCC ID Device Details
| FCC ID | GM332DTRX7425 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | GM3 |
| Product Code | 32DTRX7425 |
| Applicant Business | Psion Inc 🇺🇸 |
| Related Domains | |
| Equipment Class | Data Radio Max output power 32 milliwatts This device may only be marketed for use in teklogix manufactured devices and must be professionally installed. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 1997-02-06 |
Application Information
| Application ID | X68FTUu+OWKQ2qEis9QQ7A== |
|---|---|
| Final Action Date | 1997-02-06 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0006929947 |
| Model | 32DTRX7425 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | Data Radio Max output power 32 milliwatts This device may only be marketed for use in teklogix manufactured devices and must be professionally installed. |
| Responsible Party | Sada Dharwarkar, sada.dharwarkar@motorolasolutions.com |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | No |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| X68FTUu+OWKQ2qEis9QQ7A== | 1997-02-06 | Original Equipment |
Grants
TCB Grant - Application X68FTUu+OWKQ2qEis9QQ7A==
This application does not exist.
EAS Grant - Application X68FTUu+OWKQ2qEis9QQ7A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Psion Inc One Motorola Plaza Holtsville, NY United States |
Date of Grant: 02/06/1997 Application Dated: 10/30/1996 |
| Attention: Sada Dharwarkar |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | GM332DTRX7425 |
| Name of Grantee: | Psion Inc |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Data Radio Max output power 32 milliwatts This device may only be marketed for use in teklogix manufactured devices and must be professionally installed. |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 37 | 15C | 2412.0 - 2462.0 |
| 37: | This device has shown compliance with new rules adopted under Docket 87-389 and is not affected by Section 15.37, transition rule. |
| Mail To: |
| Tri Luu, |
| UltraTech Engineering Labs Inc. |
| 33-4181 Sladeview Crescent |
| Mississauga, L5L 5R2 |
| Canada |